Features:
- The 1/4-28 UNF body combines a 0.4 in unthreaded tip with a 2.4 in case.
- A 1.0 m unarmored lead ends in a miniature coaxial ClickLoc connector without a protector.
- The matched NSv system provides a 1.5 mm linear measurement range around the selected target gap.
Bently Nevada 330901-04-24-10-02-05 brings the sensing tip to the target through a compact threaded case.
The integral lead of 330901-04-24-10-02-05 transfers the probe response to the extension-cable connection without an armored sheath.
The extension cable and Proximitor Sensor complete the calibrated NSv electrical length outside the probe.
The Bently Nevada 330901-04-24-10-02-05 3300 XL NSv 1/4-28 Proximity Probe may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330901-04-24-10-02-05 3300 XL NSv Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Threaded Probe Geometry
- Tip: The sensing section begins with 0.4 in of unthreaded length.
- Case: The complete case length is 2.4 in.
- Thread: A 1/4-28 UNF thread holds the probe at the selected axial position.
- Engagement: Thread engagement must not extend beyond the documented case limit.
Unarmored Lead Handling
- Length: The integral probe cable is 1.0 m long.
- Armor: No metal armor surrounds the cable jacket.
- Bend: Routing must retain at least the documented 25.4 mm bend radius.
- Strain: Clamps should support the cable without transferring pull to the probe or connector.
ClickLoc Signal Junction
- Interface: The lead terminates in a miniature coaxial ClickLoc connector.
- Protector: This option does not include a connector protector.
- Seating: The mating connector must lock fully before the transducer loop is checked.
- Protection: The installed route must shield the exposed connector from contact and contamination.
NSv Measurement Path
- Gap: A 1.0 mm initial gap places the target near the specified operating point.
- Range: The matched system provides 1.5 mm of linear measurement.
- Scale: Target motion changes the conditioned output at 7.87 V/mm.
- Bandwidth: The transducer response extends from 0 to 10 kHz.