Features:
- Generates a 100 pC/g charge signal over a 0.01 to 400 g peak dynamic range.
- Uses a sealed austenitic stainless-steel body with an integral 3 m protected cable.
- Maintains the specified ±5% response from 0.5 to 6000 Hz with the matching charge converter.
The selected ordering configuration combines the CA202 sensor head with the manufacturer-listed 3 m integral cable.
Its wide temperature capability and sealed construction suit long-term vibration protection where powered electronics cannot be placed at the measuring point.
Verify mounting torque, sensitive-axis orientation, cable temperature, connector insulation and the IPC70x input before commissioning.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 144-202-000-206:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures casing vibration on steam, gas and hydro turbines operating near elevated process temperatures.
- Feeds charge-based protection and monitoring channels on compressors, generators and other critical rotating assets.
- Supports permanent installations exposed to steam, oil, salt atmosphere and high relative humidity when mounted correctly.
- The two-pin charge output is electrically insulated from the sensor case to reduce grounding conflicts.
- An IPC70x charge converter supplies the required signal conditioning outside the accelerometer body.
- Nominal sensor and cable capacitance must be included when checking the complete measurement-chain input.
- The sensing head operates continuously from -55 to +260°C and survives short exposure to +280°C.
- Its integral cable is limited to +200°C in continuous service and +250°C for short-term survival.
- Temperature gradients should be managed so the cable transition is not exposed to sensor-level heat.
- The welded sensor and protection hose form a leak-tight assembly for 100% relative humidity.
- Stainless-steel construction resists water, steam, oil and sea-salt atmospheres.
- The sealed assembly also excludes dust, fungus and sand from the measurement element.