Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with TC513 3BSE006385R1

All in stock · Add one and it is quoted together with the model, one shipping cost.

ABB TC513 3BSE006385R1 Advant Fieldbus 100 Conversion Modem

TC513 3BSE006385R1

ABB TC513 3BSE006385R1 is an Advant Fieldbus 100 conversion modem that carries the same fieldbus traffic between twisted-pair and coaxial cable sections.

In Stock Ships by Thursday, November 26 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for TC513 3BSE006385R1

TC513 3BSE006385R1ABB Advant Fieldbus 100 Conversion Modem
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
ABB
Part Number
TC513 3BSE006385R1
Product Family
ABB Advant OCS and Advant-800xA
Product Type
Advant Fieldbus 100 Conversion Modem
Stock
1
Tariff Code
8517629990
Country of origin
Sweden
Place of shipment
Xiamen,Fujian,China
 

More information

Features:

  • Converts an AF100 cable section between twisted-pair and coaxial media while leaving the bus protocol unchanged.
  • Electrically isolates the two cable media and operates from a 24 V DC auxiliary supply.
  • Provides defined X1-X4 connectors for power, twisted-pair wiring, and coaxial-side network connection.
AF100 telegrams enter on one cable medium, pass through the modem electronics, and leave on the other medium without a controller-level protocol mapping step.

The modem contributes the equivalent of 150 m of cable to the AF100 bus-length calculation, so it must be included when the segment layout is checked.

A redundant AF100 installation uses one TC513 for each independent cable path, keeping the two network channels separate through the media transition.

Availability is confirmed against the requested ABB TC513 3BSE006385R1 AF100 Conversion Modem configuration at quotation.
ABB TC513 3BSE006385R1 AF100 Conversion Modem Manuals, Datasheets, Links:

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Keeping AF100 telegrams intact across two cable types

  • Twisted-pair side: The balanced copper pair carries the AF100 electrical signal into the modem through its assigned fieldbus connector.
  • Coaxial side: TC513 drives the coaxial section with the same AF100 traffic, allowing the bus to continue on a different physical medium.
  • Protocol behavior: The conversion changes the electrical medium rather than the fieldbus message format seen by connected stations.
  • Isolation: Electrical separation between media limits direct coupling of potential differences from one cable section to the other.

Placing the modem in the AF100 length calculation

  • Equivalent length: Each TC513 contributes 150 m to the permitted AF100 cable length even though the enclosure itself is compact.
  • Segment planning: Physical cable lengths and the modem equivalent are added before the network is accepted against the AF100 limit.
  • Transition point: The modem is installed where the topology changes medium; it is not a branch controller or additional bus master.
  • Termination: The cable section on each side retains the termination arrangement required for its own AF100 medium.

Separating power and fieldbus wiring at X1-X4

  • X1 and X2: The two-pole jack-screw connections provide defined low-pin-count paths for the documented supply and bus wiring.
  • X3: The four-pole jack-screw connector groups the corresponding multi-conductor AF100 connection at the enclosure boundary.
  • X4: The nine-pole D-sub connector provides the mating interface for the documented coaxial-side assembly.
  • Wiring check: Connector identity must be read from the TC513 hardware because TC513V1 uses a different connector arrangement.

Preserving two independent AF100 paths

  • Two modems: A redundant bus uses one TC513 on each cable path rather than sharing one converter between both channels.
  • Channel separation: Each modem carries only its assigned AF100 path, preserving the electrical independence of the redundant pair.
  • Matched layout: Both paths should use equivalent media transitions and length calculations so their timing conditions remain comparable.
  • Status comparison: A fault on one modem path can be isolated by comparing communication state on the two independent AF100 channels.

Description

ABB TC513 3BSE006385R1 is an Advant Fieldbus 100 conversion modem for ABB Advant control networks. It carries AF100 traffic between twisted-pair and coaxial cable sections so one fieldbus can continue across two physical media.

Inside TC513 3BSE006385R1, the AF100 telegram remains a fieldbus telegram while the electrical interface changes from one cable medium to the other. The two media are electrically isolated, preventing the conversion point from becoming a direct conductive bridge between cable sections.

The AF100 topology counts TC513 3BSE006385R1 as the equivalent of 150 m of cable. This value is combined with the real twisted-pair and coaxial lengths when the permitted bus span and termination positions are determined.

For redundant AF100 wiring, two TC513 3BSE006385R1 modems are used, with one assigned to each cable path. The X1-X4 connector set separates the 24 V DC supply and the documented fieldbus connections, and it differs from the connector arrangement of TC513V1.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Myrtle
Saudi ArabiaGE Fanuc IC693CPU364

Saudi Buyer Verifies GE IC693CPU364 On-Site

An Saudi project buyer with a China-based office visited three suppliers with an engineer after a previous purchase resulted in poor-quality goods that were not regarded as original. Following an on-site review of GE Fanuc IC693CPU364, IC693CPU372, IC693ALG391 and other stock in Xiamen, the customer selected IC693CPU364, placed an order and planned to test the module first.

3GE models reviewed
Trial OrderTest before wider purchase
“ Seeing the actual GE modules and stock in person gave us confidence to place our first test order. — Hassan ”
Myrtle · Saudi Arabia · October 2026
Read the full case study
Yuki
USA11 Emerson DeltaV models

11 Emerson DeltaV Models Secured and Inspected for an American Natural Gas Project

See how Apter Power secured 11 new and unused Emerson DeltaV models, supported independent powered inspection and delivered the order for an American natural gas project.

11DeltaV models secured
6 daysFull order prepared
“ Apter secured all our DeltaV models and supported independent inspection before we paid the balance. — Mohanad ”
Yuki · USA · May 2026
Read the full case study
Leonia
IndonesiaBently Nevada 3500/22M 288055-01

On-Site Verification for an Indonesian Power Plant

After a previous suspected-counterfeit purchase, an Indonesian power-plant customer used a 50/50 payment plan, visited Apter Power to inspect two Bently Nevada 3500/22M 288055-01 modules, requested COO documentation and approved next-day hotel delivery.

100%Modules inspected on site
50/50Deposit / balance after inspection
“ They are very professional and supply quality products. I have purchased Bently Nevada products from them and had a very good experience. — Tri ”
Leonia · Indonesia · May 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why must ABB TC513 3BSE006385R1 be included in the AF100 length calculation?

ABB TC513 3BSE006385R1 represents 150 m of bus cable electrically, so omitting it can put the combined AF100 span beyond the permitted limit.

Can one ABB TC513 3BSE006385R1 handle both channels of a redundant AF100 bus?

No. A redundant AF100 layout uses two ABB TC513 3BSE006385R1 modems so each cable path remains independent.

What should be checked before connecting field wiring to ABB TC513 3BSE006385R1?

Read the X1-X4 connector identities on ABB TC513 3BSE006385R1 and follow the TC513 drawing, because TC513V1 uses a different connector arrangement.

Does ABB TC513 3BSE006385R1 translate AF100 into another protocol?

ABB TC513 3BSE006385R1 changes the cable medium between twisted pair and coaxial while the AF100 telegram format remains unchanged.

How can a media-side fault be isolated around ABB TC513 3BSE006385R1?

Check AF100 communication on each side of ABB TC513 3BSE006385R1, then verify the relevant termination, connector, and 24 V DC supply path.

Why is ABB TC513 3BSE006385R1 not an automatic substitute for TC513V1?

ABB TC513 3BSE006385R1 and TC513V1 differ in connector arrangement, so the exact cable interfaces must be compared before either unit is selected.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

EI803F 3BDH000017R1
The ABB EI803F 3BDH000017R1 Ethernet module uses a 10BaseT twisted-pair interface to enable stable, deterministic Ethernet communication in ABB Freelance and Advant OCS controller series, such as the AC 800F system.
In stock
APBU-44C
The APBU-44C provides reliable parallel connection and real-time data logging for ACS800 multidrive modules in a compact DIN rail-mountable form.
PU515A 3BSE032401R1
The PU515A 3BSE032401R1 Real Time Accelerator Module is a high-performance component designed to enhance system processing capabilities.
DSTX170 57160001-ADK
The ABB DSTX170 57160001-ADK Connection Unit is a four-channel high-speed pulse counter board designed for precise motor position, speed, and frequency measurement in industrial automation applications.
PM581-ETH
The ABB PM581-ETH 1SAP140100R0170 CPU delivers robust 256 kB program memory and Ethernet connectivity for reliable industrial control in PLC applications.
TB811 3BSE008568R1
The ABB TB811 (part number 3BSE008568R1) is a high-performance Modulebus Optical Port specifically designed for seamless integration with ABB's industrial automation systems, including the Advant Master, AC800M, and 800xA platforms.
In stock
DI811 3BSE008552R1
ABB DI811 3BSE008552R1 is a 16-channel S800 digital input module for 48 V DC current-sinking field signals.
In stock
TU830V1 3BSE013234R1
ABB TU830V1 3BSE013234R1 is an extended 16-channel terminal-block MTU for selected S800 I/O modules.
In stock
TK856
The ABB TK856 is a 1-meter prefabricated RCU control link cable designed for reliable communication between the PM891 controller and ABB AC 800M or 800xA systems.
ECPSR 086370-001
The ABB ECPSR 086370-001 is a printed wire assembly (PWA) control board engineered for precision power regulation and component management within ABB’s heritage Quality Control Systems (QCS) and industrial automation networks.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat