ACS550-01-038A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS550-01-038A-4 is an 18.5 kW, 38 A R3 drive whose dependable operation depends on thermal, cable, and reduced-speed motor planning.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS550-01-038A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS550-01-038A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS550-01-038A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS550 General Purpose Drive
  • Stock:
    1
  • Supply Voltage:
    3-phase 380 ... 480 V AC
  • Input Frequency:
    48 ... 63 Hz
  • Normal Output Current:
    38 A
  • Normal Output Power:
    18.5 kW
  • Heavy-duty Output Current:
    31 A
  • Heavy-duty Output Power:
    15 kW
  • Frame Size:
    R3
  • Degree of Protection:
    IP21
  • Mounting:
    Wall-mounted
  • Motor Control:
    Scalar and sensorless vector control
  • Embedded Communication:
    Modbus RTU
  • Analog Inputs:
    2
  • Analog Outputs:
    2
  • Digital Inputs:
    6
  • Relay Outputs:
    3
  • Weight:
    16 kg
  • Estimated shipping dimensions:
    20.3 x 49 x 23.1 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Thermal Motor Cable Startup

Features:

  • 38 A R3 rating with separate normal and heavy-duty points
  • Thermal planning for reduced-speed and elevated-environment service
  • Motor-cable and serial-network checks that influence reliable operation
ACS550-01-038A-4 is best distinguished by the thermal and motor-system decisions surrounding its 38 A R3 duty.

Long cables, older motor insulation, reduced-speed loading, switching frequency, altitude, and enclosure airflow can change the accessory or derating review without changing the drive type code.

A useful maintenance baseline records cabinet temperature, loaded current, fan and heat-sink condition, serial settings, motor-cable details, and the circumstances surrounding any recurring trip.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS550-01-038A-4 ACS550 Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS550-01-038A-4 ACS550 General Purpose Drive Specs

General

  • ManufacturerABB
  • ModelACS550-01-038A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS550 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Drive and cabinet heat management

  • Ambient: Compare the site temperature with the ABB rating and derating instructions.
  • Altitude: Apply the documented current reduction when the installation elevation requires it.
  • Airflow: Keep the R3 heat-sink and fan path clear of recirculation and contamination.
  • Monitoring: Record current, temperature, fan condition, and cabinet air during loaded tests.

Output-circuit engineering

  • Length: Check the installed cable length against ABB guidance and selected switching frequency.
  • Insulation: Confirm motor winding insulation and any required output filtering.
  • Shielding: Terminate the motor-cable shield and PE conductors by the approved method.
  • Routing: Separate the output circuit from signals and communication cabling.

Controlled 18.5 kW startup

  • Motor data: Enter nameplate data and verify limits before coupling normal process load.
  • Rotation: Check direction under controlled conditions with the machine made safe.
  • Controls: Test references, interlocks, local/remote selection, and serial commands.
  • Baseline: Archive parameters and representative operating values for future diagnostics.
Description
Thermal planning becomes more prominent at the ACS550-01-038A-4 duty point. ABB rates this R3 IP21 configuration at 18.5 kW and 38 A for normal use, with a documented heavy-duty point for applications that impose a different overload cycle.

A motor operated by ACS550-01-038A-4 may need special review when it runs slowly for long periods or uses a long cable. Motor self-cooling, insulation, switching effects, cable capacitance, environmental derating, and the possible need for an ABB-approved output solution belong in that assessment.

Reliable service from ACS550-01-038A-4 also depends on clean R3 airflow and a stable serial network. Maintenance should relate fan and heat-sink condition to loaded current and ambient data, while communication troubleshooting should preserve topology, termination, grounding, address, timeout, and command-source evidence.
Alternative Names
ACS550 01 038A 4 ACS55001038A4 ABB ACS550-01-038A-4 ABB ACS550 01 038A 4 ACS550 38 A 18.5 kW drive ABB ACS550 18.5 kW general purpose drive
Technical notes
For ACS550-01-038A-4, check the 38 A motor duty together with ambient temperature, altitude, switching frequency, and R3 cooling because these conditions can require derating. Verify feeder protection, conductor and PE terminations, motor-cable length, braking energy, analog-signal integrity, embedded Modbus timeout behavior, and safe access to the fan and terminals.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
At elevated temperature or altitude, how should ACS550-01-038A-4 be derated?
Use the ABB derating instructions when site temperature or elevation exceeds the base rating conditions; also include switching frequency, enclosure airflow, filter condition, and neighboring heat sources.
Which motor-cable conditions justify reviewing an output filter for ACS550-01-038A-4?
Evaluate motor insulation, cable length and capacitance, switching frequency, motor age, bearing-current risk, site EMC requirements, and ABB guidance before selecting any du/dt or other output accessory.
Why can a motor supplied by ACS550-01-038A-4 overheat at reduced speed?
Check load torque, motor self-cooling, minimum speed, current, switching frequency, motor data, mechanical drag, voltage and phase conditions, cable effects, and whether an independently powered fan is required.
When ACS550-01-038A-4 loses serial communication intermittently, what should be inspected?
Inspect network topology, termination, shielding, grounding, unique address, baud and parity, master polling, timeout settings, cable condition, electrical noise, and command-source transitions.
How should cooling maintenance intervals be set for ACS550-01-038A-4?
Set inspection intervals from contamination and duty, then check fan operation, heat-sink cleanliness, filter restriction, cabinet temperature, clearances, recirculation, alarm history, and loaded operating data.
A replacement request for ACS550-01-038A-4 needs which operating records?
Provide the full type code, motor and process duty, supply, R3 mounting and enclosure, cable length, protection, braking, I/O and network use, environmental conditions, quantity, destination, and schedule.