Bently Nevada 172109-01 is the 3500/65 RTD/isolated-tip thermocouple I/O module with external terminations for temperature monitoring systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 172109-01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 172109-01

  • Manufacturer:
    Bently Nevada
  • Part Number:
    172109-01
  • Product Family:
    3500 System
  • Product Type:
    3500/65 RTD/Isolated Tip TC I/O Module, External Terminations
  • Stock:
    1
  • Termination Type:
    External
  • Supported Inputs:
    RTD and isolated-tip thermocouple
  • Input Capacity:
    Up to 16 signals with 3500/65 monitor
  • Input Impedance:
    Greater than 1 MΩ per lead
  • RTD Current:
    913 ± 7 µA at 25°C
  • Operating Temperature:
    -30°C to +65°C
  • Dimensions:
    241.3 x 24.4 x 99.1 mm
  • Weight:
    0.45 kg
  • Rack Space:
    1 full-height rear slot
  • Weight:
    0.45 kg
  • Estimated shipping dimensions:
    2.5x11x24cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Terminations Compatibility Replacement
  • Part number: 172109-01
  • Module: 3500/65 RTD/Isolated Tip TC I/O Module
  • Termination: External
  • Supported inputs: RTD and isolated-tip thermocouple
  • Rack location: One full-height rear slot

Use the official Bently Nevada 3500/65 16-Channel Temperature Monitor Datasheet, document number 172930, to verify specifications, ordering options and replacement instructions.

Confirm the module revision and monitor firmware before installation.

  • Input capacity: Up to 16 signals with the 3500/65 monitor
  • Input impedance: Greater than 1 MΩ per lead
  • RTD current: 913 ± 7 µA at 25°C
  • Operating temperature: -30°C to +65°C
  • Dimensions: 241.3 x 24.4 x 99.1 mm
  • Weight: 0.45 kg
  • Rack space: One full-height rear slot
  • External termination block: 172115-01, ordered separately
  • External termination cable: 134544-AAAA-BB, ordered separately
  • External termination blocks cannot be used with an internal termination I/O module
  • Verify cable length and installed termination hardware before ordering
  • Designed for the Bently Nevada 3500/65 16-channel temperature monitor
  • Supports RTD and isolated-tip thermocouple inputs
  • Four-wire RTDs require modification 179952-01
  • Confirm sensor type, I/O revision and monitor firmware before replacement
  • Identify the installed I/O revision before replacement
  • For 172109-01 Revision D or later, remove the I/O module before upgrading the monitor firmware
  • Reinstall only after completing the official firmware procedure
  • Failure to follow the procedure can cause an I/O mismatch or 562 ADC failure indication
Description
The Bently Nevada 172109-01 is the 3500/65 RTD/isolated-tip thermocouple I/O module with external terminations. It is used with the 3500/65 16-channel temperature monitor to interface RTD and isolated-tip thermocouple signals. The external termination block 172115-01 and cable 134544-AAAA-BB are ordered separately. External termination blocks cannot be used with an internal termination I/O module. Four-wire RTDs require modification 179952-01. When replacing an older module with 172109-01 Revision D or later, follow the official firmware upgrade procedure and remove the I/O module before upgrading the monitor firmware.
Alternative Names
172109 01 17210901 Bently Nevada 172109-01 BN 172109-01 3500/65 172109-01
Technical notes
Bently Nevada 172109-01 is the 3500/65 RTD/isolated-tip thermocouple I/O module with external terminations. Confirm the external termination block, cable, sensor type and firmware procedure before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is Bently Nevada 172109-01?
It is the 3500/65 RTD/isolated-tip thermocouple I/O module with external terminations.
Which sensors does 172109-01 support?
It supports RTD and isolated-tip thermocouple inputs when used with the 3500/65 temperature monitor.
Are the external termination block and cable included with 172109-01?
The official ordering information lists external termination block 172115-01 and cable 134544-AAAA-BB as separately ordered items.
Can an external termination block be used with an internal termination I/O module?
No. The official datasheet states that external termination blocks cannot be used with an internal termination I/O module.
What is required for four-wire RTD inputs?
Four-wire RTDs require modification 179952-01.
Is there a special replacement procedure for Revision D or later?
Yes. When replacing an older module with 172109-01 Revision D or later, remove the I/O module before upgrading the 3500/65 monitor firmware, following the official procedure.
Which document and details are needed for a quotation?
Refer to the official 3500/65 16-Channel Temperature Monitor Datasheet, document 172930. Provide the exact part number, revision, termination block, cable, sensor type, nameplate photos, condition and quantity.