Rockwell Automation 80190-780-01-R is a PowerFlex 7000 HMI interface board linking the drive processor to Ethernet, diagnostic, SD-card, and internal display connections.
In Stock
Ships by Tuesday, November 3
Fast Shipping Available
Get a quick price for 80190-780-01-R
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 80190-780-01-R

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    80190-780-01-R
  • Product Family:
    PowerFlex
  • Product Type:
    Rockwell Automation 80190-780-01-R PowerFlex 7000 HMI Interface Board
  • Stock:
    1
  • Board Assembly:
    HMI Interface Board
  • Assembly Elements:
    PFNI base board; NetBurner processor card
  • Diagnostic Connection:
    Port 0 via J3 or USB
  • Ethernet Interface:
    100 Mbps full-duplex
  • Removable Storage:
    SD card
  • Switch Default:
    SW2 positions Off
  • Processor Connection:
    DPM Drive Processor Module
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications HMI Connections Replacement Workflow Product Applications

Features:

  • HMI interface assembly: combines the PFNI base board and NetBurner processor card.
  • Service connectivity: provides diagnostic, Ethernet, SD-card, and internal display connections.
  • Replacement control: the existing HMI SD card is transferred to the new board.
Rockwell Automation 80190-780-01-R is documented as the PowerFlex 7000 HMI interface board assembly connecting the HMI subsystem with the drive processor module.

The board provides Port 0 diagnostics through J3 or USB, 100 Mbps full-duplex Ethernet, internal display-module connectivity, and removable SD-card storage.

During Rockwell Automation 80190-780-01-R replacement, preserve cable positions, move the existing SD card, and keep all SW2 positions at their documented Off defaults unless the applicable service procedure requires a change.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
Rockwell Automation 80190-780-01-R Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Rockwell Automation 80190-780-01-R PowerFlex 7000 HMI Interface Board Specs

General

  • ManufacturerRockwell Automation / Allen-Bradley
  • Model80190-780-01-R
  • ConditionNew Original ready stock
  • Product FamilyPowerFlex 7000
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

HMI connection map

  • Drive processor: connect the HMI interface board to the DPM as documented.
  • Diagnostics: use Port 0 through J3 or USB for the documented service path.
  • Display link: retain the internal display-module connection and cable orientation.
  • Network link: the board supports 100 Mbps full-duplex Ethernet.

Replacement workflow

  • Record first: photograph every 80190-780-01-R connection and the complete label.
  • Transfer storage: move the existing HMI SD card to the replacement board.
  • Retain defaults: leave all SW2 positions Off unless the service procedure states otherwise.
  • Verify restoration: check the documented HMI, DPM, display, diagnostic, and Ethernet paths after service.

Product applications

  • PowerFlex 7000 HMI: 80190-780-01-R serves the documented drive human-machine interface subsystem.
  • Drive-processor communication: the assembly links HMI functions with the DPM.
  • Maintenance diagnostics: Port 0 supports the documented diagnostic-access path.
  • Interface services: Ethernet, SD-card, and internal display connections support the HMI architecture.
Description
Rockwell Automation 80190-780-01-R is the PowerFlex 7000 HMI interface board assembly documented by Rockwell Automation. The module combines a PFNI base board with a NetBurner processor card and connects the HMI subsystem to the drive processor module.

For service and diagnostics, Rockwell Automation 80190-780-01-R provides Port 0 through J3 or USB, an internal display-module connection, 100 Mbps full-duplex Ethernet, and an SD-card interface used by the documented HMI architecture.

When replacing Rockwell Automation 80190-780-01-R, transfer the existing SD card to the new HMI board as directed by Rockwell Automation. Record the DPM, display, Ethernet, USB, and power connections, and leave all SW2 positions at their documented Off defaults unless an applicable service procedure states otherwise.
Alternative Names
80190 780 01 R 8019078001R AB 80190-780-01-R Rockwell 80190-780-01-R 80190-780-01
Technical notes
Before energizing Rockwell Automation 80190-780-01-R, transfer the existing HMI SD card to the replacement board, document the DPM, internal display, Ethernet, USB, and power connections, and retain all SW2 positions at their documented Off defaults unless the applicable Rockwell service procedure directs otherwise.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What role does 80190-780-01-R perform in a PowerFlex 7000 drive?
Rockwell Automation documents 80190-780-01-R as the HMI interface board assembly that connects the HMI subsystem with the drive processor module.
Which board elements make up 80190-780-01-R?
The documented 80190-780-01-R assembly combines a PFNI base board with a NetBurner processor card.
How can a technician access diagnostics on 80190-780-01-R?
For 80190-780-01-R, Rockwell Automation identifies Port 0 access through the J3 connection or USB for diagnostic use.
What Ethernet behavior is documented for 80190-780-01-R?
The 80190-780-01-R HMI interface board is documented with a 100 Mbps full-duplex Ethernet connection; project-specific addressing must follow the installed drive records.
What must be moved when replacing 80190-780-01-R?
Rockwell Automation directs technicians to transfer the existing HMI SD card to the replacement 80190-780-01-R board so the documented HMI storage is retained.
What is the default SW2 position for 80190-780-01-R?
All SW2 positions on 80190-780-01-R are documented as Off by default. Do not change them without the applicable Rockwell Automation service procedure.
What should be recorded before disconnecting 80190-780-01-R?
Before removing 80190-780-01-R, record the DPM, internal display, Ethernet, USB, and power connections, the SD-card location, and the complete board label.