GE,IS210BPPBH2BMD
GE,IS210BPPBH2BMD
GE,IS210BPPBH2BMD
GE,IS210BPPBH2BMD
GE,IS210BPPBH2BMD
GE,IS210BPPBH2BMD
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

IS210BPPBH2BMD

/ 4.9
1001 reviews | Need a Specific Revision?
The GE IS210BPPBH2BMD is a genuine heavy-duty backplane power processor board (BPPB) designed specifically for Speedtronic Mark VI gas and steam turbine control systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for IS210BPPBH2BMD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IS210BPPBH2BMD

  • Manufacturer:
    General Electric
  • Part Number:
    IS210BPPBH2BMD
  • Product Family:
    GE Mark VIe Distributed I/O
  • Product Type:
    Backplane Power Processor Board
  • Stock:
    1
  • Digital I/O:
    32 channels
  • Analog Inputs:
    16 channels
  • Pulse Inputs:
    4 channels
  • Input Voltage:
    24V DC ±10%
  • Isolation:
    1500V AC
  • Operating Temperature:
    -40°C to +70°C
  • Storage Temperature:
    -50°C to +85°C
  • Humidity:
    0-95% non-condensing
  • Weight:
    0.05 kg
  • Estimated shipping dimensions:
    11x7.5x2.2cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Monitoring & Control Compatibility & Interoperability

Features:

  • Dedicated Backplane Power Processing Architecture
  • Passive Overcurrent & Voltage Spike Suppression
  • Keyed High-Density Connector Integration
The General Electric IS210BPPBH2BMD functions as a centralized power management highway on the rack tier, efficiently conditioning and distributing vital low-ripple control voltages directly to downstream logic processors.

Equipped with robust, fast-acting onboard fuses and varistors, the General Electric IS210BPPBH2BMD intercepts industrial electrical surges, safely isolating the backplane and preventing catastrophic cross-board damage.

Designed with proprietary multi-pin configurations and a long-narrow mating header, the General Electric IS210BPPBH2BMD ensures mistake-proof mechanical alignment during cabinet installation or field maintenance cycles.

The IS210BPPBH2BMD General Electric Mark VI Speedtronic Backplane Power Processor Board may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IS210BPPBH2BMD Mark VI Speedtronic Backplane Power Processor Board Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IS210BPPBH2BMD Mark VI Speedtronic Backplane Power Processor Board

General

  • Manufacturer General Electric
  • Model IS210BPPBH2BMD
  • Condition New Original ready stock
  • Product Family IS210BPPBH2BKD,IS210BPPBH2BLD,IS210BPPCH1ACA
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Main Turbine Control Panels: Operating as the foundational power processing layout inside the Speedtronic Mark VI turbine cabinets for power utilities.
  • Combined-Cycle Power Plants: Managing stable power routing for rack components overseeing gas turbine and steam turbine governors.
  • Heavy Automated Process Control: Deployed in demanding manufacturing environments where continuous backplane voltage regulation is required.
  • Legacy Control System Life Extension: Used as a vital, direct-replacement spare to maintain and extend the operational lifecycle of existing Mark VI infrastructure.
  • Local Voltage Line Verification: Utilizing board-edge LEDs to give maintenance crews immediate feedback on backplane power rail status.
  • Localized Short-Circuit Isolation: Segregating power faults via dedicated on-board fuses to ensure a localized hardware issue does not trip adjacent tiers.
  • High-Frequency Ripple Filtering: Attenuating upstream power grid noise through high-grade capacitor networks to provide clean logic lines for control microprocessors.
  • Low-Impedance Power Routing: Delivering optimized copper traces to minimize voltage drops across heavy-duty industrial backplane structures.
  • Exact Mark VI Chassis Form Factor: Specifically tailored to align with GE’s standard rack dimensions, standoff spacings, and card guide rails.
  • Keyed Proprietary Header Mating: Incorporating specialized multi-position female plugs and a long-narrow connector to eliminate human mating errors during field swap-outs.
  • Cross-Revision Functional Alignment: Designed to perfectly replace older functional versions within the BPPB series without requiring changes to the backplane housing.
  • Balanced Dual-Rail Distribution Capability: Functioning as the reliable circuit highway necessary to distribute multiple voltage lines evenly across adjacent backplane slots.
Description
The General Electric IS210BPPBH2BMD is a foundational hardware asset within the GE Speedtronic Mark VI turbine control architecture. Formally designated as the Backplane Power Processor Board (BPPB), this critical card is engineered to bridge the gap between primary cabinet power distribution and localized rack-level processing electronics. Installed directly into the dedicated backplane panel slots, it manages the conditioning and routing of the specific voltage lines required by adjacent computational modules.

As a dedicated General Electric IS210BPPBH2BMD board, its electrical design focuses on high-reliability voltage smoothing and localized logic support. The circuit layout is heavily populated with industrial-grade fuses, filtering capacitors, and metal oxide varistors (MOVs) designed to suppress voltage transients. By filtering incoming power before it reaches the main control bus, the board prevents industrial electromagnetic interference (EMI) and power sags from disrupting the critical real-time processing tasks of the turbine control system.

Mechanically, the General Electric IS210BPPBH2BMD interfaces with the backplane infrastructure through high-density multi-pin connectors, including a distinctively configured long, narrow plug interface. This specialized design ensures perfect alignment and optimal low-impedance contact within standard GE cabinet tiers. Operating entirely via passive convection, the board eliminates mechanical fan failure risks, providing a solid-state framework that maintains continuous operation under high thermal stress in power plant environments.
Alternative Names
1S210BPPBH2BMD IS2I0BPPBH2BMD IS21OBPPBH2BMD 1S2IOBPPBH2BMD IS210BPPBH2BKD IS210BPPBH2BLD IS210BPPCH1ACA
Technical notes
The General Electric IS210BPPBH2BMD serves as a hardwired Backplane Power Processor Board that provides physical power filtering and signal routing paths without requiring independent firmware runtime adjustments in the GE ToolboxST application. Covered in a specialized, protective conformal coating, the General Electric IS210BPPBH2BMD is fully shielded against conductive airborne dust, localized humidity, and chemical contaminants typical of industrial control rooms.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does the General Electric IS210BPPBH2BMD involve software configuration or IO board mapping?
No. The General Electric IS210BPPBH2BMD functions as a hardware-level power distribution and connection processor utility. It is a true hardware drop-in module that requires zero software variable mapping or firmware flashing during field replacement.
What are the exact visual indicators available on the General Electric IS210BPPBH2BMD for rapid troubleshooting?
The General Electric IS210BPPBH2BMD features onboard, edge-mounted diagnostic LEDs. These LEDs provide instant visual verification of correct voltage routing across the backplane traces, allowing technicians to verify circuit health at a glance without manual probing.
What types of environments benefit most from the conformal coating on the General Electric IS210BPPBH2BMD?
The industrial conformal coating on the General Electric IS210BPPBH2BMD is vital for heavy-duty setups like coal-fired power utilities, chemical processing facilities, and offshore platforms, where it seals the traces against conductive carbon dust, high humidity, and corrosive chemical vapors.
Can the General Electric IS210BPPBH2BMD be replaced while the core turbine is running?
Because the General Electric IS210BPPBH2BMD routes essential control power to the localized processor rack, replacing this specific board typically requires isolating power to that specific chassis tier. Always refer to your plant's standard Speedtronic Mark VI maintenance and safety protocols before removal.
How does the fanless design of the General Electric IS210BPPBH2BMD impact its long-term reliability in industrial cabinets?
By using a purely solid-state, passive cooling layout, the General Electric IS210BPPBH2BMD avoids the mechanical wear and dust-clogging vulnerabilities associated with cooling fans, resulting in a significantly higher Mean Time Between Failures (MTBF).

Product Browsing History