Features:
- The assembly code and Siemens order number support two different lookup paths for the same module.
- The converter quadrant arrangement determines which placement drawing applies.
- An X90 reference must be read together with its associated G/K branch.
Use C98043-A7017-L1 when reading the board marking and 6RY1703-0FA12 when matching the order record.
Choose 1Q or 4Q topology before following repeated board positions.
Use the converter electrical class only to select the applicable layout, not as a substitute for the full module identifier.
The Siemens C98043-A7017-L1 TSE Capacitor Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens C98043-A7017-L1 TSE Capacitor Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Dual-Number Relationship
- Assembly marking: C98043-A7017-L1 is the code used to identify the board itself.
- Order reference: 6RY1703-0FA12 is the associated Siemens ordering identity.
- Shared product: Both references point to the TSE capacitor-module context on this page.
- Matching rule: Keep the complete -L1 suffix when comparing a board marking with an order record.
Choosing the Correct Layout
- One-quadrant path: The 1Q drawing places the module around the G1/K1 device references.
- Four-quadrant path: The 4Q drawing extends placement to the additional G2/K2 branch.
- First decision: Determine the converter topology before following any repeated board position.
- Drawing boundary: A placement taken from one topology should not be transferred to the other.
Board-Side Connection Reference
- Interface marker: X90 identifies the board-side connection at each A7017 position.
- Repeated label: More than one X90 can appear because the module is repeated around the thyristor branches.
- Trace method: Pair each X90 position with the G/K reference shown beside it.
- Topology check: Confirm the 1Q or 4Q drawing before assigning an X90 connection to C98043-A7017-L1.
Gate and Cathode Branches
- First branch: G1 and K1 identify the primary device path shown in both converter arrangements.
- Second branch: G2 and K2 appear when the four-quadrant circuit adds the second path.
- Board distribution: A7017 positions are arranged around the applicable device groups rather than at one universal location.
- Layout choice: Converter topology and electrical class together determine which branch drawing should be used.