How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>

TM201-A02-B00-C00-000-E00-G00

/ 4.9
1001 reviews | Need a Specific Revision?
The ProvibTech TM201-A02-B00-C00-000-E00-G00 is a single-channel, 24VDC powered shaft vibration transmitter designed to convert eddy current proximity probe signals into a standard 4-20 mA industrial output.
Get a quick price for TM201-A02-B00-C00-000-E00-G00
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for TM201-A02-B00-C00-000-E00-G00

  • Manufacturer:
    ProvibTech
  • Part Number:
    TM201-A02-B00-C00-000-E00-G00
  • Product Family:
    ProvibTech
  • Product Type:
    Shaft Vibration Transmitter
  • Full Scale Range (A02):
    0 - 200 µm (Peak-to-Peak)
  • Output Signal:
    4-20 mA Active (Loop-powered for receiving device)
  • Load Capacity (4-20mA):
    750 Ω (Maximum)
  • Power Supply:
    22 - 30 VDC @100mA (External Power Required)
  • Frequency Response:
    Standard: 2.0 - 5.0 kHz / Optional Low Freq: 0.5 - 100 Hz
  • Linearity Error:
    < 1% FS (Full Scale)
  • Operating Temperature:
    -40°C to +85°C
  • Storage Temperature:
    -40°C to +100°C
  • Weight:
    0.52 kg
  • Estimated shipping dimensions:
    7.1x9.2x12.2cm
  • Tariff Code:
    9031809090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Communication & Connectivity Firmware & Updates Applications

Features:

  • Integrated Protection with Dual Alarm Relays
  • Preserved Signal Integrity via Buffered Output
  • Reliable Performance in Extreme Conditions
The ProvibTech TM201-A02-B00-C00-000-E00-G00 eliminates the need for a separate rack-based monitor. It combines 24VDC power regulation, signal conditioning, and dual independent SPDT relays (Alert & Danger) into a single DIN-rail mountable module, providing direct shutdown logic to your ESD or PLC.

While providing a standard 4-20 mA signal for trending and control, this device simultaneously provides a "Buffered Output" (BNC). This output carries the raw, unfiltered dynamic vibration signal, allowing predictive maintenance teams to perform high-resolution FFT analysis without interrupting the 4-20 mA loop going to the control room.

Engineered for high availability, the ProvibTech TM201-A02-B00-C00-000-E00-G00 operates reliably across a wide temperature range of -40°C to +85°C. With a temperature coefficient of <0.1% FS/°C, it maintains measurement accuracy (<1% FS linearity) even in harsh industrial environments.

The TM201-A02-B00-C00-000-E00-G00 ProvibTech Shaft Vibration Transmitter may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ProvibTech TM201-A02-B00-C00-000-E00-G00 Shaft Vibration Transmitter Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProvibTech TM201-A02-B00-C00-000-E00-G00 Shaft Vibration Transmitter

General

  • Manufacturer ProvibTech
  • Model TM201-A02-B00-C00-000-E00-G00
  • Condition New Original ready stock
  • Product Family TM201-A00-B00-C00-D00-E00-G00,TM201-A00-B00-C01-D00-E00-G00,TM201-A00-B00-C01-D00-E00-F00
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • 4-20 mA Active Output (Primary): The primary communication method is an active 4-20 mA analog signal proportional to 0-200 µm pk-pk displacement. It connects directly to a PLC or DCS analog input module.
  • Buffered Output (BNC): Provides a raw AC signal (same sensitivity as the connected eddy current probe) for portable analyzers. This allows technicians to diagnose specific faults (e.g., imbalance, misalignment) that are averaged out in the 4-20 mA output.
  • Discrete Relay Outputs: Communicates "Alert" and "Danger" status directly to the emergency shutdown system (ESD) via dry contact relays, bypassing DCS scan time for faster protection.
  • Remote Reset Terminals (RST/BYP): Provides a hardwired connection from the control room to the field, allowing operators to reset latched alarms or bypass alarms during startup sequences.
  • Fixed Firmware Logic: Unlike smart transmitters or PLCs, the ProvibTech TM201 runs a fixed, deterministic algorithm designed for safety and reliability. "Updates" are not user-applicable; the device functions based on hardware-defined signal filtering and setpoints.
  • Filter Configuration (Factory Set): The frequency response is determined by the order code (E00 in this case, typically standard 2.0-5.0 kHz). No firmware flashing is required, as the hardware filtering is set at the factory based on the configuration ordered.
  • No Software Dependencies for Operation: A key operational advantage is that it is configuration-free for basic operation. Setpoints are set via hardware push buttons, not firmware downloads, eliminating cybersecurity risks associated with field device updates.
  • Calibration Stability: The firmware/electronics ensure excellent long-term stability (temperature coefficient <0.1% FS/°C), negating the need for annual recalibration in most non-critical environments, though periodic drift checks are recommended.
  • Sleeve Bearing Machinery: Specifically designed for large rotating equipment where shaft relative vibration must be measured, such as steam turbines and gas turbines in power generation.
  • Critical Turbo-Compressors: Provides 4-20 mA output to DCS for surge control and vibration trip logic in oil & gas refineries and petrochemical plants.
  • Retrofit Projects: The ProvibTech TM201-A02-B00-C00-000-E00-G00 fits into standard DIN rails and replaces older, malfunctioning monitors without rewiring the entire junction box, supporting legacy system upgrades.
  • Water/Wastewater & HVAC: Monitoring large centrifugal pumps and industrial fans to detect impeller imbalance or bearing wear before mechanical failure occurs.
Description
The ProvibTech TM201-A02-B00-C00-000-E00-G00 integrates signal conditioning, dual alarm relays, and a loop-powered 4-20 mA output into a compact, DIN-rail mountable enclosure, effectively replacing larger, more expensive rack-based monitoring systems . Designed to interface directly with standard 8mm eddy current proximity probes (such as the TM0180 series), it measures radial shaft vibration (displacement) and converts the dynamic signal into a proportional analog output for seamless integration with PLC, DCS, and SCADA systems.

Engineered for reliability in harsh industrial environments, the ProvibTech TM201-A02-B00-C00-000-E00-G00 features independent SPDT dry contact relays for Alert and Danger notifications, suitable for direct integration into safety shutdown loops . The front panel provides immediate visual status indication via OK, Alert, and Danger LEDs, alongside push-button functionality for alarm setpoint verification and reset operations.

The robust design of the ProvibTech TM201-A02-B00-C00-000-E00-G00 guarantees stable operation across a wide temperature range of -40°C to +85°C. It provides a buffered output (Buf Out) of the raw dynamic signal for portable data collectors or analyzers, ensuring that while the control room receives the 4-20 mA trend, maintenance teams have access to the original waveform for detailed spectral analysis.
Alternative Names
TM201-A00-B00-C00-D00-E00-G00 TM201-A00-B00-C01-D00-E00-G00 TM201-A00-B00-C01-D00-E00-F00 TM201-A02-B00-C01-D00-E00-F00 TM301-A02-B00-C00-D00-E00-F00-G00 TM302-A00-B00-C01-D00-E02-F00-G00
Technical notes
The ProvibTech TM201-A02-B00-C00-000-E00-G00 requires an external 22-30 VDC power supply and is NOT loop-powered. It provides a 4-20 mA active output capable of driving loads up to 750 Ω .The A02 code in this specific model denotes a full-scale measurement range of 0-200 µm peak-to-peak (pk-pk). Please confirm this matches your application requirements before ordering .
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the primary operating scenario for the ProvibTech TM201-A02-B00-C00-000-E00-G00?
It is specifically designed for continuous, unattended monitoring of radial shaft vibration in rotating machinery with sleeve bearings. Common applications include steam turbines, gas turbines, centrifugal compressors, large pumps, and industrial fans .
Can the ProvibTech TM201-A02-B00-C00-000-E00-G00 interface with non-ProxibTech probes?
Yes. It is compatible with standard 8mm eddy current proximity probes, including the ProvibTech TM0180 series, Bentley Nevada 3300/7200 series, or equivalent 5mm and 8mm probes. The D00 code specifies the sensor interface configuration—please verify your probe sensitivity matches the transmitter's driver requirements .
How do I configure the alert and danger setpoints on the ProvibTech TM201-A02-B00-C00-000-E00-G00?
Use the three push buttons on the front panel (SET, +, -). The device allows you to set Alert and Danger thresholds as a percentage of the full scale (0-200 µm for the A02 model). The built-in time delay prevents false triggering during startup or transient events. Note that setpoints are verified on-site without needing configuration software.
Does the ProvibTech TM201-A02-B00-C00-000-E00-G00 support redundant power inputs?
While the TM201 itself requires a single 22-30 VDC input, many installations pair it with the TM900 Power Converter. The TM900 converts 95-250 VAC to 24 VDC and can power up to five TM201 modules, centralizing power management and providing a degree of power redundancy at the system level.
Is the ProvibTech TM201-A02-B00-C00-000-E00-G00 suitable for safety applications?
Yes. It features epoxy-sealed, single-pole double-throw (SPDT) relays with dedicated Alert and Danger trip circuits, making it suitable for use as a primary protection device against catastrophic machinery failure. It complies with API 670 standards for machinery protection systems.