ABB 3BHB000272R0001 UFC719AE01 I/O board label
ABB 3BHB000272R0001 UFC719AE01 I/O board label
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can quote the exact 3BHB000272R0001 UFC719AE01 board and review the photographed interfaces.

3BHB000272R0001 UFC719AE01

/ 4.9
1001 reviews | Need a Specific Revision?
ABB 3BHB000272R0001 UFC719AE01 is an I/O interface board with photographed analog and digital terminal markings.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 3BHB000272R0001 UFC719AE01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3BHB000272R0001 UFC719AE01

  • Manufacturer:
    ABB
  • Part Number:
    3BHB000272R0001 UFC719AE01
  • Product Family:
    ABB Advant OCS and Advant-800xA
  • Product Type:
    ABB I/O Interface Board
  • Stock:
    1
  • ABB Product ID:
    3BHB000272R0001
  • ABB Type:
    UFC719 AE01
  • Photographed Label Reference:
    30045312 / 0004
  • Analog Channel Markings:
    AI1, AI2, AI3, AI4
  • Analog Range Legends:
    20 mA / 10 V per photographed channel
  • Other Visible Interfaces:
    Numbered digital I/O and status points
  • Board Marking:
    IFP1
  • Weight:
    0.6 kg
  • Estimated shipping dimensions:
    45 x 12.1 x 4.5 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Identity Check Visible Interfaces Installation Boundary Product Applications

Features:

  • Exact paired identity: 3BHB000272R0001 UFC719AE01 combines the product ID and UFC719 AE01 type.
  • Visible analog legends: AI1–AI4 are marked 20 mA / 10 V.
  • Conservative scope: Unprinted compatibility and hot-swap claims are removed.
The product image documents the exact identity and the visible analog, digital and status legends.

Commissioning and wiring still require the host-system documentation because a board photograph is not a full terminal specification.

The combined label and connector layout give maintenance a concrete basis for rejecting another UFC719 revision without approval.

Apter Power supports ABB 3BHB000272R0001 UFC719AE01 ABB I/O Interface Board label review, exact-revision sourcing and quotation.
ABB 3BHB000272R0001 UFC719AE01 ABB I/O Interface Board Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Primary identity: Match the 3BHB product ID and UFC719 AE01 type.
  • Build reference: Record 30045312 / 0004.
  • Analog legends: AI1–AI4 show 20 mA / 10 V markings.
  • Other terminals: Digital and status labels must be interpreted from host documentation.
  • No revision substitution: AE01 is not automatically interchangeable with another UFC719 build.
  • No inferred hot swap: Follow the documented shutdown and replacement procedure.
  • Legacy I/O service: Supports exact-board maintenance in the installed ABB system.
  • Receiving inspection: Compares labels, connector positions and terminal legends.
Description
The exact board identity is 3BHB000272R0001 UFC719AE01. Its label also carries 30045312 / 0004, providing a build-level reference for receiving and installed-base records.

On 3BHB000272R0001 UFC719AE01, analog channels AI1 through AI4 are marked 20 mA / 10 V beside numbered digital I/O and status points. Those interface legends help wiring review without becoming a complete terminal specification.

A replacement review for 3BHB000272R0001 UFC719AE01 should match the full product ID, UFC719 AE01 type, connector layout and terminal legends. Ratings, controller compatibility and hot-swap behavior are not inferred from adjacent revisions.
Alternative Names
ABB 3BHB000272R0001 UFC719AE01 3BHB000272R0001 UFC719 AE01 UFC719AE01 3BHB000272R0001
Technical notes
3BHB000272R0001 UFC719AE01 shows AI1–AI4 analog legends marked 20 mA / 10 V, but the board markings do not define every terminal function. Wiring limits, channel configuration and shutdown procedure must therefore come from the installed host documentation rather than assumptions transferred from another UFC719 revision.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
During wiring review, do the 20 mA / 10 V legends on 3BHB000272R0001 UFC719AE01 apply to every terminal?
No. They appear beside AI1 through AI4; the numbered digital and status terminals must follow the host wiring documentation.
Can maintenance install an AE02 board in place of 3BHB000272R0001 UFC719AE01?
No automatic substitution is established. Stop unless the complete product ID, revision and host documentation approve the change.
Should receiving use 30045312 / 0004 when accepting 3BHB000272R0001 UFC719AE01?
Yes. Use it as an additional build-level comparison while the complete product model remains the purchase identity.
May technicians hot-swap 3BHB000272R0001 UFC719AE01 during a short outage?
Do not assume hot-swap operation. Follow the installed-equipment shutdown and replacement procedure because the board markings do not establish that capability.