Siemens 6AV3607-1JC00-0AX1 is a SIMATIC OP7/PP operator panel that displays four lines of messages and lets operators select functions or enter numeric and alphanumeric data for S5 and 505 control systems.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6AV3607-1JC00-0AX1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6AV3607-1JC00-0AX1

  • Manufacturer:
    Siemens
  • Part Number:
    6AV3607-1JC00-0AX1
  • Product Family:
    Siemens Simatic HMI
  • Product Type:
    SIMATIC OP7/PP Operator Panel
  • Stock:
    1
  • Display type:
    Black-and-white LC display
  • Display format:
    4 lines; 20 characters per line
  • Backlight:
    LED; 100,000 h MTBF at 25 C
  • Control type:
    Membrane keypad
  • Function keys:
    8
  • Function keys with LEDs:
    4
  • System keys:
    22
  • Keyboard entry:
    Numeric, alphanumeric, and hexadecimal
  • Processor:
    x86
  • User memory:
    128 KB
  • Memory type:
    Flash / RAM
  • Clock:
    Software clock; synchronizable; no battery backup
  • Interfaces:
    1x TTY, 1x RS232, 1x RS422, and 1x RS485
  • Rated supply:
    24 V DC
  • Rated current:
    0.19 A
  • Front protection:
    IP65
  • Rear protection:
    IP20
  • Storage/transport temperature:
    -25 to 70 C
  • Operating humidity:
    95% maximum
  • Operating system:
    Rmos
  • Configuration tool:
    ProTool / Lite V2.51 or higher
  • Approvals:
    CE, GL, BV, DNV, LRS, PRS, FM Class I Div. 2, UL, CSA, cULus, and EX zone 2/22
  • Weight:
    0.948 lbs (0.43 kg)
  • Estimated shipping dimensions:
    14.4x18x3.85cm
  • Tariff Code:
    85371098
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Display and Keys Serial Connections Project Functions Mounting and Protection

Features:

  • A four-line LC display presents twenty characters per line with LED backlighting.
  • Eight function keys and twenty-two system keys separate configured actions from navigation and data entry.
  • TTY, RS232, RS422 and RS485 interfaces provide the serial connection choices for the selected native driver.
The panel forms the operator interface for configured SIMATIC S5 or 505 messages, alarm acknowledgement and recipe handling.

Numeric, alphanumeric and hexadecimal keypad entry lets the project accept different data formats without a touch screen.

Rmos runs the panel project stored in Flash/RAM, while ProTool / Lite V2.51 or higher supplies the configuration environment.

The Siemens 6AV3607-1JC00-0AX1 SIMATIC OP7/PP Operator Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV3607-1JC00-0AX1 SIMATIC OP7/PP Operator Panel Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Four-line message display and keypad

  • Display format: The black-and-white LC display presents four lines with twenty characters on each line.
  • Backlighting: LED illumination has a stated mean time between failures of 100,000 hours at 25 C.
  • Function keys: Eight function keys execute configured actions, and four of them include LED indicators.
  • Data entry: Twenty-two system keys support numeric, alphanumeric and hexadecimal keypad input.

Interfaces for the configured driver path

  • TTY: One TTY interface is available for the communication arrangement selected in the project.
  • RS232: One RS232 interface supplies a separate serial electrical connection.
  • RS422: One RS422 interface provides the differential serial option.
  • RS485: One RS485 interface completes the available serial bus set for the native S5 or 505 driver configuration.

Operating software and configured data

  • Operating system: Rmos runs the operator-panel project on the x86 processor.
  • User memory: The panel provides 128 KB of Flash/RAM memory for user data.
  • Configuration: ProTool / Lite V2.51 or higher is the specified engineering tool.
  • Operator functions: The configuration supports message indication, buffered alarm acknowledgement and recipe management.

Panel dimensions and enclosure limits

  • Housing front: The front measures 144 mm wide by 180 mm high, with an overall depth of 38.5 mm.
  • Mounting: The documented mounting position is vertical with a maximum 90-degree inclination without external ventilation.
  • Protection: The installed front is rated IP65 while the rear of the panel is rated IP20.
  • Environment: Storage and transport are specified from -25 to 70 C, and operating relative humidity is limited to 95 percent.
Description
Siemens 6AV3607-1JC00-0AX1 is a SIMATIC OP7/PP operator panel for SIMATIC S5 and 505 systems with native drivers. It uses a four-line text display and keypad to present configured messages and pass operator selections back to the control project.

The black-and-white LC display on 6AV3607-1JC00-0AX1 shows twenty characters on each of four lines. Eight function keys invoke configured actions, four of those keys include LEDs, and the twenty-two system keys keep navigation and data entry separate from project functions.

Communication for 6AV3607-1JC00-0AX1 is provided through one TTY, one RS232, one RS422 and one RS485 interface. The configured communication path must correspond to the native S5 or 505 driver selected for the panel project.

Project data for 6AV3607-1JC00-0AX1 uses 128 KB of Flash/RAM user memory. Rmos operates the panel, while ProTool / Lite V2.51 or higher configures message indication, buffered alarm acknowledgement and recipe management.

A vertical installation places 6AV3607-1JC00-0AX1 behind a 144 by 180 mm front with an overall depth of 38.5 mm. The installed front is rated IP65, the rear is IP20, and the panel draws 0.19 A from its 24 V DC supply.
Alternative Names
6AV36071JC000AX1 6AV3607 1JC00 0AX1 6AV 3607-1JC00-0AX1 Siemens 6AV3607-1JC00-0AX1 6AV3607-1JC00-0AX1 OP7/PP 6AV3607-1JCOO-OAX1 6AV36O7-1JC00-0AX1 OP7 PP 6AV3607
Technical notes
Siemens 6AV3607-1JC00-0AX1 is the non-touch OP7/PP variant with a four-line, 20-character display and native SIMATIC S5 and 505 drivers.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can I confirm that 6AV3607-1JC00-0AX1 is the required OP7 version?
Siemens 6AV3607-1JC00-0AX1 is identified as the OP7/PP variant with a four-line, 20-character LC display and native drivers for SIMATIC S5 and 505 systems.
6AV3607-1JC00-0AX1 powers up but does not communicate; which interfaces must be matched to the project?
Check whether the 6AV3607-1JC00-0AX1 project uses its TTY, RS232, RS422 or RS485 path and confirm that the selected connection corresponds to the configured S5 or 505 native driver.
Which engineering software is specified for configuring 6AV3607-1JC00-0AX1?
Siemens specifies ProTool / Lite V2.51 or higher for the 6AV3607-1JC00-0AX1 configuration project.
Does 6AV3607-1JC00-0AX1 provide direct process-value display and process-value input functions?
No. The 6AV3607-1JC00-0AX1 data sheet marks process-value display output and process-value default input as unavailable, while message indication, alarm acknowledgement and recipe management are supported.
What enclosure details matter when mounting 6AV3607-1JC00-0AX1?
The 6AV3607-1JC00-0AX1 front measures 144 by 180 mm with a 38.5 mm overall depth; the installed front is IP65 and the rear is IP20.