Features:
- Non-stabilized line-side supply function for a SIMODRIVE 611 drive group.
- Official Siemens article designation of 10/25 kW.
- Legacy spare-part configuration with a Siemens-listed successor.
The exact order number identifies a SIMODRIVE 611-A/611-D infeed module that supplies the common DC link.
The unit forms part of a configured drive group and must be coordinated with the connected drive modules, line supply and equipment bus.
For replacement, preserve the installed electrical and mechanical baseline and verify the later article before recommissioning.
Availability is quotation-specific for this discontinued article. Send the complete nameplate and system details for verification.
Verified resources for Siemens 6SN1145-1AA00-0AA0:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Service and replacement work in installed SIMODRIVE 611-A/611-D drive groups.
- Legacy CNC and production-machine cabinets using a common 611 DC link.
- Maintenance projects that require the complete infeed-module MLFB to be matched.
- Install the infeed module at the far-left, line-side entry of the documented SIMODRIVE 611 group, ahead of the connected power modules.
- Coordinate the line connection, DC-link busbars and looped equipment-bus cable with every connected module before energizing the drive group.
- Isolate the line supply and de-energize the enable and contactor-control circuits before changing connections or installing DC-link covers.
- Evaluate the ready and fault signals together with the configured contactor-control circuit so a fault is not treated as an isolated module indication.
- Keep the protective conductor, line-side circuit protection and cabinet grounding aligned with the Siemens system design and leakage-current requirements.
- After replacement, verify DC-link charging, enable response and the complete protection chain before returning the connected drives to service.
- Compatible with SIMODRIVE 611-A and 611-D modular drive groups designed for a 10/25 kW non-stabilized line infeed.
- Not suitable as a direct substitute for regulated infeed/regenerative modules because their power-flow and DC-link-control functions differ.
- Siemens lists 6SN1145-1AA01-0AA2 as the successor, but installation and electrical conditions must be verified before substitution.