Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Discontinued / Obsolete by OEM
    For 140DDI35300, Apter Power supplies quotations, manuals, and product-selection assistance.

140DDI35300

/ 4.9
1001 reviews | Need a Specific Revision?
Schneider Electric 140DDI35300 is a Modicon Quantum discrete input module with thirty-two 24 V DC positive-sink channels arranged in four groups.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 140DDI35300
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 140DDI35300

  • Manufacturer:
    Schneider Electric
  • Part Number:
    140DDI35300
  • Product Family:
    Modicon Quantum
  • Product Type:
    32-Point 24 V DC Discrete Input Module
  • Stock:
    1
  • Channel Indicators:
    32 green LEDs
  • Channel Groups:
    4
  • Input Logic:
    Positive sink
  • Module Indicators:
    Active and fault LEDs
  • Guaranteed On State:
    15 to 30 V DC
  • Guaranteed Off State:
    -3 to 5 V DC
  • Input Words:
    2
  • Input Impedance:
    2500 ohm
  • Response Time:
    1 ms maximum for either transition
  • Group-to-Bus Isolation:
    1780 Vrms for 1 minute
  • Group-to-Group Isolation:
    500 Vrms for 1 minute
  • Bus Current:
    330 mA
  • Operating Temperature:
    0 to 60 °C
  • Storage Temperature:
    -40 to 85 °C
  • Weight:
    0.661 lbs (0.3 kg)
  • Estimated shipping dimensions:
    4.65x16.45x30.97cm
  • Tariff Code:
    8537101190
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Groups Signal Levels Isolation Indicators

Features:

  • Thirty-two positive-sink inputs occupy four channel groups and two controller words.
  • Group-to-bus and group-to-group isolation separate the field circuits.
  • Individual channel lamps accompany separate Active and external-fault indicators.
140DDI35300 converts field voltage states into the Quantum input image with a one-millisecond maximum transition response.

The four-group structure keeps channel references and isolation boundaries identifiable during wiring checks.

Front indicators allow field presence, bus activity, and external fault conditions to be evaluated separately.

The Schneider Electric 140DDI35300 Modicon Quantum Discrete Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Schneider Electric 140DDI35300 Modicon Quantum Discrete Input Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Four-Group Channel Structure

  • Channels: Thirty-two inputs are distributed across four groups.
  • Logic: The field circuits use positive-sink input behavior.
  • Image size: Two input words carry all channel states to the controller.
  • Reference check: Group wiring must preserve the documented field reference.

Voltage-State Interpretation

  • Supply window: Input operation is specified from 19.2 to 30 V DC.
  • On threshold: A 15 to 30 V DC level guarantees state one.
  • Off threshold: A -3 to 5 V DC level guarantees state zero.
  • Transition: Either state change is reported within one millisecond.

Electrical Group Boundaries

  • Bus separation: Each field group withstands 1780 Vrms from the bus for one minute.
  • Between groups: Adjacent groups withstand 500 Vrms for one minute.
  • Input path: Each channel presents a 2500-ohm impedance.
  • Protection: The input circuit uses resistor-limited protection.

Front Diagnostic Separation

  • Input lamps: Thirty-two green LEDs show the individual channel states.
  • Active lamp: A green Active LED indicates bus communication.
  • Fault lamp: A red F indicator reports an external fault condition.
  • Comparison: LED state can be compared with the controller input image.
Description
Schneider Electric 140DDI35300 receives thirty-two 24 V DC field states and places them into two input words on the Modicon Quantum bus. The channels are divided into four groups so the field references remain organized at the module connection boundary.

Positive-sink input circuits on 140DDI35300 recognize an on state from 15 to 30 V DC and an off state from -3 to 5 V DC. Each channel passes through a 2500-ohm input path before its state reaches the module electronics.

Isolation in 140DDI35300 separates every channel group from the Quantum bus and from adjacent groups. This arrangement keeps process wiring faults within the documented electrical boundaries while the bus continues to exchange the two-word input image.

Thirty-two green channel lamps on 140DDI35300 display individual input states, while separate Active and fault indicators report bus communication and external fault conditions. The front indications therefore distinguish a field signal from a module-level communication problem.
Alternative Names
140 DDI 353 00 140DDI 35300 Schneider 140DDI35300 Schneider Electric 140DDI35300 140DDI35300 Input Module 140DDI35300 Quantum Input I40DDI35300 140DDI3S300
Technical notes
Schneider Electric 140DDI35300 maps four isolated groups of positive-sink inputs into two bus words and reports each channel through a front LED.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does Schneider Electric 140DDI35300 show an input LED but no controller bit?
Check Schneider Electric 140DDI35300 rack seating, Active status, bus communication, input-word mapping, controller scan, and module diagnostics.
Why do several Schneider Electric 140DDI35300 channels fail together?
Inspect Schneider Electric 140DDI35300 group reference, field supply, connector wiring, shared conductors, and isolation-group assignment.
What voltage guarantees an on state for Schneider Electric 140DDI35300?
Schneider Electric 140DDI35300 guarantees state one from 15 to 30 V DC within its documented input range.
How quickly does Schneider Electric 140DDI35300 report a changing input?
Schneider Electric 140DDI35300 specifies a maximum one-millisecond response for either off-to-on or on-to-off transition.
What should be checked when Schneider Electric 140DDI35300 fault LED is red?
Review Schneider Electric 140DDI35300 field wiring, group supplies, connector condition, input levels, bus state, and rack diagnostics.
How many controller words does Schneider Electric 140DDI35300 use?
Schneider Electric 140DDI35300 maps its thirty-two discrete channels into two input words.