Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW

/ 4.9
1001 reviews | Need a Specific Revision?
Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is an IndraDrive Cs compact converter with 54.0 A at 4 kHz maximum current, Multi-Ethernet, multi-encoder feedback and certified Safe Torque Off.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW

  • Manufacturer:
    Rexroth
  • Part Number:
    HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
  • Product Family:
    Rexroth
  • Product Type:
    IndraDrive Cs Compact Converter
  • Stock:
    1
  • Product line / design:
    HCS01 / design 1
  • Maximum output current:
    54.0 A at 4 kHz
  • Continuous output current:
    21.0 A at 4 or 8 kHz; 15.5 A at 12 kHz; 16 kHz is not supported for W0054
  • Mains connection:
    3-phase 200 to 500 VAC, 50 to 60 Hz
  • Output voltage:
    3-phase 0 to 500 VAC
  • Control section:
    BASIC (B)
  • Communication:
    ET Multi-Ethernet: EtherNet/IP, EtherCAT, sercos III and PROFINET IO
  • Encoder interface:
    EC multi-encoder interface
  • Safety option:
    L3 certified Safe Torque Off (STO)
  • Control voltage:
    24 VDC ±20%
  • Protection:
    IP20
  • Operating ambient:
    0 to +40°C nominal; derated operation to +55°C
  • Firmware scope:
    FW: firmware ordered separately
  • Dimensions:
    13.0 × 22.0 × 26.8 cm
  • Weight:
    4.6 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals High-Current Cabinet Firmware & Network Loaded Commissioning Application
  • Do not configure W0054 for 16 kHz switching
  • Provide the wider cabinet space and higher-current power design
  • Commission progressively while monitoring thermal and regenerative behavior

HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is a Bosch Rexroth indradrive cs compact converter for the IndraDrive Cs HCS01 family.

Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is an IndraDrive Cs compact converter with 54.0 A at 4 kHz maximum current, Multi-Ethernet, multi-encoder feedback and certified Safe Torque Off. The complete order code specifies Basic control, ET Multi-Ethernet, EC multi-encoder input and L3 Safe Torque Off; FW means the required firmware is ordered separately.

Before installation or replacement, verify the complete nameplate, compatible companion hardware, wiring or network design, saved configuration and commissioning plan.

Availability, condition, price, and shipping time for HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW are confirmed during quotation.

Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW IndraDrive Cs Compact Converter Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Allow for 130 mm device width and conductor routing
  • Verify mains protection, choke/filter and protective earth
  • Maintain documented clearances and airflow
  • Use only 4, 8 or 12 kHz on W0054
  • Restore approved firmware and ET protocol project
  • Match EC feedback and motor-current parameters
  • Validate L3 STO and controlled-stop sequence
  • Increase load while monitoring current and temperature
  • Prove regenerative stops and diagnostic recovery
  • High-load machine-tool axes
  • Forming, converting and winding machinery
  • Heavy packaging and material-handling systems
Description
HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is a Bosch Rexroth indradrive cs compact converter for the IndraDrive Cs HCS01 family.

Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is an IndraDrive Cs compact converter with 54.0 A at 4 kHz maximum current, Multi-Ethernet, multi-encoder feedback and certified Safe Torque Off. The complete order code specifies Basic control, ET Multi-Ethernet, EC multi-encoder input and L3 Safe Torque Off; FW means the required firmware is ordered separately.

Before installation or replacement, confirm the complete HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW identity, compatible hardware, wiring, saved configuration and installed-system requirements.
Alternative Names
HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW HCS01.1E W0054 A 03 B ET EC NN L3 NN FW HCS011EW0054A03BETECNNL3NNFW Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
Technical notes
HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW combines the exact mains/current class with Basic control, ET Multi-Ethernet, EC feedback and L3 STO. Firmware is a separate order item and the complete machine configuration must be restored.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW use the 16 kHz setting available on smaller HCS01 units?
No. The official W0054 data supports 4, 8 and 12 kHz. Restore a supported switching frequency and recheck motor derating and acoustic expectations.
What cabinet changes should be checked before installing HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW?
Confirm the 130 mm width, conductor bending space, terminal access, clearances, airflow, heat rejection and protection hardware for the larger current class.
How should the supply for HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW be engineered?
Verify 3-phase 200–500 V mains, fuses, contactor, choke or filter, short-circuit conditions, protective earth and the actual continuous/regenerative duty.
Can a smaller HCS01 control project be copied directly to HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW?
Only after engineering review. Motor data, current limits, switching frequency, braking, thermal model, ET mapping and STO configuration must match the new axis.
What should be checked when HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW reports encoder faults under load?
Inspect EC cable shielding and routing, connector seating, supply voltage, encoder type, motor data, vibration, grounding and diagnostic history.
Why might HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW repeatedly reach thermal warning without exceeding 54 A?
The 54 A figure is a peak condition. Check continuous current, 8/12 kHz derating, cabinet temperature, airflow, cycle duty and motor cable losses.
How should HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW be commissioned on a high-load axis?
Validate electrical protection and STO first, then feedback and brake; increase load gradually while monitoring current, DC-bus, temperature, stopping and network diagnostics.