Features:
- Matches the TQ4X3 probe for a 12 mm nominal measuring range.
- Provides 1.33 mV/µm sensitivity through a standard three-wire voltage output.
- Uses the 5 m matched cable ordering option shown for this conditioner.
The selected signal conditioner is 204-453-000-011, the IQS453 entry paired with TQ4X3, 12 mm range and 5 m cable.
The 12 mm measurement range targets larger shaft-clearance movement while the HF eddy-current chain retains DC response for static gap and dynamic vibration observation.
Do not substitute the shorter-range IQS451 or IQS452 calibration; the TQ4X3 probe and 1.33 mV/µm sensitivity define this chain.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 204-453-000-011:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures relative shaft vibration and static gap without contacting the rotating surface.
- Conditions proximity signals for turbine, compressor, pump and generator monitoring systems.
- Feeds rack processor modules with a temperature-compensated output scaled to probe movement.
- The matched TQ4X3 chain measures up to 12 mm of probe-to-target gap movement.
- DC response supports static gap observation as well as dynamic shaft displacement.
- Interchangeability is specified within five percent when the matched probe, cable and conditioner chain is preserved.
- The conditioner response extends from DC to 20 kHz at the -3 dB point.
- A 1.33 mV/µm voltage scale converts target movement into the three-wire output.
- The eddy-current principle measures movement without physical contact with the target.
- Normal operation is specified from -30 to +70°C.
- The potted aluminium housing is rated IP40 and resists dust and moisture ingress inside a suitable enclosure.
- Operation and storage allow up to 95% relative humidity without condensation.