Siemens 6DR5610-0NG00-0AA0 is a single-acting SIPART PS2 FOUNDATION Fieldbus positioner for pneumatic linear or part-turn control valves in non-Ex areas.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 6DR5610-0NG00-0AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6DR5610-0NG00-0AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6DR5610-0NG00-0AA0
  • Product Family:
    Siemens Sipart
  • Product Type:
    Electropneumatic Positioner
  • Stock:
    1
  • Measurement / Function:
    valve position
  • Output / Command Signal:
    Digital fieldbus
  • Communication / Control Interface:
    FOUNDATION Fieldbus
  • Selected Span / Torque Class:
    Actuator travel established by initialization
  • Configurable Range / Travel:
    Linear or part-turn travel within the selected mounting geometry
  • Process / Pneumatic Connection:
    G1/4
  • Wetted / Service Materials:
    Instrument-air pneumatic components
  • Bolting / Mechanical Interface:
    Mounting-kit dependent
  • Installation Arrangement:
    Single-acting linear or part-turn actuator mounting
  • Housing:
    Polycarbonate enclosure
  • Electrical Connection:
    M20×1.5
  • Local Indicator:
    Two-line local display
  • Mounting Hardware:
    Actuator-specific mounting kit
  • Ordering Options:
    No limit monitor, option module, manometer block or booster.
  • Degree of Protection:
    Per exact SIPART PS2 enclosure and entry installation
  • Ambient Conditions:
    Per exact protection and certification variant
  • Process / Service Temperature:
    Not a pressure-transmitter process-wetted specification
  • Communication Load / I/O:
    Per selected analog or fieldbus interface
  • Stability / Control Performance:
    Control behavior established by automatic initialization
  • Manufacturer Reference:
    Siemens Process Instrumentation Selection Catalog 2016 and the exact Siemens product record
  • Tariff Code:
    90328100
  • Country of origin:
    France
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Communication Temperature Monitoring

Features:

  • Controls single-acting pneumatic actuators through M20×1.5 and G1/4 connections in a non-explosion-protected construction.
  • Accepts digital fieldbus with FOUNDATION Fieldbus while retaining the selected single-acting output stage.
  • The selected assembly uses a polycarbonate enclosure with automatic initialization and no explosion protection.
The supplied 6DR5610-0NG00-0AA0 variant is distinguished by single-acting FOUNDATION Fieldbus interface in a non-Ex enclosure.

It compares the controller command with valve travel and meters instrument air so the connected actuator follows the requested position.

Match fieldbus segment design, single-acting stage or non-Ex classification to the existing assembly before wiring, pressurization or actuator movement.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Siemens 6DR5610-0NG00-0AA0: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • The single-acting FOUNDATION Fieldbus valve-positioning configuration positions pneumatic control valves used in flow, pressure, temperature or level-regulation loops.
  • The single-acting FOUNDATION Fieldbus valve-positioning configuration supports compatible linear and part-turn actuators when action, linkage geometry and air supply are engineered correctly.
  • The single-acting FOUNDATION Fieldbus valve-positioning configuration provides local commissioning and valve-condition diagnostics for a verified actuator and control-system interface.
  • The positioner exchanges setpoint, position and diagnostic data through a FOUNDATION Fieldbus segment.
  • Segment power, addressing, polarity and terminators must be verified before the device is brought online.
  • The control host must use a compatible device description and function-block configuration for commissioning.
  • Ambient use follows the temperature limits assigned to the non-explosion-protected polycarbonate-housing variant.
  • Supply-air temperature and dew point must prevent condensation or icing inside pneumatic passages.
  • The non-Ex construction does not carry a hazardous-area temperature class; apply only the stated ambient limits.
  • The local display provides position, status and commissioning feedback during valve operation.
  • Remote status is available through FOUNDATION Fieldbus where supported by the exact interface.
  • Trend review should compare command, travel response and control deviation to identify developing friction.
Description
6DR5610-0NG00-0AA0 defines the ordered SIPART PS2 electropneumatic positioner for single-acting actuator control. The exact article number governs every replacement decision.

It compares the controller command with valve travel and meters instrument air so the connected actuator follows the requested position. It is intended for pneumatic control-valve positioning on a correctly engineered linear or part-turn actuator with the correct linkage, air supply and control-system interface.

Commissioning must begin with the valve in a safe state. Validate fieldbus segment design, single-acting stage or non-Ex classification, tubing, linkage and travel limits before automatic initialization.
Alternative Names
6DR5610-0NG00-0AA0 Siemens 6DR5610-0NG00-0AA0 6DR5610 0NG00 0AA0 6DR56100NG000AA0 Siemens SIPART PS2 Smart Electropneumatic Positioner Siemens 6DR5610-0NG00-0AA0 Smart Electropneumatic Positioner Siemens Article No. 6DR5610-0NG00-0AA0
Technical notes
Check fieldbus segment power, addressing and termination before energization; initialization can move the single-acting valve through full travel even with communications incomplete.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which digital protocol is native to 6DR5610-0NG00-0AA0?
This order is the FOUNDATION Fieldbus version of SIPART PS2. It is not a conventional HART command variant and must be engineered as a fieldbus device.
What segment checks are required before 6DR5610-0NG00-0AA0 joins a FOUNDATION Fieldbus network?
Verify the host device files, segment power, terminators, trunk and spur loading, hazardous-area concept and the control strategy assigned to the positioner.
What actuator service is appropriate for 6DR5610-0NG00-0AA0?
It operates a single-acting linear or part-turn pneumatic actuator when the mechanical kit, spring action, supply pressure and initialized travel are correct.
What should a purchaser specify about firmware when sourcing 6DR5610-0NG00-0AA0?
Provide the host system version and any installed-device firmware requirement, then request confirmation that the offered unit is supported by the available device description files.
Why is an analog SIPART PS2 not a functional substitute for 6DR5610-0NG00-0AA0?
An analog unit cannot assume the FOUNDATION Fieldbus address, function blocks or segment communication expected by the control system, even if the housing and actuator mounting look similar.
Which network documents should be attached to a 6DR5610-0NG00-0AA0 quotation request?
Include the segment drawing, host name and revision, required device files and actuator data together with the exact Siemens order number, quantity and delivery country.