Features:
- 16 channels (12 single-ended, 4 differential) of 4-20 mA or voltage input with 16-bit resolution, 0.075% accuracy, and 50 ms scan rate.
- HART communication with multiple modems for fast collection of control variables from smart multivariable instruments.
- Open-wire detection with Bad PV Detection, non-incendive field power for Class 1 Div 2, and optional redundancy.
The CC-PAIH02 51405038-376 packs 16 analog input channels into a single Series C module. The 16-bit A/D converter provides 0.075% accuracy at room temperature, with 0.15% accuracy over the full 0-60°C operating range. The 50 ms scan rate means all 16 channels are updated every 50 milliseconds—sufficient for most process control loops. Inputs can be configured for 4-20 mA current (with built-in 250Ω load resistor) or voltage (0-5V, 1-5V, or 0.4-2V).
The CC-PAIH02 51405038-376 includes multiple HART modems, enabling simultaneous communication with several HART-enabled transmitters. Unlike external HART multiplexers that scan devices sequentially, this module's parallel architecture reduces overall scan time. You can access device status, perform diagnostics, read multivariable data (pressure, temperature, flow from a single transmitter), and even re-range the device—all without additional wiring. For predictive maintenance programs, HART data provides early warning of transmitter drift, sensor degradation, or electrical issues before they affect process control.
The CC-PAIH02 51405038-376 supplies non-incendive field power with individually protected current limiting circuits for Class 1, Division 2 hazardous locations. No external fusing is required, simplifying installation and reducing panel space. The module supports multiple IOTA options: 6" (CC-TAIX01, CC-GAIX21) or 9" (CC-TAID01) for non-redundant applications; 12" (CC-TAIX11, CC-GAIX11, CC-TAID11) for redundant configurations. In redundant mode, if the primary module fails, the backup automatically takes over without process interruption.
The CC-PAIH02 51405038-376 HONEYWELL Analog Input Module may still be available for purchase and support from Apter Power beyond
End-Of-Life (EOL) by the manufacturer (OEM).
HONEYWELL CC-PAIH02 51405038-376 Analog Input Module Manuals,
Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
HONEYWELL CC-PAIH02 51405038-376 Analog Input Module Specs
General
- Manufacturer HONEYWELL
- Model CC-PAIH02 51405038-376
- Condition New Original ready stock
- Product Family
CC-PAIH02 51405038-375,CC-PAIH01 51405040-175,CC-PAIH01 51405040-176
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
- High-precision process monitoring: Connects to pressure, flow, level, and temperature transmitters, providing accurate 4-20 mA analog signal acquisition.
- Intelligent instrument management: Utilizes the HART protocol to extract secondary variables (such as sensor temperature) and instrument status from field equipment.
- Harsh industrial environments: Widely deployed in petrochemical refineries, fertilizer production plants, and pulp and paper mills containing corrosive gases such as hydrogen sulfide, due to its G3 coating.
- Open Circuit/Short Circuit Detection: Automatically identifies physical connection faults in 4-20 mA circuits.
- Over-Range Monitoring: Detects signals below 3.6mA or above 21mA and sends a status bit to the C300 controller.
- HART Device Diagnostics: Monitors the "Device Status" byte of field instruments. If an instrument experiences an internal fault (such as sensor failure), the module immediately notifies the system via the HART protocol.
- Direct Replacement: Version -376 is usually fully compatible with and can replace older versions -175 or -375 without requiring changes to field wiring.
- Firmware Compatibility: After inserting a new module, it is recommended to check the firmware version using Control Builder. If the module firmware does not meet the controller requirements, the system will prompt you to download and update the firmware online.
- Redundant Upgrade: In a redundant configuration, modules should be replaced one by one. Replace the backup module first, and after it completes synchronization (Status is OK), manually switch the primary/backup relationship before replacing the other module.