Features:
- Single 10/100 Ethernet application and diagnostic port
- Up to 20 Modbus TCP/IP client connections
- Add-On Profile and Add-On Instruction integration
MVI69E-MBTCP occupies one 1769 slot and adds enhanced Modbus TCP/IP communications directly to a compatible CompactLogix system.
The module maintains a 10,000-word data area and supports both client-originated commands and server access through its Ethernet application port.
Before loading the controller project, check 1769 bus compatibility, power-distance rating, AOP or AOI requirements, connection counts, and the intended register map.
The ProSoft MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module is listed as Active / Available from OEM. Apter Power assists with controller matching and official documentation.
ProSoft MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft MVI69E-MBTCP Modbus TCP/IP Enhanced Communication Module Specs
General
- ManufacturerProSoft Technology
- ModelMVI69E-MBTCP
- ConditionNew Original ready stock
- Product FamilyCompactLogix Communication Module
Concurrent Modbus services
- Client sessions: MVI69E-MBTCP can maintain up to 20 Modbus TCP/IP client connections.
- Server sessions: The server supports 10 MBAP and 10 encapsulated connections.
- Function support: Documented Modbus functions include read, write, mask-write, and combined read/write services.
- Data area: A 10,000-word module database supports mapped exchanges between the network and controller.
1769 platform integration
- Slot format: The module uses one standard 1769 I/O slot.
- Backplane load: Maximum current demand is 500 mA at 5 VDC.
- Project tools: An Add-On Profile and Add-On Instruction organize configuration, status, and transfer data.
- I/O mapping: Selectable transfer sizes include 60, 120, or 240 16-bit words.
Commissioning visibility
- Ethernet access: The 10/100 RJ45 port carries application traffic and provides diagnostic access.
- Status reporting: Command errors and connection status are exposed for troubleshooting.
- Configuration workflow: Use the documented ProSoft configuration tools and controller project objects together.
- Fault isolation: Check IP addressing, command enable conditions, function codes, and destination register ranges when communication stops.