PW482-51 S2 is a 220-240V AC input power supply module for Yokogawa CENTUM VP systems, featuring 230VA consumption, 1kg weight, and ISA Standard G3 option for harsh environments.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for PW482-51 S2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PW482-51 S2

  • Manufacturer:
    Yokogawa
  • Part Number:
    PW482-51 S2
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    Input Power Supply Module
  • Stock:
    2
  • Input Power Supply Voltage:
    220-240 V AC ±10%
  • Input Frequency:
    50/60 Hz ±3 Hz
  • Maximum Power Consumption:
    230 VA
  • Input/Output Interface:
    Exclusive connector
  • Weight:
    0.9 kg
  • Estimated shipping dimensions:
    5x14.8x20cm
  • Tariff Code:
    8517795000
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Firmware & Updates Configuration & Programming

Features:

  • PW482-51 S2 provides 230VA 220-240V AC power with dedicated connector for Yokogawa CENTUM VP systems.
  • Dual-redundant configuration support with two identical modules ensures continuous operation for critical control applications.
  • ISA Standard G3 option delivers corrosion resistance and -20°C to 70°C operation for harsh industrial environments.
The PW482-51 S2 is specifically engineered as a dedicated power supply module for Yokogawa's CENTUM VP distributed control system components. Unlike generic power supplies that can be used across various equipment, the PW482-51 S2 is exclusively designed for Field Control Units (FCU models AFV30D, AFV50D, AFV70D), FIO Node Units (ANB10D, ANB11D), and Optical ESB Bus Repeater Units (ANT10U). This specialization ensures that the output voltage and current characteristics are precisely matched to the power requirements of these Yokogawa components, providing reliable and stable operation.

The PW482-51 S2 supports dual-redundant power configurations, a critical feature for continuous process control applications where power supply failure cannot be tolerated. By installing two identical PW482-51 S2 modules in slots P1 and P2 of the base plate, the system can tolerate a single power supply failure without interrupting operation. If the primary module fails, the secondary module automatically continues to supply power to the FCU, FIO Node, or ESB Repeater unit. In single configuration, the PW482-51 S2 must be installed in slot P1. For redundant operation, both modules must have identical model codes to ensure proper load sharing and failover characteristics.

The PW482-51 S2 with suffix code 1 includes the ISA Standard G3 option, providing enhanced protection against corrosive atmospheres. The G3 classification per ISA S71.04 indicates the module is designed for harsh environments where airborne contaminants such as sulfur dioxide, hydrogen sulfide, chlorine, and other corrosive gases may be present. This makes the PW482-51 S2 suitable for installation in chemical plants, refineries, wastewater treatment facilities, and offshore platforms where standard electronics would rapidly deteriorate. The G3 option also extends the operating temperature range to -20°C to 70°C, allowing the PW482-51 S2 to function in unheated control rooms, outdoor enclosures, and extreme climate locations.

The PW482-51 S2 YOKOGAWA Input Power Supply Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).

YOKOGAWA PW482-51 S2 Input Power Supply Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
YOKOGAWA PW482-51 S2 Input Power Supply Module Specs

General

  • Manufacturer YOKOGAWA
  • Model PW482-51 S2
  • Condition New Original ready stock
  • Product Family PW482-10,PW482-S01,PW482-10 S2,PW482-11 S2
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Process Control Rooms: Continuous chemical distillation plants, petrochemical cracking units, oil refineries, and pharmaceutical manufacturing facilities.
  • Mission-Critical Power Generation: Main boiler controls, steam/gas turbine interlocks, and nuclear auxiliary balance of plant (BOP) machinery.
  • Mission-Critical Power Generation: Main boiler controls, steam/gas turbine interlocks, and nuclear auxiliary balance of plant (BOP) machinery.
  • No Firmware Required: Because it contains no microcode or digital operating system, it has no firmware to manage or update. There is no software tool, utility, or flashing procedure associated with this unit.
  • The S2 Style Code: The trailing S2 represents a manufacturing Style Code (Style 2). This indicates second-generation layout adjustments completed at Yokogawa’s factories (such as upgraded thermal layout or longer-lived heavy capacitors). The Style 2 module remains completely plug-compatible and backward-compatible with legacy Style 1 units.
  • Dedicated Slotting: Within a Field Control Unit (FCU) or an FIO Node Unit rack, power supply slots are hard-coded on the extreme left. They are designated as slots P1 and P2.
  • Single Layout: If redundancy is not required by site design, a solitary PW482 must be positioned exclusively in the P1 slot.
  • Dual-Redundant Layout: For mission-critical tasks, matching PW482 modules are installed into both P1 and P2 slots. Internal load-sharing circuitry balances current distribution evenly (roughly 50/50) under standard conditions.
Description
The PW482-51 S2 is a 220-240V AC input power supply module designed for Yokogawa CENTUM VP Field Control Units (FCU), FIO Node Units, and Optical ESB Bus Repeater Units. The PW482-51 S2 features an exclusive input/output connector and is designed to be installed in slots P1-P2 of compatible base plates including AFV30D, AFV50D, AFV70D, ANB10D, ANB11D, and ANT10U.

The PW482-51 S2 supports dual-redundant power configurations by installing two identical modules in slots P1 and P2. In a single configuration, the module must be installed in slot P1. The PW482-51 S2 suffix codes indicate: -5 for standard type with no explosion protection, and 1 for ISA Standard G3 option with extended temperature range of -20°C to 70°C. 

The PW482-51 S2 is a dedicated power supply module for Yokogawa's distributed control system and cannot be used as a generic power supply. The PW482-51 S2 provides exclusive power output to FCU, FIO Node, and Optical ESB Bus Repeater units only. 

For explosion protection requirements, the PW482-51 S2 standard type (-5) has no explosion protection. Users requiring explosion protection should select the -E suffix version. The PW482-51 S2 dimensions follow Yokogawa's standard form factor for CENTUM VP series components.
Alternative Names
PW482-5I S2 PW482 51 S2 PW482-10 PW482-S01 PW482-10 S2 PW482-11 S2 PW482-50 S2 PW481-10
Technical notes
The PW482-51 S2 is a 230VA power supply module for Yokogawa CENTUM VP. Input: 220-240V AC, 50/60Hz. Features ISA G3 option (-20°C to 70°C). Supports dual-redundant configuration. No explosion protection (-5). Dedicated for FCU, FIO Node, and ESB Repeater units. Install in slot P1 (single) or P1+P2 (redundant).
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What systems use PW482-51 S2?
PW482-51 S2 powers Yokogawa CENTUM VP Field Control Units (FCU), FIO Node Units, and Optical ESB Bus Repeater Units exclusively.
Can PW482-51 S2 be used redundantly?
Yes, PW482-51 S2 supports dual-redundant configuration by installing two identical modules in slots P1 and P2 for continuous operation.
What is the G3 option on PW482-51 S2?
Suffix 1 on PW482-51 S2 provides ISA Standard G3 corrosion protection and extended temperature range from -20°C to 70°C.
What is the power consumption of PW482-51 S2?
PW482-51 S2 consumes maximum 230VA at 220-240V AC, 50/60Hz input.