Features:
- Integrated 8 mm probe and Proximitor sensor
- 265 mm direct-mounted penetration sleeve
- IP66/Type 4X protected housing
Bently Nevada
330881-28-00-265-00-02 places the proximity probe and conditioning electronics in one self-contained metric PROXPAC XL assembly.
Without a standoff, the 265 mm sleeve of
330881-28-00-265-00-02 sets the main reach from the mounting interface to the monitored target.
Field wiring enters
330881-28-00-265-00-02 directly, so the installer must complete conduit hardware and sealing for the selected wiring method.
The Bently Nevada 330881-28-00-265-00-02 metric PROXPAC XL proximity transducer assembly may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330881-28-00-265-00-02 metric PROXPAC XL proximity transducer assembly Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Internal Probe and Signal Conditioning
- Internal sensor: The Proximitor sensor is installed inside the protected housing.
- Direct wiring: Shielded field conductors connect the internal sensor to the monitor.
- Extension cable: No separate probe-to-Proximitor extension cable is used.
- Signal path: Probe gap is converted into the conditioned voltage delivered to the monitor input.
Penetration and Mounting Interface
- Standoff: No standoff adapter is included.
- Penetration: The sleeve provides 265 mm of coded probe penetration.
- Mounting thread: The assembly anchors through a 3/4-14 NPT outer-sleeve interface.
- Adjustment: The threaded sleeve retains final probe-position adjustment after mounting.
Gap and Dynamic Response
- Linear range: The calibrated measurement span is 2 mm.
- Nominal gap: The recommended center setting is 1.27 mm.
- Scale factor: The configured system uses a 7.87 V/mm scale factor within the stated tolerance.
- Frequency response: The specified response extends from 0 to 10 kHz.
Field Entry and Sealing
- Supplied items: The no-fitting option includes two plugs and two washers.
- Fitting choice: Conduit hardware must be selected for the installed wiring method.
- Wire size: Field terminals accept conductors from 0.2 to 1.5 mm².
- Sealing: Entry hardware must preserve the IP66/Type 4X enclosure rating.