Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power strengthens sourcing confidence through exact-code review, documented condition checks, official references, and attentive quotation support.

3HAC058993-004

/ 4.9
1001 reviews | Need a Specific Revision?
ABB 3HAC058993-004 is the graphite-white rotational AC motor-with-pinion assembly documented for IRB 6660 axis 1.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 3HAC058993-004
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3HAC058993-004

  • Manufacturer:
    ABB
  • Part Number:
    3HAC058993-004
  • Product Family:
    ABB Robots
  • Product Type:
    IRB 6660 Axis-1 Motor with Pinion
  • Stock:
    1
  • Axis position:
    1
  • Motor type:
    Rotational AC motor
  • Mechanical scope:
    Motor with pinion
  • Color:
    Graphite White
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Order Boundary Interface Scope Document Route Product Applications

Features:

  • Graphite-white variant: the -004 suffix identifies this IRB 6660 axis-1 entry
  • Motor with pinion: the mechanical interface is part of the ordered assembly
  • Controlled refit: ABB defines sealing, cable, fastening, calibration, and first-run steps
3HAC058993-004 is the graphite-white IRB 6660 axis-1 motor order entry, with its pinion included.

The ABB procedure coordinates sealing, brake release, connector restoration, fastening, calibration, and the controlled first test run.

The -004 suffix, not paint alone, keeps this configuration separate from the orange -003 spare.
Apter Power can assess 3HAC058993-004 label evidence, pinion condition, official procedure scope, and quotation requirements.
ABB 3HAC058993-004 IRB 6660 Axis-1 Motor with Pinion Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Robot: ABB records the motor for IRB 6660.
  • Axis: the documented position is axis 1.
  • Assembly: the spare includes motor and pinion.
  • Variant: the -004 suffix identifies graphite white.
  • Electrical path: marked connectors restore the motor circuits.
  • Motor interface: ABB specifies a new O-ring.
  • Cover interfaces: motor and cable-gland gaskets are inspected before closure.
  • Attachment: four M10x40 screws secure the motor.
  • Spare source: 3HAC049112-001 establishes the -004 order row.
  • Repair source: 3HAC028197-001 contains removal and refit steps.
  • Reference source: the ABB manual controls calibration.
  • Release source: the same manual defines the first test run.
  • Graphite-white IRB 6660 repair: restore the documented axis-1 motor configuration.
  • Base-axis service preparation: plan the brake-release, sealing, fastening, and calibration steps as one job.
  • Suffix-controlled procurement: prevent the -003 and -004 color records from being merged.
Description
3HAC058993-004 is the graphite-white rotational AC motor with pinion documented by ABB for axis 1 of the IRB 6660. The complete -004 suffix is the authoritative configuration identifier for purchasing and receiving.

Within ABB's base-axis procedure, 3HAC058993-004 is reassembled with a new O-ring, marked cable reconnection, sealed covers, controlled brake release, and specified fasteners before calibration and a first test run.

A purchasing decision for 3HAC058993-004 should combine the complete manufacturer label with the IRB 6660 axis-1 record and the required condition. Graphite-white appearance supports, but cannot replace, traceable order-code evidence.
Alternative Names
3HAC058993004 IRB 6660 axis 1 white motor ABB graphite white base-axis motor IRB6660 motor and pinion white
Technical notes
ABB requires 3HAC058993-004 to be lifted straight out with paired removal screws and lowered without forcing the pinion into the gearbox. A damaged pinion must be replaced. This mechanical stop condition is more important than paint appearance; reject or quarantine any assembly showing pinion damage before the IRB 6660 is reassembled.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should receiving handle a graphite-white motor whose label does not confirm 3HAC058993-004?
Quarantine it until the full ABB identity and axis assignment are traceable. Finish supports the check, but repainting can make appearance unreliable.
What should happen if a cover gasket is torn during work on 3HAC058993-004?
Replace it before closure and verify the cover seals correctly. Continuing with damaged sealing material leaves the ABB reassembly requirement incomplete.
Why should a controlled 24 VDC source be prepared for 3HAC058993-004 installation?
ABB uses 24 VDC brake release while the pinion is engaged. Without that source, the team should not improvise force at the interface.
Can an unverified torque wrench close the motor fasteners on 3HAC058993-004?
It should not be accepted for the documented 50 Nm step. Use controlled tooling so the installation record proves the ABB requirement.
What if the first test run is proposed before calibration of 3HAC058993-004?
Delay the run. ABB places recalibration before the controlled test sequence, so energizing early bypasses required reference restoration and documented closeout.
Which facts make a 3HAC058993-004 RFQ specific rather than generic?
Provide both labels, axis-1 confirmation, the graphite-white -004 requirement, requested condition, and outage date so suppliers can verify the exact service object.