Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

X67AI1223

/ 4.9
1001 reviews | Need a Specific Revision?
B&R X67AI1223 is an IP67 X67 analog input module with four differential ±10 V channels and 12-bit conversion for the X67 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X67AI1223
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X67AI1223

  • Manufacturer:
    B&R
  • Part Number:
    X67AI1223
  • Product Family:
    B&R X67 System
  • Product Type:
    4-channel ±10 V Analog Input Module
  • Stock:
    1
  • Analog inputs:
    4 differential voltage channels
  • Input range:
    ±10 V
  • Resolution:
    12-bit
  • Conversion time:
    400 µs for all inputs
  • Input filter:
    1 kHz, 40 dB
  • Input resistance:
    20 MΩ
  • Maximum input voltage:
    ±30 V
  • Common-mode range:
    ±11 V
  • Gain error:
    0.1%
  • Offset error:
    0.05%
  • Crosstalk:
    < -70 dB
  • Nonlinearity:
    <0.1%
  • Sensor supply:
    0.5 A total
  • Internal I/O / X2X power:
    3 W / 0.75 W
  • Degree of protection:
    IP67
  • Operating temperature:
    -25 to 60 °C
  • Storage / transport temperature:
    -40 to 85 °C
  • Dimensions:
    5.3 × 8.5 × 4.2 cm
  • Input connectors:
    4 × M12, A-coded
  • Weight:
    0.2 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Wiring Signal Quality Protection Application
  • Measures four differential ±10 V analog signals
  • Updates all channels in 400 microseconds
  • Provides IP67 voltage acquisition near machine sensors and drives

X67AI1223 is a B&R 4-channel ±10 v analog input module designed for the X67 System.

The module acquires distributed voltage feedback and sensor signals close to drives, actuators and machine mechanisms.

Before installation or replacement, verify the complete material number, the ±10 V differential signal, common-mode range, source impedance, grounding and shielding, M12 A-coded input pinout, 400 µs update, sensor-power load, X2X mapping and IP67 sealing.

Availability, condition, price, and shipping time for X67AI1223 are confirmed during quotation.

B&R X67AI1223 4-channel ±10 V Analog Input Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Each channel measures the voltage difference between its two input conductors
  • Common-mode voltage must remain within ±11 volts
  • Shield and reference practices should prevent ground-loop current
  • The input filter is specified at 1 kHz and 40 dB
  • Cable routing should separate analog pairs from switching power conductors
  • Project scaling and raw-value limits must match the connected device
  • The documented maximum input is ±30 volts
  • Overvoltage should be removed before reconnecting the sensor
  • Connector seals and unused-port caps maintain IP67 protection
  • Distributed ±10 V drive or actuator position feedback
  • Machine-mounted voltage sensor acquisition
  • Fast four-channel analog measurement outside the control cabinet
Description
X67AI1223 is a B&R 4-channel ±10 v analog input module for the X67 System.

It converts all four channels in 400 µs, includes a 1 kHz input filter and accepts common-mode voltage within ±11 V.

Before installation or replacement, confirm the complete material number, the ±10 V differential signal, common-mode range, source impedance, grounding and shielding, M8 pinout, 400 µs update, sensor-power load, X2X mapping and IP67 sealing.
Alternative Names
X67AI1223 X67 AI1223 B&R X67AI1223 B&R X67 AI1223 BR X67AI1223 B&R X67 System X67AI1223 X67 System X67AI1223
Technical notes
X67AI1223 measures differential ±10 V signals. Verify common-mode voltage, source grounding, shielding, M12 A-coded input pinout, sensor-power load and project scaling; do not apply signals beyond the documented input limits.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can B&R X67AI1223 read 0 to 10 V sensors?
Yes, if the signal is wired within the ±10 V differential range and project scaling, reference and common-mode voltage are configured correctly.
Why does B&R X67AI1223 show a constant offset?
Check sensor zero, differential polarity, common reference, ground loops, shield termination, connector resistance, project scaling and the source device calibration.
Can the four B&R X67AI1223 channels have different ground references?
They are differential, but every channel must stay within the specified common-mode range; verify isolation and grounding of the connected equipment.
How quickly does B&R X67AI1223 update the four inputs?
All four inputs are converted in 400 µs; total control response also includes filtering, X2X cycle and controller task time.
What should be checked after an overvoltage on B&R X67AI1223?
Remove field power, correct the source, inspect the connector and cable, verify the signal remains within limits, then compare all channels for damage or drift.
Can B&R X67AI1223 directly measure current loops?
No. Use a current-input module or an approved shunt arrangement designed for the loop; do not infer current by unsuitable wiring.
What should be recorded before replacing B&R X67AI1223?
Record channel scaling, raw limits, polarity, connector labels, sensor supply, grounding and shielding, X2X position and calibration checks.