FL SWITCH SF 14TX/2FX 2832593

/ 4.9
1001 reviews | Need a Specific Revision?
Phoenix Contact FL SWITCH SF 14TX/2FX 2832593 is an unmanaged DIN-rail Ethernet switch with copper access ports, multimode SC uplinks and redundant 24 VDC power inputs.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for FL SWITCH SF 14TX/2FX 2832593
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FL SWITCH SF 14TX/2FX 2832593

  • Manufacturer:
    Phoenix Contact
  • Part Number:
    FL SWITCH SF 14TX/2FX 2832593
  • Product Family:
    Phoenix Contact
  • Product Type:
    Industrial Ethernet Switch
  • Stock:
    1
  • Copper Interfaces:
    14 x RJ45, 10/100 Mbps, autonegotiation and autocrossing
  • Copper Segment Length:
    Up to 100 m per segment
  • Fiber Interfaces:
    2 x SC multimode, 100 Mbps full duplex
  • Fiber Wavelength:
    1300 nm
  • Switching Method:
    Unmanaged, store and forward, IEEE 802.3
  • Supply:
    Redundant 24 VDC; 18.5–30.2 VDC operating range
  • Typical Current Consumption:
    246 mA at 24 VDC
  • Alarm Interface:
    Potential-free contact via COMBICON screw connection
  • Degree of Protection:
    IP20
  • Operating Temperature:
    0 to 55 °C
  • Mounting:
    DIN rail
  • GTIN:
    4017918952259
  • Weight:
    0.5856 kg
  • Estimated shipping dimensions:
    20.5x11.53x3cm
  • Tariff Code:
    85176200
  • Country of origin:
    Taiwan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Network Plan Power & Alarm Commissioning Applications

Features:

  • Hybrid media: combines copper access connections and multimode-fiber uplinks in one unmanaged switch.
  • Redundant supply: two 24 VDC inputs support a cabinet design with independent power feeds.
  • Local diagnostics: supply, link, activity and speed LEDs support front-panel fault isolation.
The aluminum block housing places copper access, fiber backbone and alarm wiring on one DIN-rail device.

Store-and-forward switching, autonegotiation and autocrossing reduce commissioning effort while preserving a simple unmanaged network boundary.

Replacement work should preserve the installed fiber type, SC polarity, copper port map, redundant feeds and relay-alarm assignment before traffic is restored.

Apter Power supports Phoenix Contact FL SWITCH SF 14TX/2FX 2832593 Industrial Ethernet Switch quotations, documentation and network-matching review.
Phoenix Contact FL SWITCH SF 14TX/2FX 2832593 Industrial Ethernet Switch Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Copper edge: map each local machine connection to a recorded RJ45 port before removal.
  • Fiber backbone: preserve multimode cable type, SC polarity and the approved optical route.
  • Topology boundary: keep VLAN, ring and other managed functions in upstream equipment because this device is unmanaged.
  • Service record: retain port use, endpoint identity and link observations with the cabinet documentation.
  • Dual-feed plan: route independent cabinet feeds where the installed design requires redundancy.
  • Relay use: assign the potential-free contact to the documented remote alarm input.
  • Fault isolation: compare both supply indicators before treating continued traffic as proof of healthy redundancy.
  • Restart proof: remove and restore each approved feed only under the site test procedure.
  • Copper negotiation: confirm endpoint link, traffic and expected speed after reconnection.
  • Fiber path: inspect SC cleanliness, transmit-receive polarity and multimode compatibility.
  • Local indicators: use supply, link, activity and speed LEDs to separate power, media and traffic faults.
  • End-to-end test: prove required controller and supervisory communications rather than relying on carrier indication alone.
  • Mixed-media distribution: joins copper machine endpoints to a multimode-fiber plant backbone.
  • Control-cell aggregation: concentrates local Ethernet devices at a DIN-rail cabinet location.
  • Optical separation: supports fiber routes where electrical isolation or distance makes copper unsuitable.
  • Legacy network service: preserves unmanaged store-and-forward switching where no managed feature set is required.
Description
FL SWITCH SF 14TX/2FX 2832593 brings copper machine connections and multimode-fiber uplinks into one unmanaged DIN-rail switch. Its store-and-forward architecture suits control networks that need fixed media conversion without a managed-switch configuration layer.

FL SWITCH SF 14TX/2FX 2832593 uses autonegotiation and autocrossing on the twisted-pair interfaces, while the SC fiber channels operate at fixed Fast Ethernet full duplex. This division is useful when local equipment remains copper-based but the cabinet backbone requires optical isolation or extended distance.

FL SWITCH SF 14TX/2FX 2832593 replacement planning should preserve the port map, fiber type and polarity, redundant power feeds, and alarm-contact wiring. Commissioning is complete only after both media paths, supply indicators and the intended fault signal have been checked under the installed topology.
Alternative Names
FL SWITCH SF 14TX/2FX FL-SWITCH-SF-14TX/2FX Phoenix Contact 2832593 2832593 FL SWITCH SF 14TX/2FX FL SWITCH SF 14TX 2FX 2832593
Technical notes
For FL SWITCH SF 14TX/2FX 2832593, wire both redundant supply inputs and the potential-free signaling contact from the Phoenix Contact terminal diagram. A lit link LED confirms carrier presence only; it does not prove correct multimode fiber, SC polarity, copper negotiation, or end-to-end traffic. Record the original port allocation before exchange and test each required path after restart.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should a mixed copper-and-fiber cabinet be assessed before replacing FL SWITCH SF 14TX/2FX 2832593?
Compare the installed copper port map, SC multimode fiber, connector polarity, power terminals and alarm wiring with the replacement plan before disconnecting the original switch.
Why might network traffic continue after one power feed to FL SWITCH SF 14TX/2FX 2832593 is lost?
The switch accepts redundant supply inputs. Check both supply LEDs and the remote signaling circuit because continued forwarding does not prove that both feeds remain healthy.
What should be reviewed when an RJ45 device will not link through FL SWITCH SF 14TX/2FX 2832593?
Confirm the cable pair, port assignment, remote-device speed and duplex behavior, then use the link, activity and speed indicators to separate wiring from negotiation faults.
How should a failed optical link be diagnosed after installing FL SWITCH SF 14TX/2FX 2832593?
Verify that both ends use compatible multimode optics, clean the SC interfaces, confirm transmit-to-receive polarity and compare the route loss with the documented fiber design.
When should FL SWITCH SF 14TX/2FX 2832593 be kept out of a cabinet location?
Do not place it where condensation, conductive contamination or temperatures outside the documented operating envelope can occur; the enclosure is an IP20 industrial device.
What acceptance checks are appropriate before returning FL SWITCH SF 14TX/2FX 2832593 to production?
Confirm both supply indications, alarm-contact behavior, every required copper and fiber link, end-to-end traffic, and the saved port record before releasing the network.