Features:
- Redundant ControlNet Media
- Coated Construction
- Series A Integration
The Honeywell TK-CCR014 provides a redundant-media ControlNet interface for Series A chassis installations. The dual-media configuration supports network designs intended to preserve communication when one media path becomes unavailable.
The Honeywell TK-CCR014 is the coated version of the redundant-media interface. Its TK designation distinguishes it from corresponding TC-series variants listed without coated construction.
The Honeywell TK-CCR014 belongs to the legacy Series A ControlNet interface group used with chassis-based I/O. Honeywell migration guidance identifies these CNI cards in C200/C200E modernization projects.
The TK-CCR014 HONEYWELL ControlNet Interface Redundant Media Coated Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
HONEYWELL TK-CCR014 ControlNet Interface Redundant Media Coated Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
HONEYWELL TK-CCR014 ControlNet Interface Redundant Media Coated Module
General
- Manufacturer HONEYWELL
- Model TK-CCR014
- Condition New Original ready stock
- Product Family TK-CCR012, TK-CCR013
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Oil and Gas Operations - The Honeywell TK-CCR014 may support installed Series A ControlNet chassis in oil and gas processing, pipeline or terminal control systems requiring redundant network media.
- Power Generation - The Honeywell TK-CCR014 may be used to maintain legacy ControlNet communication between compatible Series A chassis components in existing power-generation control installations.
- Chemical Processing - The coated Honeywell TK-CCR014 may support existing redundant-media ControlNet installations in chemical plants, subject to the site’s approved cabinet, environmental and hazardous-area requirements.
- Water Treatment - The Honeywell TK-CCR014 may support legacy chassis-based monitoring and control infrastructure in water and wastewater facilities where Series A ControlNet equipment remains installed.
- Chassis Compatibility - TK-CCR014 should be installed only in a Series A chassis configuration documented as compatible with the existing Honeywell controller and I/O architecture.
- Media Configuration - Its redundant-media design must be matched with the installed ControlNet cabling arrangement; a single-media interface should not be treated as an identical replacement.
- Coating Requirement - Replacement selection should preserve the coated TK designation when the approved system configuration specifies coated hardware.
- Revision Matching - Hardware revision, firmware dependency and controller-release compatibility should be checked against the site documentation before replacing an installed TK-CCR014.
- Assess Lifecycle Risk - Review TK-CCR014 availability, installed quantities and spare-part consumption when preparing the site’s lifecycle-management plan.
- Preserve Configuration Data - Record the existing chassis layout, network topology, module revision and cable connections before beginning replacement or migration work.
- Review FTE Migration - For C200 or C200E systems using Series A chassis I/O, evaluate Honeywell’s documented migration approach using an FTE Bridge and newer controller architecture.
- Plan Phased Modernization - Where continued operation is necessary, maintain verified TK-CCR014 spares while scheduling a controlled transition that preserves existing I/O and field wiring where applicable.