Features:
- A female DB9 converts the host RS-232 signal to two-wire RS-485 or four-wire RS-422.
- The field interface is separated by 3,000 VDC isolation and includes RS-485 surge protection.
- Internal switches select serial framing and line mode, while LEDs distinguish power and data direction.
Advantech ADAM-4520 connects a conventional RS-232 host to a longer multidrop RS-485 or point-to-point RS-422 field link.
Automatic RS-485 direction control handles transmit and receive changes without an addressable command from the host.
Power, framing, baud rate, and two-wire/four-wire mode are established at the converter before the field network is energized.
The Advantech ADAM-4520 Isolated RS-232 to RS-422/485 Converter is covered by the staged manufacturer documentation; Apter Power can assist with quotations, manuals, and exact-model matching.
Advantech ADAM-4520 Isolated RS-232 to RS-422/485 Converter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Host-to-Field Signal Flow
- Host connector: The female DB9 receives the RS-232 transmit, receive, and control signals from the host.
- Two-wire path: In RS-485 mode, one differential pair alternates between transmitted and received data.
- Four-wire path: In RS-422 mode, separate transmit and receive pairs carry data simultaneously.
- Direction handling: Automatic data-flow control changes the RS-485 line direction as serial traffic passes through the converter.
Electrical Separation
- Isolation barrier: The RS-232 side and field interface are separated by a 3,000 VDC isolation rating.
- Field-line protection: Surge protection is applied to the RS-485 data line.
- Power protection: The 10–30 VDC input includes reverse-polarity protection.
- Status boundary: Power and data-flow LEDs show whether the issue is at the supply or in one direction of the serial path.
Internal Serial Configuration
- Data framing: SW1 selects 9-, 10-, 11-, or 12-bit serial frames.
- Rate selection: SW2 selects 1,200 bps through 115.2 kbps, with 9,600 bps as the factory setting.
- Default frame: The factory data format is 10 bits: one start bit, eight data bits, no parity, and one stop bit.
- Line mode: RTS control and four-wire RS-422 operation are switchable alternatives to automatic two-wire RS-485.
Terminal and Supply Checks
- Field conductors: The plug-in terminal accepts #14–22 AWG conductors for the RS-422/485 pair or pairs.
- Supply range: An unregulated 10–30 VDC source powers the converter through the protected input.
- Host connection: The RS-232 cable lands on the female DB9 rather than sharing the field terminal.
- Network consistency: Every device on the serial path must use the selected baud rate and compatible frame format.