TDM4.1-020-300-W0

/ 4.9
1001 reviews | Need a Specific Revision?
TDM4.1-020-300-W0 is a naturally cooled 300 V Rexroth/INDRAMAT servo module rated 20 A peak and 15 A continuous.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for TDM4.1-020-300-W0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for TDM4.1-020-300-W0

  • Manufacturer:
    Rexroth
  • Part Number:
    TDM4.1-020-300-W0
  • Product Family:
    Rexroth
  • Product Type:
    AC Servo Drive Module
  • Stock:
    1
  • Type current:
    20 A
  • Peak current:
    20 A
  • Continuous current:
    15 A
  • DC-link voltage:
    300 V DC ±15%
  • Continuous power:
    6 kW
  • Power loss at continuous current:
    110 W
  • +24 V signal-processing load:
    400 mA
  • +15 V measuring-supply load:
    150 mA
  • -15 V measuring-supply load:
    60 mA
  • Rated ambient temperature:
    +5 to +45°C
  • Maximum ambient temperature with derating:
    +55°C
  • Storage and transport temperature:
    -30 to +85°C
  • Maximum installation elevation without derating:
    1000 m
  • Humidity class:
    F according to DIN 40040
  • Protection category:
    IP10 according to DIN 40050
  • Dimensions:
    7.0 × 39.0 × 35.5 cm
  • Weight:
    8 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals MOD17/MOD18 TDM4 Interface Natural Cooling Application
  • Retain the TDM4-specific MOD17/MOD18 programming module
  • Maintain the W0 vertical natural-convection path and applicable baffle
  • Reproduce the TDM4 controller and feedback wiring rather than copying a TDM3 layout

TDM4.1-020-300-W0 is the 20 A natural-convection member of the TDM4 servo-drive family.

It sustains 15 A and 6 kW from the 300 V DC link, with 110 W of loss at continuous duty.

The TDM4 interface, MOD17/MOD18 identity, motor feedback and cabinet baffle position must all be preserved during replacement.

Availability, condition, price, and shipping time for TDM4.1-020-300-W0 are confirmed during quotation.

Bosch Rexroth TDM4.1-020-300-W0 AC Servo Drive Module Product Series, Service, Industry Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Match the module to the exact motor and machine function
  • Preserve the original parameter and compensation identity
  • Do not substitute MOD13/MOD14 from a TDM3 axis
  • Reproduce the original controller-input assignment
  • Verify feedback, current reduction and ready-chain wiring
  • Keep shields and reference potentials in the approved arrangement
  • Maintain vertical ventilation clearances
  • Install the baffle at the documented left-edge condition
  • Do not add an LE5 fan and relabel the W0 hardware
  • TDM4 servo axes using an approved MOD17/MOD18 programming module
  • Natural-convection axes operating within 15 A continuous and 20 A peak
  • 300 V modular drive packages retaining the original TDM4 controller wiring
Description
TDM4.1-020-300-W0 is a naturally cooled Bosch Rexroth/INDRAMAT AC servo drive module designed for operation from a 300 V DC link.

The exact TDM4.1 technical-data entry specifies 6 kW continuous power, 110 W power loss at continuous current and a W0 natural-convection cooling arrangement.

This model must retain the TDM4-specific controller connections and the correct MOD17 or MOD18 programming module. Motor identity, feedback wiring and cabinet clearances must be checked before replacing a TDM3 or another drive generation.
Alternative Names
TDM4.1-020-300-W0 TDM 4.1-020-300-W0 Bosch Rexroth TDM4.1-020-300-W0 Bosch Rexroth Indramat TDM4.1-020-300-W0 Rexroth Indramat TDM4.1-020-300-W0
Technical notes
TDM4.1-020-300-W0 shares some ratings and enclosure dimensions with TDM3 products, but its controller interface and MOD17/MOD18 programming-module family are different. W0 remains a natural-convection configuration and cannot be uprated by fitting a fan.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can TDM4.1-020-300-W0 use a MOD13 module from TDM3.2?
No. TDM4 uses the documented MOD17/MOD18 programming-module family. Keep the module, motor and machine-function identity tied to the original TDM4 axis.
Is TDM4.1-020-300-W0 interchangeable with TDM3.2-020-300-W0 because both are 20 A W0 units?
No. The interface and programming-module families differ. Verify controller wiring, feedback, MOD identity and machine logic rather than comparing current and cooling codes alone.
Can a fan be fitted to TDM4.1-020-300-W0 to increase its continuous rating?
No. W0 is the documented natural-convection variant. A fan retrofit does not create the separately defined W1 electronic configuration or change its official current table.
Why can TDM4.1-020-300-W0 remain in current reduction after replacement?
Check the Ired input, controller assignment, programming module, reference potentials and saved machine logic. The symptom is often an interface or parameter issue, not a power-stage fault.
What prevents TDM4.1-020-300-W0 from cooling correctly at the left edge of a drive package?
A missing cooling baffle can allow the natural convection path to bypass the heatsink. Apply the documented baffle rule and maintain vertical clearance.
Can TDM4.1-020-300-W0 operate as a standalone mains drive?
No. It requires the DIAX 300 V DC link and control supplies from the compatible system supply module, plus the matched motor and programming module.
Why can TDM4.1-020-300-W0 show unstable speed after moving the original electronics?
Recheck zero-point adjustment, command reference, feedback polarity, shield termination and MOD17/MOD18 identity. Mechanical fit does not preserve the TDM4 control-loop setup.