Features:
- The vertically piped NF2 configuration with local range setting uses the 1 to 100 kPa (4 to 400 inH2O) capsule, vertical piping with left-side high pressure and connection downward and 1/2 NPT female, two entries with blind plug.
- The vertically piped NF2 configuration with local range setting provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator with range-setting switch.
- The vertically piped NF2 configuration with local range setting combines 1/2 NPT female process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
EJA110E-JMS4G-717EB/NF2 is the complete ordering identity for the configuration defined by vertical -7 installation, range-setting display and NF2 approval.
It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol.
Before commissioning, verify vertical piping orientation, display switch or intrinsic-safety installation against the installed equipment and project documentation.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA110E-JMS4G-717EB/NF2:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The vertically piped NF2 configuration with local range setting measures differential pressure across a primary flow element, filter, heat exchanger or vessel connection.
- The vertically piped NF2 configuration with local range setting supports inferred flow, level or density calculations when the impulse-piping and manifold design are validated.
- The vertically piped NF2 configuration with local range setting provides differential and static-pressure information for process control, protection or condition monitoring.
- For diagnostics, self-diagnostics supervise CPU, hardware, configuration and measurement-overrange conditions during operation.
- When reviewing diagnostics, diagnostic status is available through HART 5/HART 7 protocol and must be mapped separately from the primary pressure value.
- A replacement check should verify capsule-temperature and process-alarm behavior for the selected 1 to 100 kPa (4 to 400 inH2O) span.
- Performance is based on the selected 1 to 100 kPa (4 to 400 inH2O) capsule and the calibrated range established inside -100 to 100 kPa.
- The documented response characteristic and M/H/V stability of ±0.1% of URL for 10 years and F-capsule stability of ±0.2% per year apply under the official reference conditions.
- In the documented performance context, accuracy effects from ambient temperature, static pressure and mounting position must be included in the loop uncertainty review.
- The field cable enters through 1/2 NPT female, two entries with blind plug, while the process side uses 1/2 NPT female process connectors.
- When reviewing connectivity, signal and supply share the documented two-wire loop for the selected HART 5/HART 7 protocol output configuration.
- Grounding, shielding and sealing must suit the vertical piping with left-side high pressure and connection downward arrangement and the installed conduit system.