AAR145-S03 S1

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa AAR145-S03 S1 is a 16-channel isolated RTD/POT input module for Yokogawa FIO systems. It accepts 3-wire Pt100 RTD and potentiometer signals, with input type selected independently by channel.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for AAR145-S03 S1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for AAR145-S03 S1

  • Manufacturer:
    Yokogawa
  • Part Number:
    AAR145-S03 S1
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    RTD/POT Input Module
  • Stock:
    1
  • Input Channels:
    16
  • Supported RTD:
    JIS Pt100 Ω
  • Potentiometer Range:
    100 Ω to 10 kΩ total resistance; span resistance at least 50% of total
  • Channel Isolation:
    Isolated channels
  • RTD Lead Matching:
    IN A and IN C signal-wire resistance must be equal
  • Listed Terminal Configurations:
    KS8 with MRT/TERT; AKB335 with AER4D
  • Channel Input Mapping:
    A, B and C terminals per input
  • Potentiometer Span Resistance:
    At least 50% of total resistance
  • Allowable Input Voltage:
    ±5 V
  • Input-to-System Withstand:
    500 V AC for 1 minute; 1500 V AC for a single card
  • Between-Channel Withstand:
    200 V AC for 1 minute
  • Input Resistance:
    At least 1 MΩ, power on and power off
  • RTD Accuracy:
    ±150 mΩ
  • POT Accuracy:
    ±0.2% of full scale
  • RTD Wiring Resistance:
    150 Ω maximum per wire; IN A and IN C resistance equal
  • Data Update Period:
    1 s
  • Burnout Detection:
    Settable for all channels together; 60 s detection time
  • Temperature Drift:
    RTD: ±0.3 Ω/10 °C; POT: ±0.4%/10 °C
  • Maximum Current Consumption:
    350 mA at 5 V DC
  • Operating Temperature Option:
    -20 to 70 °C (suffix code 3)
  • Weight:
    0.661 lbs (0.3 kg)
  • Estimated shipping dimensions:
    3.2 x 12.5 x 13 cm
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Configuration & Programming Monitoring & Control Applications

Features:

  • Provides 16 isolated channels for resistance-based field inputs.
  • Accepts three-wire JIS Pt100 RTD or potentiometer inputs.
  • Allows RTD or potentiometer input selection independently for each channel.
The current configuration identifies an AAR145-S03 S1 RTD/POT module for a Yokogawa FIO system. The S03 suffix specifies the ISA Standard G3 and -20 to 70 °C options.

The module acquires resistance signals from temperature sensors or potentiometers and transfers measurement data to the control system for process monitoring.

Before commissioning, verify the FIO node, terminal-board and cable combination, sensor mode and channel mapping. Keep the specified IN A and IN C RTD signal-wire resistances equal.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa AAR145-S03 S1:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Yokogawa AAR145-S03 S1 RTD/POT Input Module Specs

General

  • ManufacturerYokogawa
  • ModelAAR145-S03 S1
  • ConditionNew & Unused
  • Product FamilyCENTUM FIO RTD/POT Input Modules

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Use the A, B and C input terminals according to the RTD or potentiometer connection diagram.
  • Configure the control-system channel for the field sensor assigned to that input.
  • Verify node and terminal-board compatibility before installing the module.
  • RTD input channels provide resistance-based measurements for process temperature monitoring.
  • Potentiometer channels provide resistance measurements for configured position-related signals.
  • Channel measurements are delivered to the FIO control-system application for monitoring and control.
  • Use RTD inputs where a process point is measured with a supported Pt100 sensor.
  • Use potentiometer inputs for compatible variable-resistance field devices.
  • Assign each measurement to the relevant CENTUM control and operator-display strategy.
Description
Yokogawa AAR145-S03 S1 is an isolated resistance-input module for the CENTUM field I/O architecture. It accepts three-wire RTD measurements and potentiometer signals through individually isolated input channels used for plant temperature and position-related variables.

The module converts low-level resistance changes into digital values for the control system while monitoring each assigned channel for an open-sensor condition. Isolation between channels supports installations where field signals originate from separate devices or grounding environments.

Engineering must match the RTD or potentiometer type, terminal-board arrangement, channel mapping, and lead-wire resistance limits. For three-wire RTD circuits, the A and C conductors require equal resistance so that uncompensated wiring error does not distort the measured temperature.
Alternative Names
AAR145-S03 S1 Yokogawa AAR145-S03 S1 AAR145-S03-S1 AAR145 S03 S1 AAR145S03S1 Yokogawa AAR145S03S1 Yokogawa AAR145-S03-S1 AAR145 S03-S1
Technical notes
AAR145-S03 S1 requires equal resistance in the A and C leads of each three-wire RTD circuit; verify terminal mapping and sensor wiring before energizing the channel.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many sensor points can Yokogawa AAR145-S03 S1 acquire?
Its published configuration provides 16 isolated RTD/POT input channels; verify the installed termination and system configuration before ordering.
Which RTD element is supported by Yokogawa AAR145-S03 S1?
The module specification identifies JIS Pt100 ohm RTD input. Confirm sensor wiring and the configured measurement range in the control system.
Can Yokogawa AAR145-S03 S1 accept a potentiometer input?
Yes. The potentiometer input supports 100 Ω to 10 kΩ total resistance, with span resistance at least 50% of the total.
What wiring check matters when replacing Yokogawa AAR145-S03 S1?
Yokogawa specifies a 3-wire RTD connection; keep the signal-wire resistance for IN A and IN C equal, and match terminal mapping to the installed board.
Which terminal arrangements are listed for Yokogawa AAR145-S03 S1?
The official FIO table lists KS8 with MRT/TERT and AKB335 with AER4D arrangements. Confirm the exact node and terminal-board combination for the installed system.
Which RTD or potentiometer details should accompany a Yokogawa AAR145-S03 S1 procurement request?
Include the signal type, resistance range, terminal board, channel count, complete suffix, quantity, destination, and required inspection records.