6ES7132-0HH01-0XB0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7132-0HH01-0XB0 is an ET 200B digital output submodule that turns PROFIBUS DP output data into sixteen isolated relay-switched field circuits.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7132-0HH01-0XB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7132-0HH01-0XB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7132-0HH01-0XB0
  • Product Family:
    Siemens Simatic DP
  • Product Type:
    SIMATIC ET 200B 16-Relay Digital Output Submodule
  • Stock:
    1
  • Digital Outputs:
    16 relay outputs; 4 high-current and 12 low-current
  • Required Terminal Block:
    TB6/AC
  • Rated Supply:
    120/230 V AC
  • Permissible Line Frequency:
    47–63 Hz
  • Typical Current Consumption:
    210 mA
  • Typical Power Loss:
    20 W
  • DC Output Voltage Range:
    24–150 V DC
  • Rated AC Output Voltage:
    120/230 V AC
  • Resistive Switching Frequency:
    10 Hz maximum
  • Inductive Switching Frequency:
    2 Hz maximum
  • Resistive Contact Rating:
    4 A maximum; 4 A (2 ports); 2 A (12 ports)
  • Short-Circuit Protection:
    No
  • Maximum Unshielded Cable Length:
    600 m
  • Bus Interface:
    PROFIBUS DP
  • Maximum Bus Rate:
    12 Mbit/s
  • Status Indicators:
    RUN, red BF, and green output LEDs
  • Output Isolation:
    Relay isolation; channels separated individually
  • Protection Rating:
    IP20
  • Horizontal Operating Temperature:
    0 to 60 °C
  • Other Mounting Temperature:
    0 to 40 °C
  • Electrical Connection:
    Screw-type or spring-loaded terminals; permanent 3- or 4-wire wiring
  • Estimated shipping dimensions:
    23.5x13x6cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Relay Channels Load Switching TB6/AC Wiring Status & Bus

Features:

  • Sixteen relay outputs divide into four high-current and twelve standard-current points.
  • Each relay channel is individually isolated from the other output circuits.
  • RUN, BF, and output LEDs separate bus state from commanded contact status.
Siemens 6ES7132-0HH01-0XB0 converts PROFIBUS DP output data into sixteen relay contact operations within an ET 200B station.

The mixed contact ratings in 6ES7132-0HH01-0XB0 assign higher-current loads to two documented points and standard loads to the remaining twelve outputs.

TB6/AC wiring, external load protection, bus status, and channel indicators must be checked together when commissioning 6ES7132-0HH01-0XB0.

The Siemens 6ES7132-0HH01-0XB0 ET 200B Relay Output Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7132-0HH01-0XB0 ET 200B Relay Output Submodule Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Sixteen Individually Isolated Outputs

  • Channel division: The output set contains four high-current and twelve low-current relays rather than sixteen identical contacts.
  • Contact table: Resistive switching is listed at 4 A maximum, with differentiated values of 4 A for two ports and 2 A for twelve ports.
  • Selection rule: Field loads must be assigned from the rating of the actual output position instead of one assumed current value.
  • Isolation structure: Relay separation places every digital output in its own potential group instead of sharing one output potential.

Contact Voltage and Frequency Limits

  • AC circuits: The relay contacts switch documented 120/230 V AC loads independently of the module electronics supply path.
  • DC circuits: DC loads may use the documented 24–150 V DC output-voltage range.
  • Resistive loads: Contact operation with resistive loads is limited to 10 switching cycles per second.
  • Inductive loads: Inductive loads use the lower 2 Hz maximum, so load type changes the permitted switching rate.

Terminal Block and Field Connections

  • Required base: The electronic block operates with the TB6/AC terminal block, which supplies its ET 200B mounting and wiring interface.
  • Terminal styles: Permanent field wiring can use the documented screw-type or spring-loaded terminal construction.
  • Conductor arrangement: The connection design supports permanent three- or four-wire input/output wiring on the terminal block.
  • Cable reach: Unshielded field conductors are specified up to 600 m, subject to the connected load circuit and installation requirements.

PROFIBUS and Output Indication

  • RUN state: The RUN LED confirms the electronic block's operating state independently of individual output commands.
  • Bus fault: The red BF indicator reports a PROFIBUS DP communication fault rather than a load-contact condition.
  • Output state: Green indicators show the commanded state of the digital relay outputs.
  • Protection boundary: Because the contacts have no internal short-circuit protection, a green output indication does not prove that the field load circuit is healthy.
Description
Siemens 6ES7132-0HH01-0XB0 is the SIMATIC DP electronic digital output submodule for an ET 200B station that converts PROFIBUS output data into sixteen isolated relay contact commands. It installs with the documented TB6/AC terminal arrangement and switches AC or DC field circuits independently of the station logic voltage.

The relay bank of 6ES7132-0HH01-0XB0 is not uniform: four points carry the higher documented resistive-load rating, while the other twelve use the standard rating. Field circuits must therefore be assigned to the correct terminals instead of treating all sixteen contacts as interchangeable.

When the DP master updates 6ES7132-0HH01-0XB0, the station maps each output bit to its corresponding relay coil. The dry contact then opens or closes the separately powered load circuit, keeping the switched voltage outside the PROFIBUS electronics path.

Because 6ES7132-0HH01-0XB0 does not provide electronic short-circuit protection, the external branch and connected device determine fault-current protection. Channel LEDs report commanded states, while module diagnostics help separate a station condition from a load-side wiring problem.
Alternative Names
6ES71320HH010XB0 6ES7132 0HH01 0XB0 Siemens 6ES7132-0HH01-0XB0 SIMATIC DP ET 200B 16RO ET 200B 16-relay output module 6ES7132-0HH01-0XB0 electronic block ET200B 120/230 V AC relay module Siemens ET 200B TB6/AC output block
Technical notes
Siemens 6ES7132-0HH01-0XB0 separates sixteen relay outputs into four higher-current points and twelve standard-current points on the TB6/AC arrangement. The contacts are not electronically short-circuit protected, so external branch protection must suit the connected load.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can a green output LED on 6ES7132-0HH01-0XB0 appear while the field load remains off?
The 6ES7132-0HH01-0XB0 LED shows the commanded output state; separately check the TB6/AC wiring, contact supply, load circuit, and external protection.
Why must the load current be checked by channel on 6ES7132-0HH01-0XB0?
The 6ES7132-0HH01-0XB0 divides four high-current and twelve low-current relays and lists different port ratings, so each load must match its actual output position.
What does a red BF indication mean on 6ES7132-0HH01-0XB0?
A red BF LED on 6ES7132-0HH01-0XB0 identifies a PROFIBUS DP fault, so verify the bus connection, station configuration, and communication state.
Why must inductive loads on 6ES7132-0HH01-0XB0 switch more slowly than resistive loads?
The 6ES7132-0HH01-0XB0 contact limit is 2 Hz for inductive loads versus 10 Hz for resistive loads, reflecting the different switching stress.
Does 6ES7132-0HH01-0XB0 protect its relay outputs against a field short circuit?
No. Siemens 6ES7132-0HH01-0XB0 has no internal short-circuit protection, so each load circuit requires protection appropriate to its wiring and rating.