C79458-L8001-A77

Siemens C79458-L8001-A77 is a SIMATIC NET CP 5614 PCI processor with separate PROFIBUS DP master and slave interfaces.

In Stock Ships by Wednesday, November 25 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for C79458-L8001-A77

C79458-L8001-A77Siemens SIMATIC NET CP 5614 PROFIBUS PCI Communication Processor
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
C79458-L8001-A77
Product Family
Siemens Simatic Net
Product Type
SIMATIC NET CP 5614 PROFIBUS PCI Communication Processor
Stock
1
Weight
0.375 lbs (0.17 kg)
Tariff Code
8517620090
Country of origin
Germany
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Two isolated RS-485 interfaces separate the PROFIBUS master and slave networks.
  • A 5 V, 32-bit PCI interface connects the processor to the host computer.
  • Internal data transfer can exchange configured process areas between both DP roles.
Siemens C79458-L8001-A77 equips a PCI host with two independent PROFIBUS paths.

The master interface of C79458-L8001-A77 coordinates configured devices while the slave interface exchanges data with an upstream master.

Node addressing and bus termination remain separate for the two connectors.

The Siemens C79458-L8001-A77 SIMATIC NET CP 5614 PROFIBUS PCI Communication Processor may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens C79458-L8001-A77 SIMATIC NET CP 5614 PROFIBUS PCI Communication Processor Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Independent PROFIBUS Roles

  • Master channel: One RS-485 interface controls its configured DP slave stations.
  • Slave channel: The second interface presents process data to an external DP master.
  • Isolation: Both bus connections are electrically isolated from the host.
  • Connectors: Separate 9-pin Sub-D sockets prevent the two networks from sharing a termination point.

Master-to-Slave Exchange

  • Mapping: Configured data areas define which master-side values reach the slave side.
  • Direction: The transfer logic handles data in both configured directions.
  • Host load: Direct exchange avoids routing every cyclic value through the application.
  • Consistency: Area lengths and update settings must agree with both DP configurations.

Computer Interface Boundaries

  • Slot: The board requires a compatible 5 V, 32-bit PCI connection.
  • Power: The host slot supplies the board electronics.
  • Form: The short PCI dimensions must fit the selected computer enclosure.
  • Driver path: The installed communication software must identify the CP 5614 hardware.

Addressing and Termination

  • Addresses: Each PROFIBUS interface uses the node address assigned in its own network.
  • Rate: Every participant on one segment must use the same bus rate.
  • Termination: Active termination is required at the physical ends of each segment.
  • Cabling: Shield continuity and connector orientation must follow PROFIBUS wiring rules.

Description

Siemens C79458-L8001-A77 identifies the SIMATIC NET CP 5614 communication processor for a 5 V, 32-bit PCI slot. It links a host computer to PROFIBUS while keeping one interface for DP master operation and the second interface for DP slave operation.

Two electrically isolated RS-485 channels on C79458-L8001-A77 carry the independent PROFIBUS paths. The master side controls configured field devices, while the slave side presents the host as a participant to another master system.

On-board transfer logic lets C79458-L8001-A77 exchange process data between its master and slave sections without routing every byte through the host application. The configured data areas and bus parameters determine what is transferred between the two PROFIBUS networks.

The short PCI construction of C79458-L8001-A77 occupies a compatible 5 V slot and draws its operating power from the computer bus. Connector assignment, termination, node addresses, and selected DP roles must be set for the two interfaces before cyclic communication begins.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

May
ChinaBently Nevada

Bently Nevada Audit: Zero Discrepancies, USD 25,000 Order

A customer verified Bently Nevada accelerometers, cables and 3500/22M modules at Apter Power. Zero discrepancies led to a USD 25,000 order paid three hours later.

3 hrsOrder to payment
$25,000Follow-up order
“ Apter Power gave us the evidence to approve the expansion with confidence. — Customer procurement manager ”
May · China · 2026
Read the full case study
Jim
ChinaSGS inspection

SGS Verification for Global Automation Procurement

Documented third-party inspection helps procurement teams evaluate supplier processes, product conformity and pre-shipment evidence before cross-border automation orders move forward.

SGS ReviewIndependent evidence
4 StepsClear verification process
“ Verification should show what was checked and how it matches the buyer’s requirements. — Jim ”
Jim · China · 2026
Read the full case study
Miya
ChinaQuality Inspection & Traceability

ISO 9001:2015 Quality Management Certification

Review the ISO 9001:2015 certificate for Apter Power, its certified scope, certificate number, validity, process-control purpose and the limits of management-system certification.

ISO 9001Certified quality system
TraceableDocumented order records
“ Certification matters only when the process is visible in everyday work—from the first requirement review to the final release. — Miya ”
Miya · China · August 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why does C79458-L8001-A77 operate as a master but not as a slave?

Check the C79458-L8001-A77 second-interface address, slave configuration, input and output lengths, connector, bus rate, and upstream master project.

How are two PROFIBUS cables assigned on C79458-L8001-A77?

Connect the master network and slave network to their documented C79458-L8001-A77 interfaces; the ports do not share one bus role.

What prevents direct data transfer through C79458-L8001-A77?

Compare the C79458-L8001-A77 mapped data areas, direction, lengths, consistency settings, active DP states, and application configuration.

Why is C79458-L8001-A77 not detected in a computer?

Confirm a compatible 5 V, 32-bit PCI slot for C79458-L8001-A77, firm seating, host power, device driver, and operating-system support.

What causes intermittent stations on one C79458-L8001-A77 bus only?

Inspect that C79458-L8001-A77 interface cable, termination, node addresses, shielding, connectors, rate, and segment length independently of the other bus.

Can both interfaces of C79458-L8001-A77 be connected to the same PROFIBUS segment?

C79458-L8001-A77 defines separate master and slave interfaces; configure and cable each role according to the intended network topology.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6GK1905-0AE00
6GK1905-0AE00 is a PROFIBUS PA SpliTConnect terminator for terminating PROFIBUS PA segments; not suitable for use in hazardous areas.
6GK1571-0BA00-0AA0
The 6GK1571-0BA00-0AA0 PC Adapter USB A2 is a compact and reliable communication interface for connecting a computer to PROFIBUS networks via a USB port.
6NH9720-3AA00
The 6NH9720-3AA00 is a Siemens SIMATIC NET SINAUT MD720-3 GSM/GPRS modem with RS232 interface, quadband GSM support, and AT command interface for remote communication.
6GK1161-3AA00
Siemens 6GK1161-3AA00 is a SIMATIC NET CP 1613 PCI communication processor that gives a PC system Industrial Ethernet and S7 communication access.
In stock
6GK1411-2AB10
Siemens 6GK1411-2AB10 is an IE/AS-i Link PN IO gateway that connects one AS-Interface master network to PROFINET IO through two Industrial Ethernet ports.
In stock
6GK1417-5AB00
Siemens 6GK1417-5AB00 is an industrial wireless communication gateway that connects PROFIBUS field devices to a PROFINET IO system over IWLAN.
In stock
6GK1503-3CA00
Siemens 6GK1503-3CA00 is a PROFIBUS OLM/P12 V4.0 optical link module with one RS485 channel and two POF/PCF fiber channels.
In stock
C79458-L8001-A77
Siemens C79458-L8001-A77 is a SIMATIC NET CP 5614 PCI processor with separate PROFIBUS DP master and slave interfaces.
In stock
6ES7972-0BA12-0XA0
Siemens 6ES7972-0BA12-0XA0 is a PROFIBUS RS485 bus connector that joins a screw-terminated cable to a 9-pin interface at rates up to 12 Mbit/s.
In stock
6GK1905-0FA00
Siemens 6GK1905-0FA00 is a five-piece pack of field-assembled 7/8-inch, five-pole male connectors with axial cable outlets for ET 200 power wiring.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat