Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides MPC4 200-510-070-113 quotes, documents, sourcing and IOC4T matching.

VM600 MPC4 200-510-070-113

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter VM600 MPC4 200-510-070-113 is a four-channel machinery protection card with two tachometer inputs and onboard signal processing. It operates in a VM600 rack with the matching rear I/O card.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for VM600 MPC4 200-510-070-113
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for VM600 MPC4 200-510-070-113

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    VM600 MPC4 200-510-070-113
  • Product Family:
    VM600 Machinery Protection System
  • Product Type:
    4-Channel Machinery Protection Card
  • Stock:
    1
  • Dynamic Input Channels:
    4
  • Tachometer Inputs:
    2
  • Voltage Input Range:
    0 to +20 VDC or 0 to -20 VDC
  • AC Input Limit:
    ±10 V
  • Analog Bandwidth:
    DC to 60 kHz
  • Input Impedance:
    200 kΩ
  • Common-Mode Range:
    ±50 V
  • CMRR:
    Greater than 60 dB at 50 Hz
  • Channel Crosstalk:
    -72 dB
  • Amplitude Accuracy:
    ±1% of full scale
  • Current Input Range:
    0 to 25 mA DC
  • Processing:
    On-board DSP measurement processing
  • Card Format:
    6U rack card
  • Dimensions:
    262 x 20 x 187 mm
  • Operating Temperature:
    -25 to +65 °C
  • Mass:
    Approximately 0.40 kg
  • Weight:
    0.882 lbs (0.4 kg)
  • Estimated shipping dimensions:
    2 x 19 x 26.1 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Monitoring & Control Diagnostics & Protection

Features:

  • Four independently programmable dynamic measurement channels.
  • Two tachometer inputs for speed and phase-reference processing.
  • On-board DSP for continuously online machinery protection calculations.
The current ordering configuration is VM600 MPC4 200-510-070-113, an earlier-generation protection processor for a VM600 rack.

It evaluates configured vibration and speed measurements and participates in alert, danger and channel-health functions.

Before replacement, verify the paired IOC4T version, buffered-output impedance, rack database and slot assignment.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter VM600 MPC4 200-510-070-113:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
VIBRO-METER VM600 MPC4 200-510-070-113 4-Channel Machinery Protection Card Specs

General

  • Manufacturer VIBRO-METER
  • Model VM600 MPC4 200-510-070-113
  • Condition New Original ready stock
  • Product Family VM600 MPC4 200-510-076-114,VM600 MPC4 200-510-041-021
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Protects turbines, compressors, generators and large pumps with continuously evaluated vibration channels.
  • Uses speed and phase references for configured rotating-machine measurement functions.
  • Supports commissioning and analysis through accessible buffered channel signals.
  • Processes four dynamic inputs and two tachometer references in real time.
  • Applies configured filters, scaling, alert and danger logic for each measurement path.
  • Exchanges status and configuration through the VM600 rack control architecture.
  • Supervises sensor and channel health for the configured measurement chains.
  • Provides buffered signals for external checks without changing the protection calculation.
  • Requires validation of alarms, relays and channel scaling after any card exchange.
Description
VM600 MPC4 200-510-070-113 is a 6U machinery protection card that accepts four dynamic measurement channels and two tachometer inputs, with onboard DSP processing for the configured protection functions.

The card processes vibration, position and speed-related signals inside a VM600 rack and supplies the measurement and alarm data required by machinery protection applications.

Confirm the monitored signal type, rack configuration, firmware and matching IOC4T rear card before replacement. Preserve channel scaling, alarm logic and rack-slot assignments during commissioning.
Alternative Names
Vibro-Meter VM600 MPC4 200-510-070-113 VM600 MPC4 200 510 070 113 VM600-MPC4-200-510-070-113 200510070113 Vibro-Meter machinery protection card 200-510-070-113 MPC4 four-channel protection module VM600 vibration monitoring card MPC4 6U machinery protection processor
Technical notes
For VM600 MPC4 200-510-070-113, verify the paired IOC4T generation and buffered-output impedance before replacement; incompatible card pairing can invalidate monitoring channels.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How are the four channels on VM600 MPC4 200-510-070-113 used?
Each dynamic channel is configured for its assigned vibration or process measurement path within the VM600 protection database.
What does VM600 MPC4 200-510-070-113 use the two tachometer inputs for?
They provide speed and phase references used by configured machinery measurements and protection functions.
Which rack components must match VM600 MPC4 200-510-070-113?
Confirm the associated IOC4T hardware, rack slot, software configuration and relay architecture before installation.
Can Apter Power quote VM600 MPC4 200-510-070-113 only after its paired IOC4T revision is identified?
The IOC4T part number, rack slot, hardware revision, buffered-output requirement and quantity should accompany the quotation request.
What is the main replacement risk for VM600 MPC4 200-510-070-113?
Early and later MPC4/IOC4T versions can differ in buffered-output behavior, so the paired assembly must be reviewed.
How can a buyer obtain VM600 MPC4 200-510-070-113 manuals and pricing?
Send the full part number, IOC4T pairing, rack details and quantity for document matching and quotation.