EJA110E-JMS4G-917DB/NF2

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa EJA110E-JMS4G-917DB/NF2 is an M-capsule differential-pressure configuration with 316L SST bolting and NF2 intrinsic-safety approval for differential-pressure, flow, level or density measurement.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for EJA110E-JMS4G-917DB/NF2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EJA110E-JMS4G-917DB/NF2

  • Manufacturer:
    Yokogawa
  • Part Number:
    EJA110E-JMS4G-917DB/NF2
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    Differential Pressure Transmitter
  • Stock:
    1
  • Measurement / Function:
    differential pressure and static pressure
  • Output / Command Signal:
    4–20 mA DC with digital communication
  • Communication / Control Interface:
    HART 5/HART 7 protocol
  • Selected Span / Torque Class:
    1 to 100 kPa (4 to 400 inH2O)
  • Configurable Range / Travel:
    -100 to 100 kPa
  • Process / Pneumatic Connection:
    1/2 NPT female process connectors
  • Wetted / Service Materials:
    S-code wetted assembly with Hastelloy C-276 diaphragm
  • Bolting / Mechanical Interface:
    316L SST bolts and nuts
  • Installation Arrangement:
    Horizontal piping with left-side high pressure
  • Housing:
    Cast aluminum amplifier housing
  • Electrical Connection:
    1/2 NPT female, two entries with blind plug
  • Local Indicator:
    Digital indicator
  • Mounting Hardware:
    304 SST flat 2-inch pipe bracket
  • Ordering Options:
    The /NF2 suffix specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types.
  • Degree of Protection:
    IP66/IP67, Type 4X
  • Ambient Conditions:
    -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD
  • Process / Service Temperature:
    -40 to 120°C (-40 to 248°F)
  • Communication Load / I/O:
    a total loop-load range of 0 to 1290 Ω, with 250 to 600 Ω required for digital communication
  • Stability / Control Performance:
    M/H/V stability ±0.1% of URL for 10 years; F ±0.2% per year
  • Manufacturer Reference:
    Yokogawa GS 01C31B01-01EN
  • Tariff Code:
    9026201090
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Humidity Range Control Updates

Features:

  • The NF2-approved M-capsule configuration with stainless bolting uses the 1 to 100 kPa (4 to 400 inH2O) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries with blind plug.
  • The NF2-approved M-capsule configuration with stainless bolting provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator.
  • The NF2-approved M-capsule configuration with stainless bolting combines 1/2 NPT female process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
For EJA110E-JMS4G-917DB/NF2, the order code combines NF2 intrinsic-safety entity values and M-capsule range as one matched configuration.

It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol.

Installation approval should include a documented check of approval suffix, bolt material or pressure orientation and the connected system.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA110E-JMS4G-917DB/NF2: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • The NF2-approved M-capsule configuration with stainless bolting measures differential pressure across a primary flow element, filter, heat exchanger or vessel connection.
  • The NF2-approved M-capsule configuration with stainless bolting supports inferred flow, level or density calculations when the impulse-piping and manifold design are validated.
  • The NF2-approved M-capsule configuration with stainless bolting provides differential and static-pressure information for process control, protection or condition monitoring.
  • The transmitter family is specified for 0 to 100% relative humidity when covers and cable entries are correctly sealed.
  • Condensation control depends on maintaining the IP66/IP67, Type 4X enclosure and using an approved conduit sealing method.
  • The 1/2 NPT female, two entries with blind plug entry must prevent moisture migration into the terminal compartment during outdoor operation.
  • The documented 4–20 mA DC with digital communication output supplies the primary process variable to an analog control or safety input.
  • Damping and output characterization can be configured without changing the physical 1 to 100 kPa (4 to 400 inH2O) capsule selection.
  • Failure-current behavior must be coordinated with the receiving controller's upscale or downscale alarm strategy.
  • Back up range, damping, output mode, alarm direction and tag data before exchanging the transmitter electronics.
  • Any host update must retain support for HART 5/HART 7 protocol and the selected diagnostic variables used by the control system.
  • After restoration, compare the downloaded configuration with the physical 1 to 100 kPa (4 to 400 inH2O) capsule and 1/2 NPT female process connections.
Description
EJA110E-JMS4G-917DB/NF2 identifies the ordered EJA110E differential pressure transmitter, not a generic family item. The distinguishing configuration is NF2 intrinsic-safety entity values and M-capsule range.

It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol. The configuration is intended for differential-pressure measurement across primary elements, filters, heat exchangers or vessels when the process and installation limits are satisfied.

Successful installation depends on matching the original order-code details and field conditions. Verify approval suffix, bolt material or pressure orientation before commissioning.
Alternative Names
EJA110E-JMS4G-917DB/NF2 Yokogawa EJA110E-JMS4G-917DB/NF2 EJA110E JMS4G 917DB NF2 EJA110E-JMS4G-917DB-NF2 EJA110EJMS4G917DBNF2 Yokogawa EJA110E Differential Pressure Transmitter Yokogawa EJA110E-JMS4G-917DB/NF2 Differential Pressure Transmitter Yokogawa DPharp EJA EJA110E-JMS4G-917DB/NF2
Technical notes
Equalize and vent the manifold before zero adjustment; applying static pressure to only one side can damage the capsule or create a hazardous release.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which pressure-side hardware is supplied with EJA110E-JMS4G-917DB/NF2?
The order includes 1/2 NPT female process connectors on the differential-pressure assembly and uses 316L SST bolting with the selected wetted construction.
What host support is required to configure EJA110E-JMS4G-917DB/NF2?
Use a HART 5 or HART 7 capable host with the appropriate Yokogawa device description, while maintaining the load and power conditions specified for digital communication.
Which process measurements can be engineered around EJA110E-JMS4G-917DB/NF2?
Its differential- and static-pressure sensing can support flow, level or pressure-drop measurement when the M capsule, manifold arrangement and calibrated span suit the process.
How can procurement confirm that EJA110E-JMS4G-917DB/NF2 includes the required stainless bolting?
Request a close nameplate image and written order-code confirmation identifying the G bolting selection before the unit is allocated or shipped.
What must remain unchanged when EJA110E-JMS4G-917DB/NF2 replaces a transmitter on an approved loop?
Preserve the 1/2 NPT connectors, left-high-pressure orientation, bolting material, HART revision and /NF2 intrinsic-safety requirements unless engineering approves a redesigned loop.
What documentation resolves an EJA110E-JMS4G-917DB/NF2 manifold-fit inquiry?
Supply the manifold make and model, center distance, process drawing and installed nameplate together with Yokogawa GS 01C31B01-01EN for a connection-specific review.