Features:
- Converts absolute-encoder position into programmed transistor output switching points.
- Provides sixteen optically isolated 24 V open-emitter outputs for machine sequencing.
- Stores cam assignments in battery-buffered memory and supports dead-time compensation on eight outputs.
KUHNKE KUAX671 671.022.16 compares each absolute-angle encoder position with stored cam definitions.
The matching cam state drives one or more isolated transistor outputs, linking shaft position directly to machine control signals.
The complete order execution identifies the sixteen-output controller and must remain separate from the 14- and 30-output order numbers.
The KUHNKE KUAX671 671.022.16 Electronic Cam Controller is listed as Discontinued / Obsolete by OEM; Apter Power can assist with exact-model documentation and matching.
KUHNKE KUAX671 671.022.16 Electronic Cam Controller Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Absolute shaft-position path
- Encoder type: The controller accepts a modified Gray-code absolute-angle encoder.
- Encoder supply: The input system provides a 24 V encoder supply.
- Position transfer: Each Gray-code state represents the current shaft position.
- Processing time: The standard type processes each pulse in approximately 240 microseconds.
Stored switching definitions
- Cam allocation: Cam points can be assigned across the available outputs and programs.
- Capacity: The documented allocation limit is 128,000 cam assignments.
- Position comparison: Stored cam points are compared with the encoder state.
- Memory retention: The lithium battery preserves stored data for approximately ten years.
Sixteen isolated switching channels
- Channel count: Order execution 671.022.16 provides sixteen outputs.
- Stage type: Each channel uses an optically isolated open-emitter stage.
- Load path: The positive 24 V path is switched to the connected load.
- Fault response: A short circuit disables all outputs until the supply is reset.
Power and enclosure limits
- Supply tolerance: The 24 V DC source may vary by +20% / -20%.
- Ambient: The controller operates from 0 to 55 °C.
- Front panel: Correct panel installation provides IP65 protection at the front.
- Controller body: The controller enclosure itself is documented as IP20.