Technical specifications for 89477-25

  • Manufacturer:
    Bently Nevada
  • Part Number:
    89477-25
  • Product Family:
    330500 Velomitor Piezo-velocity Sensor
  • Cable Type:
    Right-Angle Interconnect Cable
  • Cable Length:
    25 feet
  • Maximum Sensor Head Temperature:
    +400°C (+752°F)
  • Internal Electronics Temperature Range:
    -55°C to +121°C (-67°F to +250°F)
  • Recommended Use:
    High-temperature vibration monitoring applications
  • Weight:
    0.1 kg
  • Estimated shipping dimensions:
    25x25x3cm
  • Tariff Code:
    8525891900
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.
Description
The 89477-25 right-angle interconnect cable is an integral component of High Temperature Velomitor Systems, engineered to operate reliably in environments where surface temperatures reach up to +400°C (+752°F). This 25-foot cable permanently connects the high-temperature sensing head to the signal conditioning electronics, allowing the sensitive electronics to be positioned in a cooler location while the sensor remains mounted on hot surfaces. 

The 89477-25 is specifically designed to segregate the sensing element from the signal conditioning electronics, a critical feature for maintaining accurate vibration measurements in extreme thermal conditions. This segregation ensures that the internal electronics, which are rated for temperatures from -55°C to +121°C (-67°F to +250°F), remain within their operational limits even when the sensing head is exposed to much higher temperatures.

When deploying the 89477-25, it is important to note that the cable is permanently integrated into the transducer assembly, which reduces maintenance complexity and improves signal integrity over traditional connector-based systems. 

Installation of the 89477-25 requires careful planning to ensure the cable is routed away from heat sources and protected from physical damage, while also maintaining proper signal transmission characteristics. The right-angle connector design helps in confined spaces and reduces stress on the cable termination points. 
Alternative Names
89477-32 89477-20 89477-07 89477-40
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the primary function of the 89477-25 cable in high-temperature vibration monitoring systems?
The 89477-25 serves as a permanent, integrated interconnect cable that connects the high-temperature sensor head (rated for up to +400°C / +752°F) to the signal conditioning electronics in Bently Nevada's 330750/330752 Velomitor Systems. Its 25-foot length and connectorless design enable reliable signal transmission while allowing the electronics to be mounted in cooler locations.
How does the 89477-25 improve reliability in high-temperature environments compared to traditional cabled sensors?
The 89477-25 eliminates connectors, which are common failure points in high-temperature applications, by using a permanently integrated cable design. It also separates the sensing element from the electronics, ensuring that the internal components (rated for -55°C to +121°C) remain within safe operating temperatures even when the sensor head is exposed to extreme heat up to +400°C.
What are the temperature limits for the sensor head and internal electronics when using the 89477-25?
When used with the 89477-25 in a 330750/330752 system, the sensor head can operate at temperatures up to +400°C (+752°F), while the internal signal conditioning electronics are limited to -55°C to +121°C (-67°F to +250°F). This thermal segregation is enabled by the 89477-25 cable, which allows the electronics to be installed in a cooler environment.
When should I choose a system with the 89477-25 cable versus a standard Velomitor sensor?
The 89477-25 and its associated high-temperature Velomitor system should be selected when the mounting surface temperature exceeds +121°C (+250°F), up to the maximum of +400°C. For environments at or below +121°C, the standard 330500 Velomitor Piezo-velocity Sensor is recommended, as it does not require the specialized high-temperature design of the 89477-25 system.