Features:
- Isolated RTD signal acquisition structure supporting stable temperature input processing
- Multi-channel design enabling 6 RTD input points within a single module
- Defined electrical and terminal configuration for structured field wiring integration
The Honeywell TC-IXR061 96978379 A01 is designed as an RTD input module within the Experion PKS (C300) distributed control system architecture. It is responsible for receiving resistance signals from field temperature sensors and converting them into digital data for system processing. The TC-IXR061 96978379 A01 provides a structured interface between field instrumentation and control system data acquisition layers. This allows temperature signals to be consistently integrated into the automation system.
In system operation, the TC-IXR061 96978379 A01 supports multiple RTD input channels, enabling simultaneous temperature monitoring from several field points. It operates under defined electrical conditions with dual current consumption values and a fixed supply voltage. The TC-IXR061 96978379 A01 is designed with a controlled power dissipation limit to ensure stable performance within system constraints. Its isolated input structure supports clear signal separation during data acquisition.
The TC-IXR061 96978379 A01 also features a standardized terminal connection system using a 20-position terminal block for field wiring. This ensures organized signal termination from RTD sensors into the control system interface. The TC-IXR061 96978379 A01 is specifically structured for integration within distributed control environments where reliable temperature data conversion is required. Its role supports consistent data flow between field measurement devices and the Experion PKS platform.
The TC-IXR061 96978379 A01 Honeywell RTD Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell TC-IXR061 96978379 A01 RTD Input Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell TC-IXR061 96978379 A01 RTD Input Module Specs
General
- Manufacturer Honeywell
- Model TC-IXR061 96978379 A01
- Condition New Original ready stock
- Product Family TC-OAV081 97062772 A01
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Precision Temperature Control: In petroleum and chemical production, real-time monitoring of the internal temperature of reactors or distillation columns ensures the process remains within a safe range.
- Bearing Monitoring: Installed in the bearing housings of large rotating machinery (such as compressors and pumps), RTD probes monitor bearing temperature rise, preventing mechanical damage caused by overheating.
- Power Plant Boilers: Used to monitor multi-point temperatures in steam pipelines or feedwater systems, providing high-precision thermal feedback data for the Experion system.
- Centralized Management: In large utility facilities, in conjunction with the C300 controller, centralized monitoring and alarm management of distributed temperature points throughout the plant are provided.
- Open Wire Detection: The module features open wire detection, automatically identifying and reporting faults such as sensor line disconnections within 5 seconds.
- Range Monitoring: Real-time checks whether input signals exceed preset physical ranges; a fault status bit is sent to the system upon abnormal reading.
- Status Self-Check: Automatically performs hardware loop diagnostics during system startup and operation, supporting Block Transfer Read (BTR) commands to obtain detailed module health status.
- Interference Verification: Built-in RFI (Radio Frequency Interference) suppression capability ensures data authenticity even under strong magnetic field interference of 10 V/m through internal algorithms.
- Sensor Selection: Supports configuration of different RTD types via Control Builder software, including Platinum (100/200/500/1000 Ω), Nickel (120 Ω), and Copper (10 Ω).
- Engineering Unit Mapping: Raw resistance signals can be directly mapped to Celsius (°C), Fahrenheit (°F), or ohms (Ω), and 4-bit BCD or 16-bit binary formats can be defined.
- Channel Dedicated Setting: When using 10 Ω copper resistors (Copper RTDs), the module can be configured in dedicated mode via BTW (Block Transfer Write) to ensure linearity.
- Update Frequency Synchronization: Users can adjust the module's sampling strategy according to process requirements; the default update rate for all channels is 50 milliseconds.