Open now · we reply within 2 working hours

Talk to our team

+86 15359408275

Call and you reach an account manager, not a queue.


What happens next?

  1. Email confirmationYou will get an email confirming that we have received your enquiry.
  2. Dedicated Account ManagerOne of our team will be in touch to confirm your part(s) specification and condition.
  3. Your quoteYou will receive a comprehensive quote tailored to your specific needs.

Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 51401477-100 MP-DNCF02-201 51402455-100

All in stock · Add one and it is quoted together with the model, one shipping cost.

51401477-100 MP-DNCF02-201 51402455-100

Honeywell 51401477-100 MP-DNCF02-201 51402455-100 is a legacy TPN two-node card-file assembly identified as a 2 NODE CFA.

In Stock Ships by Tuesday, November 24 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 51401477-100 MP-DNCF02-201 51402455-100

51401477-100 MP-DNCF02-201 51402455-100Honeywell TPN Two-Node Card File Assembly
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Honeywell
Part Number
51401477-100 MP-DNCF02-201 51402455-100
Product Family
Honeywell DCS
Product Type
TPN Two-Node Card File Assembly
Stock
1
Weight
1.94 kg
Estimated shipping dimensions
43.1x17.2x6cm
Tariff Code
Please confirm the destination before shipping
Country of origin
USA
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Three linked markings: Combines board, node-designation and Honeywell part identities.
  • Upper/lower structure: Organizes the documented two-node card-file arrangement.
  • Legacy platform: Belongs to the phased-out TPN coaxial-node family.
Configuration decision: Capture card population and external cable positions before isolation.

Grounding decision: Preserve chassis and logic-ground links according to the cabinet drawing.

Outage decision: Plan restoration tests for both node sections and their shared paths.

Apter Power supports Honeywell 51401477-100 MP-DNCF02-201 51402455-100 document review, quotations and TPN card-file planning.
Honeywell 51401477-100 MP-DNCF02-201 51402455-100 TPN Two-Node Card File Assembly Manuals,Datasheets,Link
Important Notice: Manuals, software, cables, calibration data and accessories are included only when listed in the quotation.
  • Upper section: Preserve the upper node designation and populated card positions.
  • Lower section: Preserve the lower node designation and populated card positions.
  • Connector labels: Photograph every connector before cables are removed.
  • Mechanical support: Inspect guides, fasteners and contact alignment during the outage.
  • Chassis ground: Maintain the documented chassis-ground path.
  • Logic ground: Restore the logic-ground arrangement exactly as engineered.
  • Shared supply: Check common power when both node sections show symptoms.
  • Isolation control: Follow the site procedure before disturbing ground links.
  • Card placement: Return each board to its documented position.
  • Cable restoration: Verify upper/lower cable labels and connector retention.
  • Node startup: Observe both node sections through controlled energization.
  • Communication test: Confirm stable operation using the approved site procedure.
  • TPN node card file: Supports the documented legacy two-node assembly.
  • Controlled refurbishment: Allows card, cable and grounding restoration during an outage.
  • Legacy maintenance: Preserves installed TPN hardware while transition plans proceed.

Description

The assembly marking 51401477-100 MP-DNCF02-201 51402455-100 combines the card-file board number with the MP-DNCF02-201 upper/lower node designation and Honeywell part 51402455-100. Official HINTS records identify 51402455-100 as a 2 NODE CFA.

Upper and lower sections of 51401477-100 MP-DNCF02-201 51402455-100 provide the organized card and ground connections used by the installed TPN node arrangement. Connector labels, grounding links and the populated board set should be documented before the assembly is moved.

Honeywell has phased out TPN coaxial-node hardware including the family represented by 51401477-100 MP-DNCF02-201 51402455-100. Outage planning should therefore preserve node configuration, card positions, cabling and grounding rather than treating a similar card file as automatically interchangeable.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

What does Honeywell identify 51401477-100 MP-DNCF02-201 51402455-100 as?

Honeywell lists 51402455-100 as a DNCF “2 NODE CFA.” The additional 51401477-100 and MP-DNCF02-201 markings identify the backplane and assembly context visible on this complete two-node card-file asset.

Why should a buyer keep all three codes for 51401477-100 MP-DNCF02-201 51402455-100 in one inquiry?

The codes describe different levels of the same supplied asset rather than three interchangeable spare parts. Keeping the full string helps the supplier quote the complete two-node card file instead of only a backplane or partial subassembly.

How should an outage planner distinguish the two sections of 51401477-100 MP-DNCF02-201 51402455-100?

The installed card map should separate the upper and lower node sections shown on the assembly. This preserves each card and cable position without treating the two node areas as one undifferentiated rack.

Does 51401477-100 MP-DNCF02-201 51402455-100 define which plug-in cards are included?

The card-file identity alone does not define its installed board population. Honeywell lists K2LCN cards, power cords and other DNCF items separately, so the cabinet bill of materials must establish what is fitted.

What lifecycle point matters when sourcing 51401477-100 MP-DNCF02-201 51402455-100?

Honeywell placed 51402455-100 in the coaxial TPN phase-out program and identified December 31, 2025 as the end-of-sale milestone. Current sourcing should therefore be treated as legacy support, not assumed OEM production availability.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

8C-TDODB1 51307151-175
Honeywell Digital Output Module
CC-PAIH01 51405038-175
Honeywell CC-PAIH01 is a 16-channel Series C high-level analog input module that accepts current and selected voltage signals and supports HART communication.
In stock
CC-INWE01
The Honeywell CC-INWE01 is a high-performance network module. It supports multiple communication protocols, including TCP/IP and UDP/IP, enabling fast and reliable network connections.
CC-INWM01
The Honeywell CC-INWM01 is a high-performance network module. This module supports multiple communication protocols and enables fast and reliable network connections.
51305072-600
The 51305072-600 is a Honeywell LCN I/O Board (Dual Node) for TDC 3000/Experion PKS systems, replacing KLCN-CB with an addressable jump pack for LCN node integration .
51401052-100
Honeywell 51401052-100 is a History Module Smart Peripheral Controller board that manages the SCSI path to supported WREN disk drives.
In stock
51401381-100
Honeywell 51401381-100 is a five-slot cardfile backplane for compatible legacy LCN/TPS node assemblies.
In stock
51401364-100 51401363-100
Honeywell 51401364-100 51401363-100 is a legacy circuit-board assembly identified by the exact paired assembly and board markings.
In stock
8C-TCNT01 8U-TCNT01 51307032-175
Honeywell 8C-TCNT01 8U-TCNT01 51307032-175 is an earlier Series 8 C300 controller IOTA identified by the exact order codes and assembly number.
In stock
MU-TSIM12 51303932-401
Honeywell MU-TSIM12 51303932-401 is the non-CE HPM Serial Interface FTA for one Modbus RTU channel using EIA-232 or EIA-422/485 communication.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat