Features:
- A PROFIBUS DP port links one ET 200MP station to its DP master.
- The station backplane accepts as many as twelve S7-1500 I/O modules.
- A 24 V DC input feeds the interface and its available backplane-power budget.
Siemens 6ES7155-5BA00-0AB0 converts PROFIBUS telegrams into ET 200MP backplane data.
The supplied bus connector places 6ES7155-5BA00-0AB0 on the configured PROFIBUS segment.
Station diagnostics from 6ES7155-5BA00-0AB0 distinguish bus faults from backplane module faults.
The Siemens 6ES7155-5BA00-0AB0 SIMATIC ET 200MP IM 155-5 DP ST Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7155-5BA00-0AB0 SIMATIC ET 200MP IM 155-5 DP ST Interface Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
PROFIBUS Station Exchange
- Master path: The DP master sends output data and receives input and diagnostic data through the PROFIBUS port.
- Addressing: The station address in hardware and in the master project must identify the same ET 200MP node.
- Bus rate: The interface follows the configured segment rate up to the documented maximum.
- Termination: Termination is enabled only at the physical ends of the PROFIBUS segment.
ET 200MP Module Chain
- Station head: The interface module occupies the head position and starts the ET 200MP backplane.
- Module order: The physical I/O sequence must match the slots configured in the DP hardware project.
- Power budget: The fourteen-watt feed is shared by the installed backplane modules rather than reserved for one slot.
- Module limit: A single station contains no more than twelve supported S7-1500 I/O modules.
Bus and Station Fault Isolation
- DP state: Bus indicators show whether the interface has entered cyclic exchange with the master.
- Station state: Module diagnostics identify a missing, mismatched, or faulted backplane device.
- Project check: GSD data, slot order, parameters, and address assignments must correspond to the installed station.
- Firmware check: The approved firmware package and update procedure must match this complete order number.
Supply and Mechanical Assembly
- Supply input: The documented 24 V DC range feeds the interface electronics and backplane converter.
- Rail mounting: The module locks onto the ET 200MP mounting rail before the I/O chain is assembled.
- Orientation: Cabinet clearances and temperature limits depend on the selected mounting orientation.
- Protection: The IP20 assembly requires installation inside a suitable industrial enclosure.