Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 6ES7277-0AA22-0XA0

All in stock · Add one and it is quoted together with the model, one shipping cost.

6ES7277-0AA22-0XA0

6ES7277-0AA22-0XA0

Siemens 6ES7277-0AA22-0XA0 is an EM 277 communication module that connects an S7-200 station to PROFIBUS-DP or MPI through one isolated RS485 interface.

In Stock Ships by Thursday, November 26 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 6ES7277-0AA22-0XA0

6ES7277-0AA22-0XA0Siemens SIMATIC S7-200 EM 277 PROFIBUS-DP Slave Module
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
6ES7277-0AA22-0XA0
Product Family
Siemens Simatic S7-200
Product Type
SIMATIC S7-200 EM 277 PROFIBUS-DP Slave Module
Stock
1
Weight
0.324 lbs (0.147 kg)
Estimated shipping dimensions
10.1x8.8x7.1cm
Tariff Code
8517620000
Country of origin
China
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • One isolated RS485 interface supports PROFIBUS-DP slave and MPI slave roles.
  • Automatic rate detection covers supported network speeds through 12 Mbit/s.
  • Separate PWR, BF, CPU, and DX indicators divide power, controller, bus, and exchange states.
The 24 V DC and backplane supplies of 6ES7277-0AA22-0XA0 serve different module circuits.

Address and protocol configuration on 6ES7277-0AA22-0XA0 determine the active network role.

Speed-dependent segment length and termination govern the external RS485 path of 6ES7277-0AA22-0XA0.

The Siemens 6ES7277-0AA22-0XA0 SIMATIC S7-200 EM 277 PROFIBUS-DP Slave Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7277-0AA22-0XA0 SIMATIC S7-200 EM 277 PROFIBUS-DP Slave Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Slave Data Transfer Path

  • Master request: The PROFIBUS master initiates cyclic exchange with the configured EM 277 node.
  • Data mapping: Configured bytes move between the network telegram and S7-200 memory.
  • Node address: The selected address identifies the slave within the permitted network range.
  • DX state: The front indicator shows whether data exchange is active.

Service and Peer Communication

  • Shared port: MPI slave communication uses the same physical RS485 interface.
  • Connections: The module supports the documented number of simultaneous MPI connections.
  • Partner setup: Peer address, rate, cable, and protocol must agree with the module configuration.
  • Role boundary: MPI service exchange is distinct from PROFIBUS-DP cyclic slave mapping.

RS485 Segment Conditions

  • Speed and length: Higher rates require the shorter cable lengths defined for PROFIBUS.
  • Termination: Both ends of an RS485 segment use the required active termination.
  • Shielding: The cable shield and connector follow the industrial bus grounding arrangement.
  • Station count: Segment and network node totals remain within the documented limits.

Front-State Separation

  • PWR: The supply indicator confirms that module power is present.
  • BF: The bus-fault indicator identifies a missing or invalid network exchange.
  • CPU error: The controller indicator separates an S7-200 problem from a cable-only fault.
  • DX: The data-exchange indicator reports the configured communication state.

Description

Siemens 6ES7277-0AA22-0XA0 is a SIMATIC S7-200 EM 277 PROFIBUS-DP slave module that links the controller station with a PROFIBUS-DP master or supported MPI partners. Its RS485 interface transfers process and service data while the S7-200 expansion bus exchanges that data with the CPU.

The communication interface of 6ES7277-0AA22-0XA0 detects the configured network rate across the supported 9.6 kbit/s to 12 Mbit/s range. Cable length therefore depends on the selected speed, and the bus connector, shielding, node address, and segment termination must match the complete PROFIBUS installation.

DP slave operation on 6ES7277-0AA22-0XA0 maps configured input and output data between the master and S7-200 memory, while MPI slave operation provides a different communication role through the same physical interface. The configured protocol determines which partner and data path are active.

External 24 V DC power enters 6ES7277-0AA22-0XA0 separately from the 5 V expansion-bus supply. The isolated RS485 side and the logic side use the documented test boundary so network wiring does not share the same electrical path as the controller electronics.

Front indicators on 6ES7277-0AA22-0XA0 distinguish supply presence, bus faults, CPU errors, and data-exchange conditions. This separation helps determine whether a stopped exchange originates at module power, the S7-200 CPU, the PROFIBUS segment, or the configured master.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Leonia
IndonesiaBently Nevada 3500/22M 288055-01

On-Site Verification for an Indonesian Power Plant

After a previous suspected-counterfeit purchase, an Indonesian power-plant customer used a 50/50 payment plan, visited Apter Power to inspect two Bently Nevada 3500/22M 288055-01 modules, requested COO documentation and approved next-day hotel delivery.

100%Modules inspected on site
50/50Deposit / balance after inspection
“ They are very professional and supply quality products. I have purchased Bently Nevada products from them and had a very good experience. — Tri ”
Leonia · Indonesia · May 2026
Read the full case study
May
ChinaBently Nevada

Bently Nevada Audit: Zero Discrepancies, USD 25,000 Order

A customer verified Bently Nevada accelerometers, cables and 3500/22M modules at Apter Power. Zero discrepancies led to a USD 25,000 order paid three hours later.

3 hrsOrder to payment
$25,000Follow-up order
“ Apter Power gave us the evidence to approve the expansion with confidence. — Customer procurement manager ”
May · China · 2026
Read the full case study
Miya
ChinaQuality Inspection & Traceability

ISO 9001:2015 Quality Management Certification

Review the ISO 9001:2015 certificate for Apter Power, its certified scope, certificate number, validity, process-control purpose and the limits of management-system certification.

ISO 9001Certified quality system
TraceableDocumented order records
“ Certification matters only when the process is visible in everyday work—from the first requirement review to the final release. — Miya ”
Miya · China · August 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why does 6ES7277-0AA22-0XA0 show BF after a network change?

Compare the 6ES7277-0AA22-0XA0 node address, master configuration, baud rate, cable, connector termination, shield, and segment power.

What separates a CPU error from a PROFIBUS fault on 6ES7277-0AA22-0XA0?

Use the 6ES7277-0AA22-0XA0 CPU and BF indicators together, then check the S7-200 state and the external bus independently.

How is 6ES7277-0AA22-0XA0 data mapped into S7-200 memory?

Configure the 6ES7277-0AA22-0XA0 DP data length and S7-200 memory offset so the master telegram and controller addresses correspond.

Why does 6ES7277-0AA22-0XA0 communicate at a low rate but fail at 12 Mbit/s?

Inspect the 6ES7277-0AA22-0XA0 cable type, segment length, connectors, termination, shielding, stubs, and master timing for the higher rate.

Can 6ES7277-0AA22-0XA0 run PROFIBUS-DP and MPI mapping as the same connection?

No. Configure the 6ES7277-0AA22-0XA0 for the required slave role because DP cyclic mapping and MPI service communication are different functions.

What should be checked when 6ES7277-0AA22-0XA0 has power but no DX indication?

Verify the 6ES7277-0AA22-0XA0 CPU state, protocol, node address, master project, configured data size, and RS485 segment.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6ES7221-1BF22-0XA8
The 6ES7221-1BF22-0XA8 is a Siemens SIMATIC S7-200 digital input module with 8 DC inputs, 4 mA typical input current, 2 W power loss, and compact dimensions of 46 x 80 x 62 mm.
6ES7235-0KD22-0XA0
The Siemens 6ES7235-0KD22-0XA0 is a reliable SIMATIC S7-200 analog expansion module designed exclusively to enhance the processing capabilities of S7-22X CPU control systems.
In stock
6ES7288-1ST20-0AA1
Siemens 6ES7288-1ST20-0AA1 CPU ST20: 12 DI 24 VDC and 8 transistor outputs, 0.75 A; 20.4-28.8 VDC; PROFINET/Ethernet and RS-485.
In stock
6ES7288-2DR08-0AA0
Siemens 6ES7288-2DR08-0AA0 SM DR08: 8 relay outputs, 2 A; 20.4-28.8 VDC; S7-200 SMART expansion bus.
In stock
6ES7288-2DT08-0AA0
Siemens 6ES7288-2DT08-0AA0 SM DT08: 8 transistor outputs, 24 VDC, 0.75 A; 20.4-28.8 VDC; S7-200 SMART expansion bus.
In stock
6ES7288-5AQ01-0AA0
Siemens 6ES7288-5AQ01-0AA0 SB AQ01 Analog Output Board: 1 analog output for voltage or current.
In stock
6ES7288-6EC01-0AA0
Siemens 6ES7288-6EC01-0AA0 I/O Expansion Cable: 1 m cable for documented SMART expansion connections.
In stock
6ES7272-0AA30-0YA1
Configured from an S7-200 parameter block, Siemens 6ES7272-0AA30-0YA1 is a two-line TD 200 text display for operator screens and CPU-triggered alarms.
In stock
6ES7214-2AD23-0XB0
Siemens 6ES7214-2AD23-0XB0 is an S7-200 CPU 224XP compact controller with 14 digital inputs, 10 transistor outputs, two analog inputs, and one analog output.
In stock
6ES7221-1BF22-0XA0
Siemens 6ES7221-1BF22-0XA0 is an S7-200 EM 221 digital input module that converts eight 24 V DC sink/source field states into controller input bits.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history