    Apter Power supports 6ES7157-0AA82-0XA0 quotations, manual access and DP/PA Link model review.

6ES7157-0AA82-0XA0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens IM 157 order number 6ES7157-0AA82-0XA0 forms the interface portion of a DP/PA Link and transfers DP V1 communication to DP and PA networks.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7157-0AA82-0XA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7157-0AA82-0XA0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7157-0AA82-0XA0
  • Product Family:
    Siemens Simatic DP
  • Product Type:
    IM 157 DP/PA Link Interface Module
  • Stock:
    1
  • System:
    PROFIBUS DP/PA
  • Communication Conversion:
    DP V1 to DP and PA
  • Module Replacement:
    Supported during operation
  • Information Function:
    Supported
  • Firmware Update:
    Via bus
  • Process-Control Functions:
    Extended
  • Operating Temperature:
    -25 to +60 °C
  • Weight:
    0.648 lbs (0.294 kg)
  • Estimated shipping dimensions:
    15.2×13.2×5cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals PA Link Role Online Changes Firmware Route Temperature Range

Features:

  • 6ES7157-0AA82-0XA0 is the V4.x IM 157 interface module for a PA Link.
  • DP V1 communication is carried to both DP and PA portions of the link.
  • The module supports operational replacement and firmware transfer through the bus.
The IM 157 occupies the interface position; one or more separate couplers complete the DP/PA Link assembly.

An information function exposes module data required by the documented process-control feature set.

The extended-temperature hardware is rated for operation from -25 to +60 °C.

The Siemens 6ES7157-0AA82-0XA0 IM 157 DP/PA Link Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7157-0AA82-0XA0 IM 157 DP/PA Link Interface Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Interface Position

  • IM function: 6ES7157-0AA82-0XA0 provides the interface-module portion of the PA Link.
  • Coupler relationship: One or more DP/PA couplers complete the network transition with the IM 157.
  • Upper network: The link presents its communication toward the PROFIBUS DP system.
  • Lower network: Connected couplers carry communication onward to the PROFIBUS PA side.

Operation-Time Functions

  • Module replacement: The V4.x IM 157 supports replacement while the system remains in operation.
  • Information access: The module exposes its documented information function to the control system.
  • Process functions: Extended process-control functions are part of the 0AA82 feature set.
  • Version check: Project records should identify the V4.x hardware and firmware level.

Bus-Based Updating

  • Transfer path: Firmware reaches 6ES7157-0AA82-0XA0 through the communication bus.
  • Interface target: The bus update function applies to the IM 157 interface module.
  • Order-code identity: The documented target is IM 157 order number 6ES7157-0AA82-0XA0.
  • Functional level: The official module listing associates the update capability with V4.x.

Extended-Temperature Hardware

  • Lower limit: The IM 157 hardware is specified down to -25 °C during operation.
  • Upper limit: The documented operating ceiling is +60 °C.
  • Order-code scope: This range belongs to the complete 6ES7157-0AA82-0XA0 configuration.
  • Module scope: The -25 to +60 °C range applies to the 6ES7157-0AA82-0XA0 interface module.
Description
Within the SIMATIC DP/PA Link, Siemens 6ES7157-0AA82-0XA0 is the IM 157 interface module. The IM 157 works with one or more DP/PA couplers to form the link between the higher-level PROFIBUS DP side and the lower-level PA network.

Communication through 6ES7157-0AA82-0XA0 converts DP V1 access for DP and PA devices. The V4.x module also supports an information function and replacement during operation, allowing the interface position to participate in the documented process-control functions of the link.

Firmware for 6ES7157-0AA82-0XA0 can be updated across the bus. The interface module is specified for an extended operating-temperature range from -25 to +60 °C.
Alternative Names
6ES71570AA820XA0 6ES7157 0AA82 0XA0 6ES7 157-0AA82-0XA0 Siemens 6ES7157 0AA82 0XA0 SIMATIC IM 157 DP PA Link Module 6ES7157-0AA82-0XA0 IM157 6ES7I57-0AA82-0XA0 6ES7157-0AA82-OXA0
Technical notes
Siemens 6ES7157-0AA82-0XA0 is the IM 157 interface module used in a DP/PA Link rather than a stand-alone field coupler. Its V4.x functions include bus-based firmware updating and module replacement during operation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is Siemens 6ES7157-0AA82-0XA0 a complete DP/PA coupler by itself?
No. Siemens 6ES7157-0AA82-0XA0 is the IM 157 interface module; one or more DP/PA couplers are combined with it to form the DP/PA Link.
What communication transition is assigned to 6ES7157-0AA82-0XA0?
The documented role of 6ES7157-0AA82-0XA0 is DP V1 communication to the DP and PA portions of the link.
Can Siemens 6ES7157-0AA82-0XA0 be exchanged while a system is operating?
The V4.x function set for 6ES7157-0AA82-0XA0 includes module replacement during operation.
Where does a firmware update enter 6ES7157-0AA82-0XA0?
Firmware is transferred to 6ES7157-0AA82-0XA0 through the bus, so the target order number and V4.x level must be identified first.
Which ambient operating limit must be checked before installing 6ES7157-0AA82-0XA0?
Siemens specifies 6ES7157-0AA82-0XA0 for -25 to +60 °C operation; the limits of the couplers, bus modules and enclosure still require separate confirmation.