Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

X67DI1371

/ 4.9
1001 reviews | Need a Specific Revision?
B&R X67DI1371 is an IP67 X67 module with eight 24 VDC sink inputs for type 1 digital sensors for the X67 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X67DI1371
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X67DI1371

  • Manufacturer:
    B&R
  • Part Number:
    X67DI1371
  • Product Family:
    B&R X67 System
  • Product Type:
    8-channel Digital Input Module
  • Stock:
    1
  • Digital inputs:
    8, 24 VDC, sink, type 1
  • I/O connectors:
    8 × M8, 3-pin
  • X2X Link connector:
    M12, B-coded
  • I/O power connector:
    M8, 4-pin
  • Hardware input filter:
    ≤100 µs
  • Software input filter:
    1 ms
  • Input current:
    Typically 7 mA
  • Input resistance:
    Typically 3 kΩ
  • Low / high threshold:
    <5 V / >15 V
  • Sensor supply:
    0.5 A total, short-circuit protected
  • Supply voltage:
    24 VDC nominal, 18 to 30 VDC
  • Internal I/O / X2X power:
    1 W / 0.75 W
  • Degree of protection:
    IP67
  • Operating temperature:
    -25 to 60 °C
  • Storage / transport temperature:
    -40 to 85 °C
  • Dimensions:
    5.3 × 8.5 × 4.2 cm
  • Weight:
    0.17 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Sensor Connections Timing Power Application
  • Reads eight 24 VDC type 1 digital sensors
  • Uses sealed M8 field connections in an IP67 housing
  • Provides protected sensor power for distributed machine wiring

X67DI1371 is a B&R 8-channel digital input module designed for the X67 System.

The module acquires distributed digital field signals close to the machine while X2X Link carries process and diagnostic data.

Before installation or replacement, verify the complete material number, the 24 VDC type 1 sensor characteristics, M8 pinout, sensor-supply load, X2X topology, filter timing, IP67 connector sealing and machine response time.

Availability, condition, price, and shipping time for X67DI1371 are confirmed during quotation.

B&R X67DI1371 8-channel Digital Input Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Each input uses a three-pin M8 connector
  • Input thresholds and current suit documented 24 VDC type 1 sensors
  • Unused connectors require suitable sealing caps to maintain IP67 protection
  • The hardware filter is 100 microseconds or less
  • A 1 millisecond software filter also affects response time
  • Machine sequencing must include total sensor, filter and network delay
  • Sensor power is limited to 0.5 amperes total
  • The supply is short-circuit protected
  • Cable voltage drop and total connected sensor current must be checked
  • Distributed proximity and limit-switch acquisition on machine sections
  • Fast 24 VDC sensor monitoring outside the control cabinet
  • IP67 digital input islands linked to an X2X automation station
Description
X67DI1371 is a B&R 8-channel digital input module for the X67 System.

It provides eight M8 sensor connections, a hardware filter of 100 µs or less, a 1 ms software filter and a protected 0.5 A sensor supply.

Before installation or replacement, confirm the complete material number, the 24 VDC type 1 sensor characteristics, M8 pinout, sensor-supply load, X2X topology, filter timing, IP67 connector sealing and machine response time.
Alternative Names
X67DI1371 X67 DI1371 B&R X67DI1371 B&R X67 DI1371 BR X67DI1371 B&R X67 System X67DI1371 X67 System X67DI1371
Technical notes
X67DI1371 is an IP67 field module. Confirm M8 sensor pinout, 24 VDC type 1 input compatibility, sensor-supply current, X2X wiring, filter delay and sealed connector condition before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can B&R X67DI1371 power all eight connected sensors?
Only if their combined current, including startup demand, stays within the 0.5 A sensor-supply limit and cable voltage drop remains acceptable.
Why does B&R X67DI1371 show an unstable input?
Check sensor type, 24 VDC stability, connector contamination, cable damage, common reference, switching threshold, EMC routing and mechanical vibration.
Can B&R X67DI1371 be used for safety inputs?
No. It is a standard digital input module; safety functions require an approved safety-rated input module and validated architecture.
How fast can B&R X67DI1371 detect a signal change?
Include the sensor response, hardware filter of 100 µs or less, 1 ms software filter, X2X cycle and controller task time in the complete response calculation.
What is required to retain IP67 protection on B&R X67DI1371?
Use compatible sealed connectors, tighten them correctly, cap every unused port and inspect seals, cable jackets and housing surfaces.
Can B&R X67DI1371 replace another eight-input X67 module directly?
Do not assume so; compare input type, connector pinout, filter behavior, sensor-power rating, diagnostics, X2X project mapping and mechanical installation.
What should be recorded before replacing B&R X67DI1371?
Record X2X node and project position, connector labels, sensor types, cable routing, power load, filter timing and active diagnostics.