Features:
- Four independently programmable dynamic measurement channels.
- Two tachometer inputs for speed and phase-reference processing.
- On-board DSP for continuously online machinery protection calculations.
The current ordering configuration is VM600 MPC4 200-510-070-113, an earlier-generation protection processor for a VM600 rack.
It evaluates configured vibration and speed measurements and participates in alert, danger and channel-health functions.
Before replacement, verify the paired IOC4T version, buffered-output impedance, rack database and slot assignment.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter VM600 MPC4 200-510-070-113:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
VIBRO-METER VM600 MPC4 200-510-070-113 4-Channel Machinery Protection Card Specs
General
- Manufacturer VIBRO-METER
- Model VM600 MPC4 200-510-070-113
- Condition New Original ready stock
- Product Family
VM600 MPC4 200-510-076-114,VM600 MPC4 200-510-041-021
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
- Protects turbines, compressors, generators and large pumps with continuously evaluated vibration channels.
- Uses speed and phase references for configured rotating-machine measurement functions.
- Supports commissioning and analysis through accessible buffered channel signals.
- Processes four dynamic inputs and two tachometer references in real time.
- Applies configured filters, scaling, alert and danger logic for each measurement path.
- Exchanges status and configuration through the VM600 rack control architecture.
- Supervises sensor and channel health for the configured measurement chains.
- Provides buffered signals for external checks without changing the protection calculation.
- Requires validation of alarms, relays and channel scaling after any card exchange.