- Line-side conversion for a Kinetix 5700 shared DC-bus architecture
- 55 mm mechanical format uses the documented shared-bus connector system
- Separate mains and 24 V control-power connections support coordinated system startup
Allen-Bradley 2198-P031 supplies the common DC bus for a correctly sized Kinetix 5700 system rather than operating as a motor-axis inverter.
The selected contactor, reactor, filter, branch protection, and shared-bus hardware must match the upstream supply and the complete connected drive lineup.
Confirm hardware Series, controller firmware, total bus capacitance, regenerative energy, cable routing, grounding, and enclosure cooling before commissioning.
Availability, condition, price, and shipping time for 2198-P031 are confirmed during quotation.
Allen-Bradley 2198-P031 Kinetix 5700 DC Bus Supply Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- LPJ-15SP is listed for the documented branch-circuit arrangement
- The short-circuit rating is 200,000 A rms symmetrical under the documented conditions
- Upstream protection and disconnect hardware must meet the installation standard
- 100-C16EJ10 is the documented contactor selection for the input arrangement
- 1321-3R12-B is the documented line-reactor selection
- 2198-BARCON-55DCAC100 supports the applicable 55 mm shared-bus connection
- Published power loss at 100% rated output is 113 W
- Internal capacitance is 585 µF and capacitive energy absorption is 129 J
- Enclosure airflow and heat dissipation must be sized for the complete drive lineup
- Shared DC-bus Kinetix 5700 systems using a 240 V three-phase supply
- Shared DC-bus Kinetix 5700 systems using a 480 V three-phase supply
- Multi-axis systems whose total load fits the documented supply and bus limits