    Apter Power supports quotation, documentation, and controller-configuration guidance for this dust-collector cleaning board.

AMETEK DNC-T2010-BDC MPC-T2010-021

/ 4.9
1001 reviews | Need a Specific Revision?
AMETEK DNC-T2010-BDC MPC-T2010-021 is a dust-collector timer control board with pressure-switch input, ten solid-state outputs, display controls, and adjustable cleaning timing.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for AMETEK DNC-T2010-BDC MPC-T2010-021
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for AMETEK DNC-T2010-BDC MPC-T2010-021

  • Manufacturer:
    AMETEK
  • Part Number:
    AMETEK DNC-T2010-BDC MPC-T2010-021
  • Product Family:
    AMETEK
  • Product Type:
    DNC-T2010-BDC Dust Collector Timer Control Board
  • Stock:
    1
  • Controller supply:
    12–24 VDC, ±20%
  • Controller power:
    3.5 W maximum, excluding loads
  • Outputs:
    10 solid-state outputs
  • Maximum output load:
    3 A resistive per output
  • On-time range:
    50 ms to 600 s
  • Off-time range:
    1 to 999 s
  • Operating temperature:
    -40 to 66 °C
  • Weight:
    0.18 kg
  • Estimated shipping dimensions:
    17.1x12x3.5cm
  • Tariff Code:
    8537109090
  • Country of origin:
    Mexico
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Configuration Monitoring & Control Installation & Integration Applications

Features:

  • Cleaning sequence: Drives ten outputs in a configurable pulse-cleaning cycle.
  • Demand input: Accepts pressure-switch control for on-demand cleaning.
  • Local controls: Provides display selection for timing and sequence settings.
The controller code and PCB code identify the same photographed assembly at different levels.

Supply, load, and pressure-switch wiring should be checked before any timing changes are made.

An enclosure remains necessary because the product is an open electronic assembly.

Apter Power supports AMETEK DNC-T2010-BDC MPC-T2010-021 quotations, official documents, and cleaning-control review.
AMETEK DNC-T2010-BDC MPC-T2010-021 Dust Collector Timer Control Board Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • On time: Set pulse duration for the installed valve and filter-cleaning design.
  • Off time: Allow the engineered interval between successive cleaning outputs.
  • Last output: Keep the sequence endpoint aligned with the number of connected loads.
  • Demand mode: Confirm how the pressure switch starts or stops cleaning.
  • Load check: Measure connected current and inspect each field conductor before startup.
  • Common path: Confirm the shared return and terminal arrangement from the wiring drawing.
  • Channel test: Exercise outputs individually under the approved service procedure.
  • Supply: Verify DC polarity, fuse, and available power before connecting loads.
  • Settings: Capture existing display values before making any adjustment.
  • Valve response: Observe one cleaning step at a time and check the intended load operates.
  • Enclosure: Restore protection against dust, moisture, heat, and accidental contact.
  • Baghouse cleaning: Sequences pulse valves used to clean industrial filter media.
  • Demand cleaning: Uses a pressure-switch input where cleaning follows process conditions.
  • Timed output control: Applies local on-time, off-time, and last-output settings to connected cleaning loads.
Description
Controlling timed filter-cleaning sequences, AMETEK DNC-T2010-BDC MPC-T2010-021 combines the DNC controller designation with the MPC-T2010-021 PCB code visible on the same assembly. Its display and front controls support on-time, off-time, last-output, and cleaning settings.

The ten solid-state outputs on AMETEK DNC-T2010-BDC MPC-T2010-021 are intended for sequential load control, while the pressure-switch input can govern cleaning demand. Supply voltage, output load, wiring common, fuse, and pressure-switch logic should be verified before energisation.

Apter Power can provide AMETEK DNC-T2010-BDC MPC-T2010-021 quotations, official technical documentation, and timer-application guidance. The full controller and PCB markings help distinguish this board from earlier timer assemblies and unrelated T2010 products.
Alternative Names
DNC-T2010-BDC MPC-T2010-021 DNC T2010 BDC MPC T2010 021 DNC-T2010-BDC MPC-T2010-021 AMETEK T2010-BDC T2010-BDC Timer Board MPC-T2010-021 REV B
Technical notes
For AMETEK DNC-T2010-BDC MPC-T2010-021, verify DC supply polarity, fuse rating, output common, pressure-switch logic, connected load current, and saved timing values before startup. Isolate power before field wiring changes. Commission one cleaning step at a time and confirm valve response without exceeding the documented resistive-load limit.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should output loading be checked on AMETEK DNC-T2010-BDC MPC-T2010-021?
Measure each connected load and confirm its switching current and wiring comply with the approved controller documentation before energising outputs.
The cleaning sequence on AMETEK DNC-T2010-BDC MPC-T2010-021 does not start; what should be checked?
Check DC supply, fuse, pressure-switch state, configured mode, display setting, output common, and the first connected load.
One output of AMETEK DNC-T2010-BDC MPC-T2010-021 remains inactive while later outputs operate; what is a useful test?
Disconnect power, inspect that channel wiring and load, then use the authorised service procedure to compare command and output behaviour.
Can the timing values on AMETEK DNC-T2010-BDC MPC-T2010-021 be copied from another dust collector?
Only if the process, valves, manifold, filter design, and approved operating procedure are the same; otherwise retain the site-engineered settings.
What environmental protection is needed for AMETEK DNC-T2010-BDC MPC-T2010-021?
Install the board in the documented protective enclosure and keep conductive dust, moisture, and excessive heat away from the open electronics.
What should accompany an enquiry for AMETEK DNC-T2010-BDC MPC-T2010-021?
Provide both board codes, supply voltage, load details, pressure-switch use, timing settings, quantity, destination, and required documents.