Features:
- The B-capsule direct-mount configuration with local range setting uses the 0.1 to 2 MPa (14.5 to 290 psi) capsule, direct-mount pressure connection and M20 female, two entries with blind plug.
- The B-capsule direct-mount configuration with local range setting provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator with range-setting switch.
- The B-capsule direct-mount configuration with local range setting combines 1/2 NPT female process connection, 316L SST process connector with Hastelloy C-276 diaphragm and 316 SST 2-inch pipe bracket.
The EJA530E-JBS4N-019EL suffix sequence selects B capsule code (0.1 to 2 MPa), M20 electrical entry and range-setting indicator within the EJA530E platform.
It converts gauge pressure into a control-system signal and supports configuration or diagnostic access through HART 5/HART 7 protocol.
Confirm M20 entry, push-button indicator or pipe bracket before accepting the unit as a mechanical, electrical or functional replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA530E-JBS4N-019EL:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The B-capsule direct-mount configuration with local range setting measures liquid, gas or steam line pressure through a direct process-mounted connection.
- The B-capsule direct-mount configuration with local range setting supports pump, compressor, vessel or header pressure monitoring in an engineered control loop.
- The B-capsule direct-mount configuration with local range setting provides a primary pressure variable and diagnostic status for process control or asset monitoring.
- The field cable enters through M20 female, two entries with blind plug, while the process side uses 1/2 NPT female process connection.
- Signal and supply share the documented two-wire loop for the selected HART 5/HART 7 protocol output configuration.
- Grounding, shielding and sealing must suit the direct-mount pressure connection arrangement and the installed conduit system.
- The assembled housing is rated IP66/IP67, Type 4X when covers, plugs and the M20 female, two entries with blind plug entry are correctly sealed.
- The rating does not extend to an incorrectly fitted process connector or an open conduit path.
- Any approval suffix, coating option or stainless housing selection must be read from the complete order code before installation.
- The transmitter family is designed to the applicable EN 61010 safety and EN 61326 EMC requirements listed by Yokogawa.
- Installed compliance depends on retaining the IP66/IP67, Type 4X enclosure, approved entries and specified process materials.
- Any hazardous-location claim must be supported by the exact option suffix and matching nameplate rather than the base family alone.