GE Vernova UR6EH is a plug-in module configuration for GE Multilin Universal Relay hardware identified by the full suffix UR6EH. It is intended for exact-configuration maintenance in the documented system.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for UR6EH
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for UR6EH

  • Manufacturer:
    General Electric
  • Part Number:
    UR6EH
  • Product Family:
    GE Multilin
  • Product Type:
    Protection Relay Plug-in Module
  • Stock:
    1
  • Hardware family:
    Universal Relay
  • Module identifier:
    UR6EH
  • Installation form:
    Plug-in relay module
  • System domain:
    Power-system protection
  • Backplane interface:
    UR chassis
  • Field connection:
    Slot-specific terminals
  • Firmware relationship:
    Relay release dependent
  • Order-code control:
    Position-sensitive option string
  • Replacement basis:
    Complete relay order code
  • Commissioning evidence:
    Relay setting file and diagnostics
  • Service state:
    De-energized control and CT/VT circuits
  • Application scope:
    Protection, control and monitoring
  • Tariff Code:
    8538909190
  • Country of origin:
    Canada
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Compatibility Safety Programming

Features:

  • The ordered configuration is a plug-in module configuration for GE Multilin Universal Relay hardware identified by the full suffix UR6EH.
  • In service, the hardware provides the module function encoded by the UR order code within a compatible Universal Relay chassis.
  • Correct selection depends on relay model, slot assignment, order-code option, firmware generation, terminal mapping and chassis hardware revision.
The current order is identified by the complete UR6EH marking and its documented relationship to GE Multilin Universal Relay.

The hardware is used in maintenance of protection, control and monitoring relays used on electrical power systems, where it provides the module function encoded by the UR order code within a compatible Universal Relay chassis.

Installation planning must account for relay model, slot assignment, order-code option, firmware generation, terminal mapping and chassis hardware revision. UR option letters are position-sensitive; verify the full relay order code and slot map before inserting UR6EH

Availability is confirmed against the complete model, revision, quantity and delivery destination.
Verified resources for GE Vernova UR6EH:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Supports maintenance of protection, control and monitoring relays used on electrical power systems without changing the documented host architecture.
  • Serves maintenance teams restoring the original GE Multilin Universal Relay signal, control or power path.
  • Fits modernization planning when the existing installation must remain operational while a long-term migration is evaluated.
  • System matching is governed by relay model, slot assignment, order-code option, firmware generation, terminal mapping and chassis hardware revision.
  • The surrounding GE Multilin Universal Relay hardware must retain the connector, addressing and project relationships documented for this order code.
  • A cross-family or partial-number substitution is not approved unless the OEM service record explicitly defines it against other UR6xx option modules.
  • De-energize all applicable power and field circuits and apply the OEM procedure before this hardware is removed.
  • The high-risk selection point is that UR option letters are position-sensitive; verify the full relay order code and slot map before inserting UR6EH
  • Protective grounding, interlocks and fail-safe behavior must be proven at system level before normal service resumes.
  • Configuration data belongs to the installed GE Multilin Universal Relay project and should be backed up before hardware removal.
  • Revision, firmware, address and option settings must be reviewed together with the complete order number.
  • Commissioning should load only a validated project or parameter set and then confirm the intended operating state.
Description
GE Vernova UR6EH is engineered as a plug-in module configuration for GE Multilin Universal Relay hardware identified by the full suffix UR6EH. The complete order identity ties this hardware to the GE Multilin Universal Relay platform rather than to a visually similar device.

In operation, it provides the module function encoded by the UR order code within a compatible Universal Relay chassis. Its principal connection boundary is the keyed relay slot, internal backplane and field terminals associated with the installed UR model, making the unit suitable for maintenance of protection, control and monitoring relays used on electrical power systems.

Before ordering, verify relay model, slot assignment, order-code option, firmware generation, terminal mapping and chassis hardware revision. UR option letters are position-sensitive; verify the full relay order code and slot map before inserting UR6EH
Alternative Names
UR6EH GE Vernova UR6EH UR6EH Protection Relay Plug-in Module GE Vernova Universal Relay Replacement Module UR6EH GE Multilin Universal Relay GE Vernova UR6EH spare GE Vernova UR6EH replacement GE Vernova Protection Relay Plug-in Module
Technical notes
UR option letters are position-sensitive; verify the full relay order code and slot map before inserting UR6EH
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which protection relay plug-in module defines the exact UR6EH configuration?
Use the complete model and the defining configuration: a plug-in module configuration for GE Multilin Universal Relay hardware identified by the full suffix UR6EH. Include every suffix and secondary assembly number shown on the nameplate.
Which installed-system evidence is decisive for matching UR6EH as a protection relay plug-in module?
Confirm relay model, slot assignment, order-code option, firmware generation, terminal mapping and chassis hardware revision. The match must be made to the installed GE Multilin Universal Relay records, not only to appearance.
Where does UR6EH perform its documented protection relay plug-in module duty?
The documented application is maintenance of protection, control and monitoring relays used on electrical power systems. In service, it provides the module function encoded by the UR order code within a compatible Universal Relay chassis.
How should a buyer establish the present supply route for UR6EH?
The OEM lifecycle is recorded as Active / Available from OEM. Apter Power confirms actual condition, available quantity, lead time and destination before issuing a dated offer.
What field condition can prevent a like-for-like UR6EH replacement?
UR option letters are position-sensitive; verify the full relay order code and slot map before inserting UR6EH Compare the proposed unit with other UR6xx option modules only through official service documentation.