Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>

RCS-C-SM-I-100-1-P

/ 4.9
1001 reviews | Need a Specific Revision?
IAI RCS-C-SM-I-100-1-P is a 100 VAC, 100 W single-axis Robo Cylinder controller with incremental encoder feedback and PNP field I/O.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for RCS-C-SM-I-100-1-P
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for RCS-C-SM-I-100-1-P

  • Manufacturer:
    IAI
  • Part Number:
    RCS-C-SM-I-100-1-P
  • Product Family:
    IAI
  • Product Type:
    Single-axis Robo Cylinder controller
  • Stock:
    1
  • Axes:
    One
  • Feedback:
    Incremental encoder
  • Motor capacity:
    100 W
  • Input supply:
    90 to 125 VAC
  • Field I/O:
    24 VDC isolated PNP sourcing interface
  • Stored positions:
    16
  • Program memory:
    8 KB EEPROM
  • Working memory:
    128 KB SRAM
  • Operating temperature:
    0 to 40 °C
  • Operating humidity:
    85% RH maximum
  • Protection:
    IP10
  • Dielectric strength:
    1,500 VAC for one minute
  • Documented 100 W power demand:
    265 VA rated; 902 VA peak
  • Dimensions:
    8 × 19.4 × 14.3 cm
  • Weight:
    1.32 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Code Verification Data Migration Motion Proof Application
  • Single-axis RCS controller for an SM-type actuator
  • Incremental encoder feedback with 100 W motor capacity
  • 100 VAC execution with PNP sourcing I/O

RCS-C-SM-I-100-1-P is a standard IAI controller for one compatible SM-type Robo Cylinder axis.

The controller stores sixteen positions and drives the matched 100 W incremental actuator through dedicated motor and encoder connections while exchanging PNP discrete commands with the machine.

Replacement work must preserve the actuator identity, motor and encoder cables, PNP commons, position data, operating parameters, emergency-stop circuit and controller version.

Availability, condition, price, and shipping time for RCS-C-SM-I-100-1-P are confirmed during quotation.

IAI RCS-C-SM-I-100-1-P Product Family and Support Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Confirm SM actuator family
  • Retain incremental encoder feedback
  • Retain 100 W, 100 VAC and PNP executions
  • Export the position table
  • Record controller parameters and I/O assignments
  • Preserve alarm history and cable identification
  • Check direction, home and soft limits
  • Test each position command
  • Verify PNP signals and safe stopping
  • Robo Cylinder positioning
  • Assembly and transfer axes
  • Legacy 100 W IAI actuator systems
Description
RCS-C-SM-I-100-1-P controls one compatible RCS servo actuator using stored positions and a 24 VDC discrete field interface.

The configuration denotes the SM actuator family, incremental encoder feedback, 100 W capacity, 100 VAC input and PNP sourcing I/O.

Replacement requires the original actuator and encoder execution, motor and encoder cables, saved position table, I/O logic and supply-voltage class to agree with the installed system.
Alternative Names
RCS-C-SM-I-100-1-P RCSC-SM-I-100-1-P RCS C SM I 100 1 P RCS-C-SM-I-100-1-P Controller IAI RCS-C 100 W PNP Controller
Technical notes
IAI RCS-C-SM-I-100-1-P is a single-axis 100 W controller for 100 VAC service with incremental encoder feedback, stored positioning, isolated 24 VDC PNP I/O and matched motor-encoder cabling.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What feedback type does IAI RCS-C-SM-I-100-1-P require?
IAI RCS-C-SM-I-100-1-P is the incremental-encoder execution; match the actuator encoder and cable set rather than substituting an absolute-feedback controller.
Can IAI RCS-C-SM-I-100-1-P be wired into an NPN control panel?
For IAI RCS-C-SM-I-100-1-P, the P suffix identifies PNP sourcing I/O; an NPN panel requires interface changes or the matching controller execution rather than a direct substitution.
Will IAI RCS-C-SM-I-100-1-P retain the old position table?
Do not assume retention. Export the position table and parameters from the installed controller and load the approved data into IAI RCS-C-SM-I-100-1-P.
Can IAI RCS-C-SM-I-100-1-P run a different IAI actuator with the same wattage?
Motor capacity alone is insufficient; actuator type, stroke, encoder, cable and controller parameter file must all match IAI RCS-C-SM-I-100-1-P.
Why does IAI RCS-C-SM-I-100-1-P show an encoder or overcurrent alarm after exchange?
Check actuator identity, feedback execution, motor and encoder connectors, mechanical binding and restored parameters before condemning IAI RCS-C-SM-I-100-1-P.
What supply check is required for IAI RCS-C-SM-I-100-1-P?
The -1 voltage code corresponds to the 100 VAC class, so verify the cabinet supply and grounding before energizing IAI RCS-C-SM-I-100-1-P.
How should motion be validated on IAI RCS-C-SM-I-100-1-P?
With the mechanism safe, confirm direction, home, soft limits, all 16 position commands, PNP I/O behavior and stop performance for IAI RCS-C-SM-I-100-1-P.