Features:
- 5 kW rated output with 11 A continuous and 22 A peak output current
- Standard analog command interface for the current unsuffixed catalog configuration
- Eight optically isolated digital inputs and four optically isolated digital outputs
The catalog number identifies the standard analog-command member of the Ultra 3000 family rather than separately suffixed Sercos, DeviceNet, or indexing configurations.
Documented connections include CN1 user I/O, CN2 motor feedback, CN3 serial communication, and screw-terminal power and shunt interfaces.
Before ordering Allen-Bradley 2098-DSD-HV050, confirm the complete order code, documented configuration, and connection requirements for the installed system.
Allen-Bradley 2098-DSD-HV050 Datasheet Manuals, Datasheets, Drivers, Link
Documentation Note: This document is provided for technical reference. Please confirm the applicable product configuration and document edition before ordering.
- The standard catalog configuration uses an analog command interface and can operate as a standalone drive commissioned with Rockwell Automation UltraWARE software.
- A Logix controller can command the drive through a 1756-M02AE analog module when the documented integration architecture and wiring are followed.
- For 2098-DSD-HV050, Rockwell lists the 2090-UXLF-HV323 AC line filter; confirm motor-cable length, site supply, enclosure layout, and EMC design before selecting installation accessories.
- CN1 is a 44-pin high-density female D-sub connector for user input and output signals, while CN2 is a 15-pin motor-feedback connector.
- CN3 provides a 9-pin female D-sub serial port supporting RS-232, RS-422, and RS-485 communication at documented rates from 1200 to 38,400 bps.
- This catalog number is the analog-interface configuration; Sercos, DeviceNet, and indexing functions belong to separately suffixed Ultra 3000 catalog numbers.
- The drive is rated for 0 to 55 °C ambient operation and -40 to 70 °C storage, with 5 to 95% noncondensing relative humidity.
- Operation is specified to 1500 m altitude without derating; above that level, Rockwell specifies 3% derating for each additional 300 m.
- Mechanical ratings are 2.5 g peak vibration from 5 to 2000 Hz and 15 g shock using an 11 ms half-sine pulse.
- Use 2098-DSD-HV050 for positioning, velocity, or torque-control machine axes within its published 230-480 V AC three-phase and 11 A/22 A continuous-to-peak output ratings.
- Apply it to rotary servo applications using motor combinations explicitly listed for this catalog number in Rockwell Automation Ultra3000 system-design tables.