86517-XX-XX-01-02 MOD 159840-1

/ 4.9
1001 reviews | Need a Specific Revision?
The Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 is a modified 86517 Dynamic Pressure Interface Module identified by its full marked order code for compatible three-wire aeroderivative monitoring applications.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 86517-XX-XX-01-02 MOD 159840-1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 86517-XX-XX-01-02 MOD 159840-1

  • Manufacturer:
    Bently Nevada
  • Part Number:
    86517-XX-XX-01-02 MOD 159840-1
  • Product Family:
    3300 System
  • Product Type:
    Dynamic Pressure Interface Module
  • Stock:
    1
  • Signal Application:
    Dynamic pressure measurement
  • Interface Form:
    Modified 86517 I/F
  • Field Connection:
    3-Wire (Com/Sig/-24 VDC)
  • Compatible Input Modules:
    PAA and PAV
  • Channel Support:
    PAA/PAV channels 1-6
  • Monitor Platform:
    3701/44 ADAPT Aeroderivative Monitor
  • Configurable Measurements:
    Pressure, bandpass, and bias
  • Tariff Code:
    90318090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Signal Path Measurements Integration

Features:

  • Interface form: Modified 86517 interface for dynamic-pressure input applications.
  • Field connection: Three-wire path using common, signal, and -24 VDC conductors.
  • Monitor inputs: Compatible PAA and PAV channels on the 3701/44 ADAPT platform.
The 3701/44 ADAPT monitor provides dynamic-pressure channel types on PAA and PAV channels 1 through 6, forming the applicable monitor path for the modified 86517 interface family.

Pressure-channel setup can include full-scale range, pressure units, high- and low-pass filters, filter order, amplitude clamps, bandpass processing, and bias measurements.

For 86517-XX-XX-01-02 MOD 159840-1, retain the complete MOD marking and confirm common/signal/-24 VDC wiring, selected input hardware, grounding, channel settings, and approval requirements.

Availability is subject to Apter Power inventory and sourcing confirmation.
Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 Dynamic Pressure Interface Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 Dynamic Pressure Interface Module Specs

General

  • ManufacturerBently Nevada
  • Model86517-XX-XX-01-02 MOD 159840-1
  • ConditionNew Original ready stock
  • Product Family3300 System
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Dynamic Pressure Connection

  • Field conductors: The official compatibility table specifies a three-wire common, signal, and -24 VDC connection.
  • PAA input: PAA channels can receive the modified 86517 interface for dynamic-pressure measurement.
  • PAV input: PAV channels provide the same documented three-wire modified-interface path.
  • Interface alternative: The table lists either a 350500 DPCA or a modified 86517 interface for this connection.

Pressure Channel Configuration

  • Pressure range: Configure full scale and select psi or mbar peak-to-peak, dpp, or rms units.
  • Filtering: Set high- and low-pass corner frequencies, filter order, and amplitude clamp values.
  • Bandpass: Define bandpass full scale, units, filter corners, filter order, and clamp value.
  • Bias: Apply the documented low-pass corner setting for the dynamic-pressure bias measurement.

Monitor and Channel Review

  • Monitor platform: The modified interface is documented in the 3701/44 ADAPT Aeroderivative Monitor compatibility table.
  • Channel allocation: PAA and PAV channels 1 through 6 support the dynamic-pressure channel type.
  • Configuration: Use the selected channel's documented measurement, filtering, and clamp settings.
  • Identity check: Preserve the complete 86517-XX-XX-01-02 MOD 159840-1 marking during replacement review.
Description
86517-XX-XX-01-02 MOD 159840-1 carries the modified 86517 designation used in aeroderivative dynamic-pressure signal chains. The 86517 interface family uses a three-wire common, signal, and -24 VDC connection, while the complete MOD 159840-1 marking must be retained for exact replacement identification.

Within compatible 3701/44 ADAPT configurations, 86517-XX-XX-01-02 MOD 159840-1 may be applied with PAA or PAV input modules after the installed MOD configuration and channel hardware are confirmed. PAA and PAV channels provide pressure, bandpass, and bias measurement functions for combustion-dynamics and machinery-protection applications.

Replacement review for 86517-XX-XX-01-02 MOD 159840-1 must match the full nameplate code, three-wire polarity, input-module type, monitor configuration, filters, grounding, and approval requirements. A generic 86517 assembly should not be substituted solely from the base number.
Alternative Names
86517 XX XX 01 02 MOD 159840 1 86517XXXX0102MOD1598401 Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 Bently-Nevada 86517-XX-XX-01-02 MOD 159840-1 BN 86517-XX-XX-01-02 MOD 159840-1 86517 MOD 159840-1 Dynamic Pressure Interface Modified 86517 Dynamic Pressure Interface Module 86517 159840-1 Datasheet
Technical notes
Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 retains the complete MOD marking of a modified 86517 interface. Confirm the installed MOD configuration before applying three-wire dynamic-pressure and PAA/PAV family data.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which signal connection should be checked for 86517-XX-XX-01-02 MOD 159840-1?
The modified 86517 interface family associated with 86517-XX-XX-01-02 MOD 159840-1 uses a three-wire path of common, signal, and -24 VDC.
Which input-module family is relevant to 86517-XX-XX-01-02 MOD 159840-1?
The modified 86517 signal path associated with 86517-XX-XX-01-02 MOD 159840-1 uses compatible PAA or PAV inputs after the installed MOD configuration is confirmed.
Which measurement application is associated with 86517-XX-XX-01-02 MOD 159840-1?
Bently Nevada 86517-XX-XX-01-02 MOD 159840-1 retains the modified 86517 identity used for dynamic-pressure measurements, but the complete MOD marking must match the installed hardware.
Can 86517-XX-XX-01-02 MOD 159840-1 be matched by the base 86517 number alone?
No. Retain the complete 86517-XX-XX-01-02 MOD 159840-1 marking and verify the dynamic-pressure wiring and monitor configuration.
What lifecycle status is currently used for 86517-XX-XX-01-02 MOD 159840-1?
Apter Power lists 86517-XX-XX-01-02 MOD 159840-1 as Active / Available from OEM because no explicit EOL notice was found for the complete marked assembly.
What should be checked before installing 86517-XX-XX-01-02 MOD 159840-1?
Before installing 86517-XX-XX-01-02 MOD 159840-1, confirm common/signal/-24 VDC wiring, grounding, channel type, filters, and approvals.
Where can customers request documentation or a quotation for 86517-XX-XX-01-02 MOD 159840-1?
Apter Power can provide official-document review, configuration support, sourcing assistance, and quotation service for 86517-XX-XX-01-02 MOD 159840-1.