Technical specifications for HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW

  • Manufacturer:
    Rexroth
  • Part Number:
    HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW
  • Product Family:
    Rexroth
  • Product Type:
    IndraDrive Cs Compact Converter
  • Stock:
    1
  • Protection category:
    IP20
  • Mains connection class:
    3 × AC 200–500 V, ±10%
  • Control panel / firmware:
    Standard control panel; firmware ordered separately
  • Allowed switching frequencies:
    4, 8, 12 and 16 kHz
  • Maximum output current:
    18.0 A at 4, 8 and 12 kHz; 16.5 A at 16 kHz
  • Continuous output current:
    7.6 A at 4 kHz; 6.1 A at 8 kHz; 4.1 A at 12 kHz; 2.5 A at 16 kHz
  • Dimensions:
    7.0 × 26.8 × 19.6 cm
  • Operating ambient temperature:
    0 to +40°C; derated operation up to +55°C
  • Installation altitude without derating:
    Up to 1000 m
  • Relative humidity:
    5 to 95%, non-condensing
  • Weight:
    2.096 kg
  • Tariff Code:
    8504409999
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Protocol Project Encoder and EMC Thermal and Safety Design Application
  • Match the W0018, B-ET and EC configuration by complete type code
  • Restore the approved Multi-Ethernet protocol and controller data layout
  • Retain an external machine safety design because the safety option is NN

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is a Bosch Rexroth IndraDrive Cs compact converter for one servo axis.

It combines the 200–500 V three-phase mains class with Basic control, ET Multi-Ethernet and EC multi-encoder feedback; no integrated safety option is specified.

Confirm the network project, motor and encoder, external safety chain, firmware and switching-frequency duty before operation.

Availability, condition, price, and shipping time for HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW are confirmed during quotation.

Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW IndraDrive Cs Resources and Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Identify the active ET protocol from the approved machine project
  • Restore network identity, cyclic data layout and controller timing
  • Do not infer control readiness from link status alone
  • Select an EC-supported encoder and the correct feedback cable
  • Separate feedback wiring from motor conductors and bond shields correctly
  • Verify encoder direction and commutation before applying load
  • Use continuous-current limits for the selected switching frequency
  • Maintain the specified mounting position, clearance and cabinet airflow
  • Validate the external safety chain because this configuration has no integrated safety option
  • 18 A single-axis service on 200–500 V three-phase mains
  • Basic-control axes requiring ET Multi-Ethernet and EC multi-encoder feedback
  • Installations that provide safety externally because this exact NN configuration has no integrated safety option
Description
HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is a Bosch Rexroth IndraDrive Cs compact converter for one servo axis.

This W0018 configuration uses the 200–500 V three-phase mains class, Basic control, ET Multi-Ethernet and an EC multi-encoder interface. The safety position is NN, so no integrated safety option is specified; the standard panel is included and firmware is ordered separately.

Match the machine Ethernet protocol, motor and encoder, external safety chain, switching-frequency duty, mains protection and approved parameter set before operation.
Alternative Names
HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW HCS 01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW Bosch Rexroth IndraDrive Cs HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW
Technical notes
HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW combines Basic control, ET Multi-Ethernet and EC multi-encoder feedback with no integrated safety option. Firmware, motor, feedback cable and the external safety chain must be matched separately.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should machine safety be handled with HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW?
This complete configuration has no integrated safety option at the third interface position. Retain and validate the machine's documented external safety circuit; do not assume that an L3 or L4 safety project can be transferred without hardware and risk-assessment changes.
What must be restored on HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW when the machine uses PROFINET, EtherNet/IP, EtherCAT or Sercos III?
Restore the protocol supported by the approved firmware together with network identity, controller device configuration, cyclic I/O layout and timing. ET is multiprotocol-capable, but it does not auto-convert one master project into another.
Can HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW replace the W0013 `-02` unit without changing the supply?
No. This model uses the `-03` 200–500 V three-phase mains class, whereas the W0013 example uses the `-02` low-voltage class. Supply protection, motor voltage, cabinet wiring and axis sizing must be redesigned and approved.
Does the complete HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW order code include the motor and encoder cable?
No. EC identifies the drive's multi-encoder interface, not a supplied motor or feedback cable. Match the actual motor, connector, encoder technology, cable length and shielding as separate compatibility items.
Why can HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW report encoder faults only while the motor is loaded?
Inspect shielding and bonding, feedback-cable routing near motor conductors, connector seating, encoder supply and parameter selection. Load-dependent noise or movement can expose faults that are not visible at standstill.
What causes thermal trips on HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW at 12 or 16 kHz?
Continuous current decreases as switching frequency rises. Check the actual RMS current and low-speed duty against the frequency-specific limit, then inspect ambient temperature, mounting clearance and airflow.
Does the FW suffix mean HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is delivered with ready-to-run application firmware?
No. The official type code states that firmware is ordered separately. The required firmware family and release must match the Basic control section, selected Ethernet protocol, motor and machine functions.