DS215UCIAG1AZZ05A

/ 4.9
1001 reviews | Need a Specific Revision?
DS215UCIAG1AZZ05A is a GE Vernova Legacy UCI Board Assembly for legacy uci board assembly replacement and installed-system maintenance.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for DS215UCIAG1AZZ05A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS215UCIAG1AZZ05A

  • Manufacturer:
    General Electric
  • Part Number:
    DS215UCIAG1AZZ05A
  • Product Family:
    GE Mark VIe Distributed I/O
  • Product Type:
    Legacy UCI Board Assembly
  • Stock:
    1
  • Hardware function:
    Legacy UCI Board Assembly
  • Control platform:
    Legacy GE drive and turbine control
  • Interface scope:
    Board- or module-specific interfaces for the Legacy GE drive and turbine control installation
  • Primary application:
    Legacy UCI Board Assembly replacement and installed-system maintenance
  • Hardware identity:
    DS215UCIAG1AZZ05A
  • Replacement basis:
    Exact hardware and installed configuration match
  • Commissioning checks:
    Power, grounding, wiring, diagnostics and channel response
  • Documentation basis:
    OEM-authored family reference plus installed nameplate
  • Weight:
    1.45 kg
  • Estimated shipping dimensions:
    8x18.5x26.1cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Hardware Data Compatibility Commissioning Installation Check

Product overview:

  • Legacy UCI Board Assembly
  • Legacy GE drive and turbine control
  • Legacy UCI Board Assembly replacement and installed-system maintenance

DS215UCIAG1AZZ05A provides board- or module-specific interfaces for the legacy ge drive and turbine control installation.

Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.

Apter Power can provide DS215UCIAG1AZZ05A for quotation and technical review.

Hardware data:

  • Exact identity: DS215UCIAG1AZZ05A
  • Function: Legacy UCI Board Assembly
  • Platform: Legacy GE drive and turbine control

Board- or module-specific interfaces for the Legacy GE drive and turbine control installation

Compatibility review:

  • Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
  • Compare connectors, terminal assignments and configured options
  • Use an engineered migration when revisions are not interchangeable

DS215UCIAG1AZZ05A should be matched to the complete installed control assembly.

Commissioning checks:

  • Verify power and protective isolation
  • Confirm grounding, shielding and field wiring
  • Test diagnostics and functional response

Record baseline results for DS215UCIAG1AZZ05A before returning the machine to service.

Installation check:

  • Photograph the original hardware and settings
  • Follow site lockout/tagout and ESD controls
  • Inspect connectors, torque and ventilation

Do not energize DS215UCIAG1AZZ05A until wiring and configuration reviews are complete.

Description

DS215UCIAG1AZZ05A is a GE Vernova Legacy UCI Board Assembly associated with the Legacy GE drive and turbine control platform. Its documented role is legacy uci board assembly replacement and installed-system maintenance, with board- or module-specific interfaces for the legacy ge drive and turbine control installation.

DS215UCIAG1AZZ05A must be treated as one complete hardware and configuration reference. The board or module, terminal arrangement, firmware and connected control hardware must match the installed cabinet drawings; a similar family code does not establish electrical or functional interchangeability.

Before installing DS215UCIAG1AZZ05A, isolate power, photograph the existing nameplate and connectors, record rack position and jumper settings, compare terminal assignments, and verify power, grounding, field wiring and diagnostics during commissioning.

Alternative Names
DS215UCIAG1AZZ05A GE Vernova DS215UCIAG1AZZ05A DS215UCIAG1AZZ05A Legacy UCI Board Assembly DS215UCIAG1AZZ05A replacement module DS215UCIAG1AZZ05A spare part DS215UCIAG1AZZ05A datasheet DS215UCIAG1AZZ05A industrial control component 7 DS215UCIAG1AZZ05A industrial control component 8
Technical notes
DS215UCIAG1AZZ05A is the exact legacy uci board assembly reference for the Legacy GE drive and turbine control installation. Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which installed details must match before replacing DS215UCIAG1AZZ05A?
Match the complete DS215UCIAG1AZZ05A nameplate, hardware revision, firmware, rack or cabinet position, connectors and terminal assignments.
How should the interface for DS215UCIAG1AZZ05A be verified?
Use the system drawings to verify board- or module-specific interfaces for the legacy ge drive and turbine control installation, including signal type, polarity, reference potential and grounding.
What should be checked before applying power to DS215UCIAG1AZZ05A?
Confirm supply voltage, protective devices, connector keying, jumper positions, field isolation and cabinet grounding before energizing.
How is DS215UCIAG1AZZ05A commissioned after installation?
Check the legacy uci board assembly replacement and installed-system maintenance function channel by channel and compare diagnostics, feedback and commanded states with the original configuration.
Can a similar family board replace DS215UCIAG1AZZ05A?
Not by part-family similarity alone. Electrical interfaces, firmware, revision, options and configured function must be reviewed as one replacement package.
What manual should be used for DS215UCIAG1AZZ05A?
Use the product-specific Apter Power datasheet together with the latest applicable OEM system manual and the installed cabinet drawings.
What information is needed for a quotation for DS215UCIAG1AZZ05A?
Provide clear front and rear nameplate photos, complete suffixes, quantity, installed platform, failure symptoms and delivery destination.
How should a stored spare for DS215UCIAG1AZZ05A be evaluated?
Inspect packaging and connectors, review storage history, verify firmware and revision, and perform controlled bench or cabinet tests before return to service.