Features:
- The monochrome display presents four lines with 20 characters per line.
- Eight function keys include four LED-equipped keys for configured operator actions and indications.
- The RS485 interface connects the panel to PROFIBUS DP at rates through 1.5 Mbit/s.
Messages are arranged for the four-line text display, while the membrane keypad separates function selection from numeric and alphabetic entry.
The serial interface set provides RS232, RS422 and RS485 paths, with the RS485 channel serving the documented PROFIBUS DP connection.
The protected front remains accessible to the operator, while the rear connection area is installed inside the control enclosure.
The Siemens 6AV3607-1JC20-0AX1 OP7/DP Operator Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV3607-1JC20-0AX1 OP7/DP Operator Panel Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Text and operator input
- Text layout: The LCD displays four lines with 20 characters on each line.
- Function keys: Eight keys trigger the actions assigned in the configured project.
- LED keys: Four function keys include LEDs for configured visual feedback.
- Data entry: The membrane keyboard accepts both numeric and alphabetic input.
Interface assignment
- RS485 channel: The panel uses this interface for the documented PROFIBUS DP connection.
- RS232 channel: A separate serial path is available for the configured connection.
- RS422 channel: The interface set also includes one RS422 path.
- Port boundary: Industrial Ethernet and USB are not available on this OP7 execution.
Operator project configuration
- Engineering tool: The panel is configured with the supported ProTool/Lite release.
- Function assignment: The project links function keys with the required operator commands.
- Message structure: Text is arranged within the four-line display format.
- Communication setup: The project defines the serial or PROFIBUS connection to the controller.
Front and rear installation boundary
- Front face: IP65 protection applies to the operator side of the installed panel.
- Rear electronics: IP20 applies behind the mounting surface inside the enclosure.
- Mounting direction: The panel is designed for vertical installation.
- Connection area: Power and communication wiring terminate on the protected cabinet side.